Table
Issue | Likely Causes to Check Corrective Actions |
S100 rom option not visible during S300 controller use in the system.
S100 and S300 co- existence in the same system is not supported. S100 option rom becomes disabled when S100 and S300 are available.
Remove S300 adapter and reboot system to select F1 and select RAID for boot BIOS.
The S100 rom option appears during POST boot.
NOTE: If both controllers are used in the system, the windows driver manager displays the additional driver.
Virtual Disk-Related Errors
Use the information on the following tables as guidelines for troubleshooting the controller.
Table
Likely Causes to Check | Corrective Actions |
|
|
The physical disk is not | This error might be because: |
displayed | – The controller cannot communicate with the |
| physical disks. |
| – A cable might be loose or defective. |
| |
| check their cables. |
|
|
Insufficient free space available | There must be sufficient available free space on the |
on the selected physical disks | physical disk(s) used by the virtual disk. |
|
|
Incorrect number of physical | See "Understanding RAID Levels" in the RAID |
disks selected for the desired | Technology Guide, located on the Dell Support |
RAID level | website at support.dell.com/manuals, for a |
| description of RAID levels and the allowable |
| number of physical disks used with each RAID |
| level. |
70
Troubleshooting