The valid options for printer Port Settings are shown below. The default values are shown in bold.
Baud rate | 1200, 2400, 4800, 9600, 19200 |
Word length | 7 or 8 |
Stop bits | 1 or 2 |
Parity | Odd, Even, None |
Flow control | None, Xon/Xoff, DTR, CTS |
Reset | Yes or No |
Error Description/Action
409Printer memory is full.
410Parity mismatch.
411Framing error (baud rate mismatch).
412Flow control mismatch.
413Receive buffer is full. Check flow control settings.
414Internal keyboard buffer is full or you need a new keypad.
427Format name must be 1 to 8 characters inside quotes or a
428Batch name is invalid or graphic not found.
429A field number appears more than once in a format.
430The format uses a graphic file that cannot be found.
433The batch references a field number that does not exist in the format.
497Error occurred during the parallel port loop back test.
499Error occurred during the serial port loop back test.
11 - 10 Troubleshooting