7193 Owner’s Guide | Commands |
Align Character Positions
Specifies the alignment of characters, graphics, logos, and bar codes (see table). It is valid only at the beginning of a line.
Hex | Decimal | ASCII | Value of n | Default | |
1B 61 n | 27 97 n | ESC a n | 0 | (Left Aligned) | 0 |
|
|
| 1 | (Center Aligned) |
|
|
|
| 2 | (Right Aligned) |
|
Select Sensors to Stop Printing
This command is not implemented and is ignored if received.
Hex | Decimal | ASCII |
1B 63 34 n | 27 99 52 n | ESC c 4 n |
Enable or Disable Panel Switch
Toggles the panel switches on and off. Functions that require the panel switches cannot be used when the panel switches are disabled with this command.
Hex | Decimal | ASCII | Value of n | Default | |
1B 63 35 n | 27 99 53 n | ESC c 5 n | 0 | = Enable | 0 |
|
|
| 1 | = Disable |
|
Print and Feed n Lines
Prints one line from the buffer and feeds paper n lines at the current line height.
Hex | Decimal | ASCII | Value of n |
1B 64 n | 27 100 n | ESC d n |