7193 Owner’s Guide | Communication |
DIP Switch Settings for
Switch | Settings |
| Description |
1 | OFF |
| |
| ON |
| Level 1 Diagnostics: Setup Mode |
2 | OFF |
| DTR/DSR Protocol (Default) |
| ON |
| XON/XOFF Protocol |
3 | OFF |
| Parity Disabled (Default) |
| ON |
| Parity Enabled |
4 | OFF |
| Odd Parity |
| ON |
| Even Parity |
5, 6 | 5 | 6 |
|
| OFF | OFF | 19,200 Baud |
| ON | OFF | 9600 Baud (Default) |
| OFF | ON | 4800 Baud |
| ON | ON | 1200 Baud |
Note: The following options are set with the printer in the setup mode. See “Level 1 Diagnostics” in the “Diagnostics” chapter for more information.
DIP Switch Settings for Data Error and Data Buffer Options (Choose one from each option)
Switch 1 | Switch 2 | Switch 3 | Switch 4 | Switch 5 | Switch 6 | Option |
On | Off | On | Off | Off | Off | “?” for Data Errors* |
On | Off | On | Off | Off | On | Ignore Data Errors |
On | Off | On | Off | On | Off | 4K Byte Data Buffer* |
On | Off | On | Off | On | On | One Line Data Buffer |
|
|
|
|
|
|
|
*Default |
|
|
|
|
|
|
May 1996