CHAPTER 2
2.2.7 Starting the Cleaning Cycle
As noted in Section 2.2, the right two panel LEDs flash when the time for a Cleaning Cycle arrives. Until performed, normal operations cannot continue. While the flashing occurs at card count intervals determined by a printer command (see Programmer's Manual), users can initiate a Cleaning Cycle at any time. Each Cleaning Cycle resets the card counter that triggers the
Step 1. While leaving power on, remove both plastic card and ribbon media. Note that a Cleaning cycle cannot occur with ribbon installed and that the Card Feed Hopper must not contain anything other than a Cleaning Card.
Step 2. Either place an
Step 3. Press and hold the Panel Button until the feed begins. Repeat this process with fresh Cleaning Cards for additional cleaning when desired. Before continuing, allow the alcohol to dry (one or two minutes).
Step 4. Replace the Cleaning Roller (see Sections 1.5 through 1.7), and return the printer to normal operation by installing ribbon and plastic card media and returning the Card Gate opening to a proper setting.