Sunway NT 4000 Connection to PC via RS 485/RS, Stripped length 11 mm Jumper JP400 see above

Page 41

(3) PV system for 2 to 99 solar inverters with interface converter (IC)

PV

PV

INVERTER

(1)

INVERTER

(2 to 99)

RS 485

RS 232

PC

I C

 

Connection to PC via RS 485/RS 232

RS 485–

RS 485–

RS 485+

RS 485+

RX2

TX2

GND_G

RX

TX

GND_G

RS 485–

RS 485–

RS 485+

RS 485+

(3)Up to 99 solar inverters can be con- nected together and read out using this connection. In this case, there is a maxi-

117 mum cable length of 500 m between

In order to connect several solar inverters to a PC, the RS 485 signal is looped through from inverter to inverter, until it is led into the inter- face converter. From here, the RS 232 signal is conducted to the PC. Jumper JP400 is connected to the solar inverter that is furthest away from the interface converter. It must be open for all other solar inverters.

Stripped length: 11 mm

Jumper JP400: see above

the interface converter and the furthest solar inverter. The individual solar inverters are connected together via the RS 485 interface.

Image 41
Contents Solar Inverters NT 2600, NT 4000 Manual180 mm 300 mm 510 mm Information on installation List of Contents General informationInformation on operation CommissioningAppendix General information General safety information Opening the unit Scope of supply Inspecting the deliveryPage Standard components of a PV system PV generator switchStandard components of the PV system SensorEN Mains fuse Energy meterProtection concept Information on installation Mechanical safety Information on cleaning Warm Air 300 mm 150 mm Cool · Protection from damp and foreign bodies · Thermal interactionFig. Inlets on the unit underside Electrical connection and cable entryGrid connection Three-phase grid connection distributed over three unitsPage · Connection PV generator connection · PreparationImportant information Page Communication connections · Connection Connecting the sensors · Optional irradiation sensor Page Switching the solar inverter on and off · Switching on · Switching off Configurations Plus Minus ESC/CUR UP/DWN Save Structure and menu levels for configurationLanguage LCD Contrast Software Information on operation Line DisplayData memory Sunways NT Monitor software Initialising the remote modem Connection to PC via RS Connection and circuitry optionsConnection to modem via RS Individual PV system with modem for remote inquiryStripped length 11 mm Jumper JP400 see above Connection to PC via RS 485/RSInverter to299 Connection to modem via RS 485/RS Pole Signal cables Configuring the interface cablesCable type B Connector To modem Pole Signal cables Cable type a FemaleLocating jumper JP400 in the Sunways Solar Inverter Cable type C Connector To modem PoleConverter Sunways NT Monitor data acquisition · Online values · Fault data· Monthly values · 15 minute values· Data menu · Setting menuOperation of Sunways NT Monitor · Help menu Line Error UAC3 Undervoltage Line Error UAC3 OvervoltageLine Error UAC1 Overvoltage Line Error UAC1 UndervoltageLine Error Temp Overtemperature Line Error UDC OvervoltageLine Error AFI Residual current UDC Fault diagnosis Fault display CausesUAC3 Fault display CausesAFI · Conditions · Warranty period· Exclusion of liability Appendix Designation Description Subject and abbreviation indexDesignation · DC and AC filters Functional principle and explanations· Differential measurement · Solar inverter with Heric technology· LCD display · Microcontroller· RS 485 and RS 232 interfaces · Sensor interface· MPP control PV-GENERATOR Block diagramAFI Solar Inverter NT Technical data ModelSolar Inverter NT Page Page Page Page 146 147 148 149 Registered trademarks General exclusion of liabilityPage Sunways AG Photovoltaic Technology Macairestraße 3