Uniden BC785D manual Programming Tips, Assigning the Beep Alert to a Channel

Page 33

 

numbers and punctuation marks.

 

 

6.

After entering the desired text, press E.

 

 

Remember! To clear a mistake while entering the letters, press

.

(decimal key)

repeatedly until the display is cleared.

Beep Alert

The scanner can alert you with three beeps at the beginning of a transmission on an assigned frequency.

Assigning the Beep Alert to a Channel

This alert can be set ON/OFF for every channel in Conventional mode.

In conventional mode -

1.Press MENU.

2.Select 2:SCAN OPTION / 1:CONVENTIONAL by rotating the VFO and pressing E.

3.Select the channel number by rotating the VFO and pressing E. (You can also enter the channel number by using the keypad and then press E.)

4.Select 4:BEEP ALERT by rotating the VFO and pressing E.

5.Select 1:ON or 2:OFF by rotating the VFO and pressing E.

Note: If NOT REGISTERED appears, make sure a frequency is stored in the channel.

Remember! You can also use or instead of rotating the VFO. Also instead of pressing E, you can press the VFO control.

Programming Tips

Do not program a weather frequency into one of the channels, since weather channels transmit continuously. Use the Weather Search feature to select the weather information band.

Group similar services into a bank. For example, program police frequencies in channels 1 through 10 and fire/emergency into channels 51 through 60, and so on.

Put the frequency that you listen to the most or the most important frequency into a Priority channel.

To quickly program a series of channels, start with the lowest number channel.

For example, when you are programming five new frequencies into channels 4 through 8, start with channel 4. After you finish programming a channel, rotate the VFO up or press to go to the next higher channel.

Write down your programmed channels and frequencies and put them in a convenient place in case of accidental reprogramming.

Frequencies are rounded off according to the step of each channel.

When you are overwriting a tagged channel with a new frequency, the previous alpha tag will be deleted. You must re-enter the alpha tag.

When programming frequencies, a 2 second delay is set automatically but can be changed in the menu mode.

29

Image 33
Contents Page Page Contents Edacs Scat LTR IntroductionBC785D Front and Rear ViewIcon Description BC785D Shortcuts Entered. To begin Searching between the Range, press Srch Important Notice What is Searching? What is Scanning?What is Trunk Tracking? TerminologyWhat is Apco Project 25 Digital Communications? Feature Highlights Where to Obtain More Information Information on the InternetScanner.uniden.com Included with Your Scanner Package Connecting an Antenna SetupMounting an Antenna Optional AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Applying Power Using Standard AC Power Desktop InstallationConnecting an External Speaker Connecting an EarphoneConnecting the Tape Recorder Connecting the Clone CableListening Safely RememberSetting the Squelch Basic OperationTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents Set attenuation for all search ranges 2DELAY You can assign a variety of step sizes to the channel 9I-CALLMOTOROLA/EDACS Allows you to change the brightness of the display 6CLONE Programming Storing Frequencies into Channels in Menu Mode001 1FREQUENCY010 512.0000 NFM Error OUT of ChannelOUT of Band C1000 0000.0000Storing Text Tags Transfer FrequenciesAssigning a Bank Tag to a Bank Assigning a Text Tag to a ChannelBeep Alert Programming TipsAssigning the Beep Alert to a Channel To directly access a specific channel Scan Hold FeatureScanning ScanSetting the Delay Mode for Frequency RF Attenuation FeatureStoring Frequencies During Scanning During ScanningLockout in Hold Mode 001 141.5000 NFM Uniden Group aChannel Lockout Lockout in Scanning Mode Restoring a Locked-out ChannelRestoring All Locked-out Channels Priority on Error PRI CH Lockout010 1240.0000 NFM 001 512.0000 NFMPriority Channel Plus Scan Setting a Search Range SearchingSrch 12.5k Srch 12.5k 1240.0000 NFM Range 25cm Amateur Grp Search Hold FeatureStarting Chain Search Data SkipSrch 12.5k 1240.0000 NFM Range C004 Frequency SkipStoring Search Frequencies Auto Store ErrorSelect Bank CH Data FullFor Search mode, select 1SERVICE Option / Chain Search 003 512.0000 NFM Ctcss Uniden Group a 001 512.0000 NFM Ctcss 250.3 Bank003 Additional Menu Options for Searching2PUBLIC Safety 3NEWS Service SearchNWR-SAME Alert Service Search SkipTesting the Alert Siren Fips CodeProgramming Fips Code Digital and Trunked Systems Programming and Receiving Digital and Trunked Systems 001 OOOO.0000Selecting or Changing Trunking System Type Programming Trunking Frequencies 010Programming ID Scan Lists Manually Enter ID M5-0 4128 1216¡M5-0 050-2¡ E5-0 09-022¡M5-0 1216 Enter Alpha TAGReceiving Trunked Systems ID Scan Hold Feature ID Scan ModeM1-14128 867.8375 NFM ID Tag List Tag C1000 0000.0000 Bank Trunked SearchID Search Hold and Direct Entry ID Hold Mode ID Monitor ModeM1-14128 MOT ID8192ID Review LT ID0-02-042Review ID Lockout Restoring Locked-out IDsSetting Priority in Trunking Mode Setting the Delay Mode for Trunking ModeID tag Bank04 MOT TYP2 Programming Scan Lists During SearchDeleting a Stored ID MOT ID LIST01 No.01 M1-1 851.0375 NFMMoving between Scan List Memories Call Motorola/EDACSTalkgroups Multi-TrackMulti-Track Operational Details Edacs Tracking Edacs ReceptionAn Edacs Trunked system Special Edacs FeaturesEmergency Call Alert Edacs Scat LTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionNFM Select Fleet MAP Preset 001 867.8375 NFM1TYPE2 Programming a Hybrid System NFM Block 0 Size CodeControl Channel Only Mode 50.0Toggling the Status Bit Disconnect Tone Detect Option End Code Apco Project 25 Reception Installing the Apco P-25 cardTurning ON/OFF the Apco P-25 Card Precautions for Installing the BCi25D CardThreshold Adjustment Range Apco P-25 Sound Quality Fine TuningSound QULTY0050 867.8375 P25 Low Mid Upp 0533 1985Page Remote Interface PC Control ModeTo connect Scanner to PC To program your scannerStart Remote Mode and Change Transfer Speed Clone ModeSpeed 39600 bps 419200 bps 5OFF Scanner.uniden.com PC Control ParameterTo connect the Scanner to Scanner Clone Clone Master Unit Slave UnitDimmer Additional FeaturesEnter Lock Key Beep OptionReceiving Mode Selection Reverse ModeFrequency and Channel Tuning with the VFO Control Channel Step SelectionCare and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesNWR-SAME Event Code Reverse List DCS Tone Code Ctcss Frequency List HzBC785D Flow Charts Scan Option Conventional System Option Dimmer Uniden America Corporation One Year Limited Warranty