Uniden BC785D manual Reverse List

Page 94

Event Code

Standard

Event Level (Siren Type)

 

LCD Display

 

 

Warning

Watch

Statement

Test

 

Severe Weather Statement

SVS

 

 

0

 

SEVERE WX

Special Weather Statement

SPS

 

 

0

 

SPECIAL WX

Flash Flood Statement

FFS

 

 

0

 

FLASH FLOOD

Flood Statement

FLS

 

 

0

 

FLOOD

Hurricane Statement

HLS

 

 

0

 

HURRICANE

National Periodic Test

NPT

 

 

 

0

NATION PERIOD

Required Monthly Test

RMT

 

 

 

0

MONTHLY

Required Weekly Test

RWT

 

 

 

0

WEEKLY

System Demonstration/ Practice

DMO

 

 

 

Note

SYSTEM DEMO

National Hazard Warning

NHW

0

 

 

 

NATION HAZARD

Unknown Emergency Tune TV

**E

0

 

 

 

UNKNOWN TV

Unknown Warning Tune TV

**W

0

 

 

 

UNKNOWN TV

Unknown Watch Tune TV

**A

 

0

 

 

UNKNOWN TV

Unknown Statement Tune TV

**S

 

 

0

 

UNKNOWN TV

REVERSE LIST

Range

Offset

Range

Offset

29.520

- 29.580

+0.1 MHz

445.000 - 449.9875

-5 MHz

29.620

- 29.680

-0.1 MHz

450.000 - 454.9875

+5 MHz

52.010

- 52.990

+1 MHz

455.000 - 459.9875

-5 MHz

53.010

- 53.990

-1 MHz

460.000 - 464.9875

+5 MHz

143.750

+4.375 MHz

465.000 - 469.9875

-5 MHz

143.900

+4.25 MHz

470.000 - 472.9875

+3 MHz

144.510

- 144.890

+0.6 MHz

473.000 - 475.9875

-3 MHz

145.110

- 145.490

-0.6 MHz

476.000 - 478.9875

+3 MHz

146.010

- 146.385

+0.6 MHz

479.000 - 481.9875

-3 MHz

146.415

- 146.505

+1 MHz

482.000 - 484.9875

+3 MHz

146.595

+1 MHz

485.000 - 487.9875

-3 MHz

146.610

- 146.985

-0.6 MHz

488.000 - 490.9875

+3 MHz

147.000

- 147.390

+0.6 MHz

491.000 - 493.9875

-3 MHz

147.415

- 147.505

-1 MHz

494.000 - 496.9875

+3 MHz

147.595

-1 MHz

497.000 - 499.9875

-3 MHz

147.600

- 147.990

-0.6 MHz

500.000 - 502.9875

+3 MHz

148.125

-4.375 MHz

503.000 - 505.9875

-3 MHz

148.150

-4.25 MHz

506.000 - 508.9875

+3 MHz

222.120

- 223.380

+1.6 MHz

509.000 - 511.9875

-3 MHz

223.720

- 224.980

-1.6 MHz

806.000 - 823.9875

+45 MHz

420.000 - 424.9875

+5 MHz

851.000 - 868.9875

-45 MHz

425.000 - 429.9875

-5 MHz

896.000 - 901.000

+39 MHz

440.000 - 444.9875

+5 MHz

935.000 - 940.000

-39 MHz

90

Image 94
Contents Page Page Contents Edacs Scat Introduction LTRFront and Rear View BC785DIcon Description BC785D Shortcuts Entered. To begin Searching between the Range, press Srch Important Notice What is Trunk Tracking? What is Scanning?What is Searching? TerminologyWhat is Apco Project 25 Digital Communications? Feature Highlights Information on the Internet Where to Obtain More InformationScanner.uniden.com Included with Your Scanner Package Mounting an Antenna SetupConnecting an Antenna Optional AntennaTypical Mounting Methods Mounting the Scanner in Your VehicleApplying Power for Vehicle Installation Connecting an External Speaker Desktop InstallationApplying Power Using Standard AC Power Connecting an EarphoneListening Safely Connecting the Clone CableConnecting the Tape Recorder RememberBasic Operation Setting the SquelchTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents Set attenuation for all search ranges 2DELAY You can assign a variety of step sizes to the channel 9I-CALLMOTOROLA/EDACS Allows you to change the brightness of the display 6CLONE 001 Storing Frequencies into Channels in Menu ModeProgramming 1FREQUENCYOUT of Band Error OUT of Channel010 512.0000 NFM C1000 0000.0000Assigning a Bank Tag to a Bank Transfer FrequenciesStoring Text Tags Assigning a Text Tag to a ChannelProgramming Tips Beep AlertAssigning the Beep Alert to a Channel Scanning Scan Hold FeatureTo directly access a specific channel ScanStoring Frequencies During Scanning RF Attenuation FeatureSetting the Delay Mode for Frequency During Scanning001 141.5000 NFM Uniden Group a Lockout in Hold ModeChannel Lockout Restoring a Locked-out Channel Lockout in Scanning ModeRestoring All Locked-out Channels 010 1240.0000 NFM Error PRI CH LockoutPriority on 001 512.0000 NFMPriority Channel Plus Scan Searching Setting a Search RangeSrch 12.5k Starting Chain Search Search Hold FeatureSrch 12.5k 1240.0000 NFM Range 25cm Amateur Grp Data SkipFrequency Skip Srch 12.5k 1240.0000 NFM Range C004Storing Search Frequencies Select Bank ErrorAuto Store CH Data FullFor Search mode, select 1SERVICE Option / Chain Search 003 001 512.0000 NFM Ctcss 250.3 Bank003 512.0000 NFM Ctcss Uniden Group a Additional Menu Options for SearchingService Search 2PUBLIC Safety 3NEWSService Search Skip NWR-SAME AlertFips Code Testing the Alert SirenProgramming Fips Code Digital and Trunked Systems 001 OOOO.0000 Programming and Receiving Digital and Trunked SystemsSelecting or Changing Trunking System Type 010 Programming Trunking FrequenciesProgramming ID Scan Lists Manually M5-0 050-2¡ M5-0 4128 1216¡Enter ID E5-0 09-022¡Enter Alpha TAG M5-0 1216Receiving Trunked Systems M1-14128 867.8375 NFM ID Tag List Tag C1000 0000.0000 Bank ID Scan ModeID Scan Hold Feature Trunked SearchM1-14128 ID Monitor ModeID Search Hold and Direct Entry ID Hold Mode MOT ID8192Review ID Lockout LT ID0-02-042ID Review Restoring Locked-out IDsID tag Bank04 MOT TYP2 Setting the Delay Mode for Trunking ModeSetting Priority in Trunking Mode Programming Scan Lists During SearchMoving between Scan List Memories MOT ID LIST01 No.01 M1-1 851.0375 NFMDeleting a Stored ID Call Motorola/EDACSMulti-Track TalkgroupsMulti-Track Operational Details Edacs Reception Edacs TrackingSpecial Edacs Features An Edacs Trunked systemEmergency Call Alert Edacs Scat LTR Reception LTR TrackingMotorola Reception Motorola Tracking001 867.8375 NFM NFM Select Fleet MAP Preset1TYPE2 NFM Block 0 Size Code Programming a Hybrid System50.0 Control Channel Only ModeToggling the Status Bit Disconnect Tone Detect Option End Code Installing the Apco P-25 card Apco Project 25 ReceptionPrecautions for Installing the BCi25D Card Turning ON/OFF the Apco P-25 CardSound QULTY0050 Apco P-25 Sound Quality Fine TuningThreshold Adjustment Range 867.8375 P25 Low Mid Upp 0533 1985Page To connect Scanner to PC PC Control ModeRemote Interface To program your scannerSpeed 39600 bps 419200 bps 5OFF Clone ModeStart Remote Mode and Change Transfer Speed Scanner.uniden.com PC Control ParameterTo connect the Scanner to Scanner Clone Master Unit Slave Unit CloneEnter Lock Additional FeaturesDimmer Key Beep OptionFrequency and Channel Tuning with the VFO Control Reverse ModeReceiving Mode Selection Channel Step SelectionCare and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Preset Fleet Maps AppendixPreset Map Block User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Size Code RestrictionsNWR-SAME Event Code Reverse List Ctcss Frequency List Hz DCS Tone CodeBC785D Flow Charts Scan Option Conventional System Option Dimmer One Year Limited Warranty Uniden America Corporation