Uniden BC785D manual

Page 87

Enter or modify the Tone information

Enter or modify the Trunking ID. ( this can be modified through the menu screen.)

FIPS codes - For the purpose of broadcasting weather information, the NWS (National Weather Service) has divided the United States into regions by state and county (or parish, where applicable) then assigned a 6 digit FIPS code to identify each county or parish. The first digit represents the county subdivision, the next two represents the state, and the last three digits represent the county or parish. Your scanner can receive all SAME alert signals broadcasted within about a 50-mile radius of where you install it. So if you only want to hear the counties that are nearest to your area, you can choose specifically the FIPS code of areas that you want. This lets you avoid hearing warnings that apply to an area within a 50-mile radius but not necessarily in your county or parish.

I-Call- Most communications within a trunked system are group calls where one unit (such as a dispatcher) communicates with all the units within her group (all the patrol vehicles on the east side of town, for example). The units within this group comprise what is typically known as a talkgroup. There are some communications which are direct unit-to-unit conversations where one individual converses with another individual. The call is initiated by a radio and is directed to another single radio. Within the system, no one outside of these two users hears the conversation. This call is referred to as I-Call.

Key Beep - This is another term for the tone you hear as a keypad acknowledgement beep. The default setting is on.

If you have turned the Key Beep off, you now have a silent keypad. You will not hear a tone each time you press a key.

NWR S.A.M.E. Weather Alert - In 1994, the National Oceanic and Atmospheric Administration (NOAA) began broadcasting coded signals called FIPS (Federal Information Processing System) codes along with the standard weather broadcasts for stations in your area. These codes identify an emergency and the specific geographic area (such as your county) affected by the emergency. The scanner was developed with SAME (Specific Area Messaging Encoding) technology. This allows you scanner to receive, interpret, and display the information about the codes so you can determine if the emergency might affect you area.Each FIPS code identifies a specific geographic area (defined by the National Weather Service) so your scanner sounds an alert only when a weather emergency is declared in those locations. This helps you more efficiently track the weather conditions in and around your area.

PC Control - This term is associated with the ability to program frequencies and other useful information via a computer by means of third party software. You can change the transfer speed on the scanner needed to be compatible with your PC. (See page 72)

Scan List - When you designate a bank to be a trunking bank, your scanner sets up 10 Scan Lists, which are simply list of your favorite IDs. Each list can contain up to 10 IDs, so you can store a total of 100 IDs for each trunk bank. These lists are designed to help you organize the trunking system users into categories.

Screen Mask - Screen Mask reduces the amount of information that appears on the display. Alpha tags that you have set for a channel along with a few function icons will appear only on the display. This mode is particularly useful in public safety vehicles where that are already overloaded with information. Screen Mask does not work in Search mode.

83

Image 87
Contents Page Page Contents Edacs Scat LTR IntroductionBC785D Front and Rear ViewIcon Description BC785D Shortcuts Entered. To begin Searching between the Range, press Srch Important Notice Terminology What is Scanning?What is Searching? What is Trunk Tracking?What is Apco Project 25 Digital Communications? Feature Highlights Where to Obtain More Information Information on the InternetScanner.uniden.com Included with Your Scanner Package Optional Antenna SetupConnecting an Antenna Mounting an AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Connecting an Earphone Desktop InstallationApplying Power Using Standard AC Power Connecting an External SpeakerRemember Connecting the Clone CableConnecting the Tape Recorder Listening SafelySetting the Squelch Basic OperationTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents Set attenuation for all search ranges 2DELAY You can assign a variety of step sizes to the channel 9I-CALLMOTOROLA/EDACS Allows you to change the brightness of the display 6CLONE 1FREQUENCY Storing Frequencies into Channels in Menu ModeProgramming 001C1000 0000.0000 Error OUT of Channel010 512.0000 NFM OUT of BandAssigning a Text Tag to a Channel Transfer FrequenciesStoring Text Tags Assigning a Bank Tag to a BankBeep Alert Programming TipsAssigning the Beep Alert to a Channel Scan Scan Hold FeatureTo directly access a specific channel ScanningDuring Scanning RF Attenuation FeatureSetting the Delay Mode for Frequency Storing Frequencies During ScanningLockout in Hold Mode 001 141.5000 NFM Uniden Group aChannel Lockout Lockout in Scanning Mode Restoring a Locked-out ChannelRestoring All Locked-out Channels 001 512.0000 NFM Error PRI CH LockoutPriority on 010 1240.0000 NFMPriority Channel Plus Scan Setting a Search Range SearchingSrch 12.5k Data Skip Search Hold FeatureSrch 12.5k 1240.0000 NFM Range 25cm Amateur Grp Starting Chain SearchSrch 12.5k 1240.0000 NFM Range C004 Frequency SkipStoring Search Frequencies CH Data Full ErrorAuto Store Select BankFor Search mode, select 1SERVICE Option / Chain Search Additional Menu Options for Searching 001 512.0000 NFM Ctcss 250.3 Bank003 512.0000 NFM Ctcss Uniden Group a 0032PUBLIC Safety 3NEWS Service SearchNWR-SAME Alert Service Search SkipTesting the Alert Siren Fips CodeProgramming Fips Code Digital and Trunked Systems Programming and Receiving Digital and Trunked Systems 001 OOOO.0000Selecting or Changing Trunking System Type Programming Trunking Frequencies 010Programming ID Scan Lists Manually E5-0 09-022¡ M5-0 4128 1216¡Enter ID M5-0 050-2¡M5-0 1216 Enter Alpha TAGReceiving Trunked Systems Trunked Search ID Scan ModeID Scan Hold Feature M1-14128 867.8375 NFM ID Tag List Tag C1000 0000.0000 BankMOT ID8192 ID Monitor ModeID Search Hold and Direct Entry ID Hold Mode M1-14128Restoring Locked-out IDs LT ID0-02-042ID Review Review ID LockoutProgramming Scan Lists During Search Setting the Delay Mode for Trunking ModeSetting Priority in Trunking Mode ID tag Bank04 MOT TYP2Call Motorola/EDACS MOT ID LIST01 No.01 M1-1 851.0375 NFMDeleting a Stored ID Moving between Scan List MemoriesTalkgroups Multi-TrackMulti-Track Operational Details Edacs Tracking Edacs ReceptionAn Edacs Trunked system Special Edacs FeaturesEmergency Call Alert Edacs Scat LTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionNFM Select Fleet MAP Preset 001 867.8375 NFM1TYPE2 Programming a Hybrid System NFM Block 0 Size CodeControl Channel Only Mode 50.0Toggling the Status Bit Disconnect Tone Detect Option End Code Apco Project 25 Reception Installing the Apco P-25 cardTurning ON/OFF the Apco P-25 Card Precautions for Installing the BCi25D Card867.8375 P25 Low Mid Upp 0533 1985 Apco P-25 Sound Quality Fine TuningThreshold Adjustment Range Sound QULTY0050Page To program your scanner PC Control ModeRemote Interface To connect Scanner to PCScanner.uniden.com PC Control Parameter Clone ModeStart Remote Mode and Change Transfer Speed Speed 39600 bps 419200 bps 5OFFTo connect the Scanner to Scanner Clone Clone Master Unit Slave UnitKey Beep Option Additional FeaturesDimmer Enter LockChannel Step Selection Reverse ModeReceiving Mode Selection Frequency and Channel Tuning with the VFO ControlCare and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesNWR-SAME Event Code Reverse List DCS Tone Code Ctcss Frequency List HzBC785D Flow Charts Scan Option Conventional System Option Dimmer Uniden America Corporation One Year Limited Warranty