During the search of one of the preprogrammed services, the lowest display line will indicate the service that you are searching. To stop the search, press /HOLD or LIMIT /. Rotate the VFO or using or to move up or down one programmed frequency or press RSM to resume searching.

Service Search Skip

You can set the scanner to skip the unwanted frequencies during Service Search. 100 skipped frequencies are programmable.

1.To skip over a frequency, press L/O when stopping at the frequency you want to skip.

2.To cancel a skip during search, press /HOLD or LIMIT /, select the desired frequency by rotating the VFO or using or , then press L/O.

To restore all skipped frequencies, press and hold L/O for 2 seconds.

Note: • You can not skip set frequency in WEATHER Service mode.

SRVC --CH 453.6000 NFM

SERVICE SEARCH PUBLIC SAFETY

If you start the Service Searching while all frequencies in Service Search menu are set to skipped the frequencies, you hear a beep and the scanner moves to the Hold mode.

NWR-SAME Alert

In addition to the conventional weather broadcasts, your BC785D is compatible with NWR- SAME weather alert. When the scanner receives NOAA’s Specific Area Message Encoding (SAME) coded weather emergency signal, it sounds the alert siren with a specified message. You must program your FIPS code to identify the specific area where you are located.

1.Press MENU.

2.Select 1:SERVICE OPTION / 1:WEATHER / 2:ALERT by rotating the VFO and pressing E.

3.Select 1:ON by rotating the VFO or using or and pressing E.

Remember! You can also use or instead of rotating the VFO. Also instead of pressing E, you can press the VFO control.

SRVC 2CH 162.6000 FM SERVICE SEARCH WX ALERT ON

Note: You can also set Alert mode to OFF by pressing RSM without entering the Menu mode.

4.When the unit receives a warning signal, it shows a message with the alert siren defined. (For NWR-SAME EVENT CODE, see the table on page 89.)

5.To deactivate, just press any key or it is automatically canceled and the alert siren stops.

43

Image 47
Contents Page Page Contents Edacs Scat LTR IntroductionBC785D Front and Rear ViewIcon Description BC785D Shortcuts Entered. To begin Searching between the Range, press Srch Important Notice Terminology What is Scanning?What is Searching? What is Trunk Tracking?What is Apco Project 25 Digital Communications? Feature Highlights Scanner.uniden.com Where to Obtain More InformationInformation on the Internet Included with Your Scanner Package Optional Antenna SetupConnecting an Antenna Mounting an AntennaMounting the Scanner in Your Vehicle Typical Mounting MethodsApplying Power for Vehicle Installation Connecting an Earphone Desktop InstallationApplying Power Using Standard AC Power Connecting an External SpeakerRemember Connecting the Clone CableConnecting the Tape Recorder Listening SafelyTurn the Scanner On Setting the SquelchBasic Operation Understanding the Menu System Menu Description and Numeric Keypad Equivalents Set attenuation for all search ranges 2DELAY You can assign a variety of step sizes to the channel 9I-CALLMOTOROLA/EDACS Allows you to change the brightness of the display 6CLONE 1FREQUENCY Storing Frequencies into Channels in Menu ModeProgramming 001C1000 0000.0000 Error OUT of Channel010 512.0000 NFM OUT of BandAssigning a Text Tag to a Channel Transfer FrequenciesStoring Text Tags Assigning a Bank Tag to a BankAssigning the Beep Alert to a Channel Beep AlertProgramming Tips Scan Scan Hold FeatureTo directly access a specific channel ScanningDuring Scanning RF Attenuation FeatureSetting the Delay Mode for Frequency Storing Frequencies During ScanningChannel Lockout Lockout in Hold Mode001 141.5000 NFM Uniden Group a Restoring All Locked-out Channels Lockout in Scanning ModeRestoring a Locked-out Channel 001 512.0000 NFM Error PRI CH LockoutPriority on 010 1240.0000 NFMPriority Channel Plus Scan Srch 12.5k Setting a Search RangeSearching Data Skip Search Hold FeatureSrch 12.5k 1240.0000 NFM Range 25cm Amateur Grp Starting Chain SearchStoring Search Frequencies Srch 12.5k 1240.0000 NFM Range C004Frequency Skip CH Data Full ErrorAuto Store Select BankFor Search mode, select 1SERVICE Option / Chain Search Additional Menu Options for Searching 001 512.0000 NFM Ctcss 250.3 Bank003 512.0000 NFM Ctcss Uniden Group a 0032PUBLIC Safety 3NEWS Service SearchNWR-SAME Alert Service Search SkipProgramming Fips Code Testing the Alert SirenFips Code Digital and Trunked Systems Selecting or Changing Trunking System Type Programming and Receiving Digital and Trunked Systems001 OOOO.0000 Programming Trunking Frequencies 010Programming ID Scan Lists Manually E5-0 09-022¡ M5-0 4128 1216¡Enter ID M5-0 050-2¡Receiving Trunked Systems M5-0 1216Enter Alpha TAG Trunked Search ID Scan ModeID Scan Hold Feature M1-14128 867.8375 NFM ID Tag List Tag C1000 0000.0000 BankMOT ID8192 ID Monitor ModeID Search Hold and Direct Entry ID Hold Mode M1-14128Restoring Locked-out IDs LT ID0-02-042ID Review Review ID LockoutProgramming Scan Lists During Search Setting the Delay Mode for Trunking ModeSetting Priority in Trunking Mode ID tag Bank04 MOT TYP2Call Motorola/EDACS MOT ID LIST01 No.01 M1-1 851.0375 NFMDeleting a Stored ID Moving between Scan List MemoriesTalkgroups Multi-TrackMulti-Track Operational Details Edacs Tracking Edacs ReceptionAn Edacs Trunked system Special Edacs FeaturesEmergency Call Alert Edacs Scat LTR Tracking LTR ReceptionMotorola Tracking Motorola Reception1TYPE2 NFM Select Fleet MAP Preset001 867.8375 NFM Programming a Hybrid System NFM Block 0 Size CodeToggling the Status Bit Control Channel Only Mode50.0 Disconnect Tone Detect Option End Code Apco Project 25 Reception Installing the Apco P-25 cardTurning ON/OFF the Apco P-25 Card Precautions for Installing the BCi25D Card867.8375 P25 Low Mid Upp 0533 1985 Apco P-25 Sound Quality Fine TuningThreshold Adjustment Range Sound QULTY0050Page To program your scanner PC Control ModeRemote Interface To connect Scanner to PCScanner.uniden.com PC Control Parameter Clone ModeStart Remote Mode and Change Transfer Speed Speed 39600 bps 419200 bps 5OFFTo connect the Scanner to Scanner Clone Clone Master Unit Slave UnitKey Beep Option Additional FeaturesDimmer Enter LockChannel Step Selection Reverse ModeReceiving Mode Selection Frequency and Channel Tuning with the VFO ControlCare and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Appendix Preset Fleet MapsPreset Map Block Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesNWR-SAME Event Code Reverse List DCS Tone Code Ctcss Frequency List HzBC785D Flow Charts Scan Option Conventional System Option Dimmer Uniden America Corporation One Year Limited Warranty