Vanguard Managed Solutions 6500 PLUS Trim Card Spacing in a Modulus 18 Enclosure

Page 47

Installing Nodes in Modulus Enclosures

Modulus 18

Figure 2-9shows the TRIM card spacing in a Modulus 18 enclosure.

Modulus 18-Slot Nest

TRIM Card Filler Panel

6500 Node 18-Port Backplane

Top View

Slots 1 2 3

4

5 6 7

8

9 10 11 12 13 14 15 16 17 18

Note: 6500PLUS installed in left-

 

 

 

 

 

most position in Modulus

 

 

 

 

 

18. The TRIM card requires

 

 

 

 

 

two slots for its backplane.

 

 

 

 

 

TRIM

 

 

 

 

 

Card

 

 

 

 

 

 

Modulus 8/18

 

Front

 

Processor Card

 

 

 

 

Filler Panels

6500 Node 18-Port Backplane

TRIM Card Filler Panel

Note: 6500PLUS installed to the left or right of a product backplane in Modulus 18. The TRIM card requires two slots for its backplane.

Slots 1

2

3

4

5

6

7

8

9

10 11 12 13 14 15 16 17 18

Front

 

 

 

 

 

 

 

 

Processor Card

Modulus 8/18 Filler Panel

TRIM Card

Figure 2-9. TRIM Card Spacing in a Modulus 18 Enclosure

Installation

2-39

Image 47
Contents Vanguard Managed Solutions Restricted Rights Legend Restricted Rights Notification for U.S. Government UsersRadio Frequency Interference Regulations Proprietary MaterialPage Contents Contents This Chapter Describes About This ManualOverview Level Mise en gardeChapter Protocols Software FeaturesFeatures Support Cards HardwareCard Types Processor CardsEnclosure Enclosures and BackplanesStandalone Types of Modulus Supports OtherVanguardMS Products6500PLUS Processor Cards Port Configurations6525PLUS Network ConcentratorPlus Processor Card Front Panel Hardware 6500PLUS Auxiliary Processor Cards Card Type Works with Port Types Split Speed 6500PLUS Asynchronous and Universal I/O CardsAIO Card UIO CardPlus Universal I/O or Asynchronous I/O Card Front Panel NSO Card 6500PLUS Network Storage Option CardPlus Network Storage Option Card Token Ring Interface Module Trim Card 6500PLUS Token Ring Interface Module OptionHardware DSU Interface 6500PLUS Integral DSUHardware ComponentsPage Chapter Installation OverviewExample Installing Standalone UnitsUnpacking Site PreparationRear View InstallationProcedure Step Action Description/ResultStep Action Replacing Processor Cards in Standalone EnclosuresRemove the Standalone Enclosure Door Bottom of Standalone Enclosure Locking Tabs Using Screwdriver on Locking TabsPlus Processor Card with Retaining Screw Replacement CardStep Action Information Installing Nodes in Modulus EnclosuresAdditional Operation Multiprocessor NodesMultiprocessor Node ExampleAction Result/Description Replacing Master Processor of Multi-Processor NodeInstalling Nodes in Modulus Enclosures Step Action Result/Description When To Add Another Processor with Flash Before You BeginAdding a Secondary 6500PLUS Processor with Flash Revision Select Enable FlashMaintaining Current SoftwareSelect Copy Software to Flash Upgrading with Software From the New Processor CardModulus 8/18 Installing/Replacing Processor Cards Product Description Code Requirements for Installing a Trim CardTrim Card Rear Filler Panel for Modulus 8/18 Enclosures Guidelines for Installing a Trim Card in a Modulus 8/18 Trim Card Spacing in a Modulus 18 Enclosure 10. Trim Card Rear Filler Panel for Modulus 9/21 Enclosures Installing Nodes in Modulus Enclosures 11. Trim Card In Left-most Position of Modulus 21 Enclosure Plus Between Two BackplanesEnclosure Installing Nodes in Modulus Enclosures Attaching a Trim Card Installing and Connecting a Trim CardConnecting a Trim Card InstallingCables AttachingTRIM/Processor Card Removing/Replacing Trim CardsBefore Removing Trim CardsModulus 18 with Preparing Modulus Enclosures for RFI SuppressionModulus 18 RFI Installing RFISuppression Screen15. RFI Suppression Straps Modulus 18 No Trim Card No Trim CardBar Modulus 21RFI Suppression Ctp CR Starting Up the NodeNode Startup Processor Card Replacing Processor Card ComponentsReplacing DIMs New DIM RemovalJumpers 19. Jumpers on the Port Interface Pins20. Installing Jumpers on the Port Interface Pins Guidelines Installing SIMMs21. Simm Installation Replacing Flash Modules 22. Flash Module Installation Module Replacing ID ModulesChips Replacing Prom ChipsReplacing the Cmem Chip Installing the DSU DSU DIM InstallationControl Terminal Configuring the 6500PLUS for DSU Operation Output Signals DSU Input and Output SignalingInput Signals Loopback Options 24. Diagnostics MenuTroubleshooting Troubleshooting DSU DIM InstallationFacility Interface DSU DIM FCC InformationType of Interface DSU DIM Installation Event Result/Description Power-Up VerificationChecking LightsDiagnostics Power-UpNode Setting Node to Default ConfigurationInstalling Software Options Status/Statistics Select Node Stat Accessing Node Serial Number from Node StatisticsAccess Serial Number25. Serial Number on Node Stat Screen Steps Enabling a Software Access KeyConfigure Select Software Key Table Follow TheseInstall New Installing New Software Options in an Existing NetworkEnhanced LAN Option Cables Appendix aName Position Function/Signal PinFunction/Signal PinFunction Position Signal Name35/V.36 Modulus 9/21 Enclosures Function PinSignals Modulus 9/21 Enclosures 35/V.36 Signals Standalone and Modulus 8/18 Enclosures Position Name Signals Standalone and Modulus 8/18 EnclosuresPin Function Page Unit Dimensions SpecificationsPhysical Characteristics Limits Power RequirementsEnvironmental DIM IndexLL 2-69RS