Vanguard Managed Solutions 6500 PLUS Signals Standalone and Modulus 8/18 Enclosures

Page 96

V.11 Signals (Standalone and Modulus 8/18 Enclosures)

Pin

 

DCE

V.11

Function/Signal

Pi

 

DTE

Function/Signal

 

 

Position

 

Name

n

 

Position

Name

 

 

 

 

 

 

 

 

 

1

--------------

 

SHIELD/FRAME

1

-------------

SHIELD/FRAME

 

 

 

 

GROUND

 

 

 

GROUND

 

 

 

 

 

 

 

 

 

2

<------------

T

TRANSMITTED

2

-------------

TRANSMITTED

 

 

 

(A)

DATA A

 

 

 

DATA A

 

 

 

 

 

 

 

 

 

3

------------

>

R

RECEIVED DATA A

3

<------------

RECEIVED DATA A

 

 

 

(A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

<------------

C

CONTROL A

4

-----------

>

CONTROL A

 

 

 

(A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

------------

>

I (B)

INDICATION B

6

<------------

INDICATION B

 

 

 

 

 

 

 

 

 

7

--------------

 

SIGNAL GROUND

7

--------------

SIGNAL GROUND

 

 

 

 

 

 

 

 

 

8

------------

>

I (A)

INDICATION A

8

<------------

INDICATION A

 

 

 

 

 

 

 

 

 

13

-----------

>

S

TRANSMIT CLOCK

13

<------------

TRANSMIT CLOCK

 

 

 

(B)

B

 

 

 

B

 

 

 

 

 

 

 

 

 

14

<-----------

T

TRANSMITTED

14

------------

>

TRANSMITTED

 

 

 

(B)

DATA B

 

 

 

DATA B

 

 

 

 

 

 

 

 

 

15

------------

>

S

TRANSMIT CLOCK

15

<------------

TRANSMIT CLOCK

 

 

 

(A)

A

 

 

 

A

 

 

 

 

 

 

 

 

 

16

------------

>

R

RECEIVED DATA B

16

<------------

RECEIVED DATA B

 

 

 

(B)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

------------

>

*

RECEIVE CLOCK A

17

<------------

RECEIVE CLOCK A

 

 

 

 

 

 

 

 

 

18

------------

>

*

RECEIVE CLOCK B

18

<------------

RECEIVE CLOCK B

 

 

 

 

 

 

 

 

 

19

------------

>

*

RECEIVE CLOCK B

19

<------------

RECEIVE CLOCK B

 

 

 

 

 

 

 

 

 

20

<-----------

C

CONTROL B

20

------------

>

CONTROL B

 

 

 

(B)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

------------

>

S(B)

TRANSMIT CLOCK

21

<------------

TRANSMIT CLOCK

 

 

 

 

B

 

 

 

B

 

 

 

 

 

 

 

 

 

22

<-----------

X

EXTERNAL

22

------------

>

EXTERNAL

 

 

 

(B)

TRANSMIT CLOCK

 

 

 

TRANSMIT CLOCK

 

 

 

 

B

 

 

 

B

 

 

 

 

 

 

 

 

 

24

<------------

X

EXTERNAL

24

------------

>

EXTERNAL

 

 

 

(A)

TRANSMIT CLOCK

 

 

 

TRANSMIT CLOCK

 

 

 

 

A

 

 

 

A

 

 

 

 

 

 

 

 

 

*These V.11 signals are not used in the X.21 standard.

A-6

Cables

Image 96
Contents Vanguard Managed Solutions Restricted Rights Notification for U.S. Government Users Restricted Rights LegendProprietary Material Radio Frequency Interference RegulationsPage Contents Contents About This Manual OverviewThis Chapter Describes Mise en garde LevelChapter Software Features FeaturesProtocols Hardware Card TypesProcessor Cards Support CardsEnclosures and Backplanes StandaloneEnclosure Supports Other VanguardMSProducts Types of Modulus6500PLUS Processor Cards Configurations 6525PLUS NetworkConcentrator PortPlus Processor Card Front Panel Hardware 6500PLUS Auxiliary Processor Cards 6500PLUS Asynchronous and Universal I/O Cards AIO CardUIO Card Card Type Works with Port Types Split SpeedPlus Universal I/O or Asynchronous I/O Card Front Panel 6500PLUS Network Storage Option Card NSO CardPlus Network Storage Option Card 6500PLUS Token Ring Interface Module Option Token Ring Interface Module Trim CardHardware 6500PLUS Integral DSU HardwareComponents DSU InterfacePage Installation Overview ChapterInstalling Standalone Units UnpackingSite Preparation ExampleInstallation ProcedureStep Action Description/Result Rear ViewReplacing Processor Cards in Standalone Enclosures Step ActionRemove the Standalone Enclosure Door Bottom of Standalone Enclosure Using Screwdriver on Locking Tabs Locking TabsReplacement Card Plus Processor Card with Retaining ScrewStep Action Installing Nodes in Modulus Enclosures AdditionalInformation Multiprocessor Nodes MultiprocessorNode Example OperationReplacing Master Processor of Multi-Processor Node Action Result/DescriptionInstalling Nodes in Modulus Enclosures When To Add Another Processor with Flash Before You Begin Adding a Secondary 6500PLUS Processor with FlashStep Action Result/Description Select Enable Flash MaintainingCurrent Software RevisionUpgrading with Software From the New Processor Card Select Copy Software to FlashInstalling/Replacing Processor Cards Modulus 8/18Requirements for Installing a Trim Card Product Description CodeTrim Card Rear Filler Panel for Modulus 8/18 Enclosures Guidelines for Installing a Trim Card in a Modulus 8/18 Trim Card Spacing in a Modulus 18 Enclosure 10. Trim Card Rear Filler Panel for Modulus 9/21 Enclosures Installing Nodes in Modulus Enclosures 11. Trim Card In Left-most Position of Modulus 21 Enclosure Between Two Backplanes EnclosurePlus Installing Nodes in Modulus Enclosures Installing and Connecting a Trim Card Attaching a Trim CardInstalling Connecting a Trim CardAttaching CablesRemoving/Replacing Trim Cards Before RemovingTrim Cards TRIM/Processor CardPreparing Modulus Enclosures for RFI Suppression Modulus 18 withInstalling RFI SuppressionScreen Modulus 18 RFINo Trim Card 15. RFI Suppression Straps Modulus 18 No Trim CardModulus 21 RFI SuppressionBar Starting Up the Node Node StartupCtp CR Replacing Processor Card Components Processor CardReplacing DIMs Removal New DIM19. Jumpers on the Port Interface Pins Jumpers20. Installing Jumpers on the Port Interface Pins Installing SIMMs Guidelines21. Simm Installation Replacing Flash Modules 22. Flash Module Installation Replacing ID Modules ModuleReplacing Prom Chips ChipsReplacing the Cmem Chip DSU DIM Installation Installing the DSUControl Terminal Configuring the 6500PLUS for DSU Operation DSU Input and Output Signaling Input SignalsOutput Signals 24. Diagnostics Menu Loopback OptionsTroubleshooting DSU DIM Installation TroubleshootingDSU DIM FCC Information Type of InterfaceFacility Interface DSU DIM Installation Power-Up Verification CheckingLights Event Result/DescriptionPower-Up DiagnosticsSetting Node to Default Configuration NodeInstalling Software Options Accessing Node Serial Number from Node Statistics Access SerialNumber Status/Statistics Select Node Stat25. Serial Number on Node Stat Screen Enabling a Software Access Key Configure Select Software Key TableFollow These StepsInstalling New Software Options in an Existing Network Install NewEnhanced LAN Option Appendix a CablesFunction/Signal Pin Function/SignalPin Name PositionPosition Signal Name 35/V.36 Modulus 9/21 EnclosuresFunction Pin FunctionSignals Modulus 9/21 Enclosures 35/V.36 Signals Standalone and Modulus 8/18 Enclosures Signals Standalone and Modulus 8/18 Enclosures Position NamePin Function Page Specifications Physical CharacteristicsUnit Dimensions Power Requirements EnvironmentalLimits Index DIMLL 2-69RS