Series Recording Using 2 or More VR-716 Recorders

Recording using 2 or more VR-716 recorders is possible. Once the first VR-716 is full, recording automatically starts at the second VR-716.

• •

Camera1

<VR-716 1>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUDIO IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

 

16

 

 

VIDEO IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THRU OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCSI

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUDIO OUT

VIDEO OUT

 

 

 

 

 

 

 

 

 

 

 

 

RS-232C

 

UPS

LAN

1

2

1

2

 

 

 

 

 

1

4/

16

5

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(220V–240V

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIGNAL GND

 

 

 

 

 

 

 

 

 

 

 

 

ALARM

 

9

 

12

13

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EE OUT

 

 

 

 

AUDIO IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

 

16

 

 

VIDEO IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THRU OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCSI

 

 

 

 

 

 

CAUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUDIO OUT

VIDEO OUT

 

 

 

 

 

 

 

 

 

 

 

 

RS-232C

 

UPS

LAN

1

2

1

2

 

 

 

 

 

1

4/

16

5

8

AC IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(220V–240V

)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIGNAL GND

 

 

 

 

 

 

 

 

 

 

 

 

ALARM

 

9

 

12

13

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EE OUT

 

 

 

 

<VR-716 2>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection

<Connection of the Signal Input/Output Terminals>

Connect the [SERIES REC OUT] terminal at the rear panel of the first VR- 716 to the [SERIES REC IN] terminal of the second.

Connect the [CLOCK RESET OUT] terminal of the first VR-716 to the [CLOCK RESET IN] terminal of the second.

Connect the [COM] terminal of the first VR-716 to the same terminal at the second.

<Connection between the 2 VR-716 Recorders>

Camera 16

Connect the [THRU OUT] terminals 1 - 16 of the first VR-716 to the [VIDEO IN] terminals 1 - 16 of the second VR-716 accordingly.

<Signal Input/Output Terminals>

[COM]

1

 

3

 

5

 

7

 

 

9

 

11

 

13

 

15

RST

COM IN

IN

EXT REC

2

 

4

 

6

 

8

 

 

10

 

12

 

14

 

16

OUT

 

CLK

SER

 

 

 

 

 

 

 

 

 

WAR

RST

REC

COM

 

 

 

 

 

 

 

ALARM

 

 

 

 

 

OUT

OUT

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[CLOCK RESET OUT]

[SERIES REC OUT]

 

 

 

 

 

 

 

 

 

[CLOCK RESET IN]

[SERIES REC IN]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[COM]

1

3

5

7

 

9

11

13

15

RST

COM

IN

IN

EXT REC

2

4

6

8

 

10

12

14

16

OUT

 

CLK

 

SER

 

 

WAR

RST

 

REC

COM

 

 

 

 

 

ALARM

 

 

 

 

OUT

OUT

 

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

Specify the same settings for both recorders in the “REC MODE” Menu (Page 24).

In the “OPERATION” Menu, specify a value other than “NORMAL REC” for the “RECOVERY REC” item.

In the “OPERATION” Menu (Page 25) of the first VR-716, set “REPEAT REC” to “OFF”.

Set the “SERIES REC” item in the “EXT REC” Menu (Page 25) to “ON” for both recorders.

Notes

When the [CLOCK RESET OUT/IN] terminals are connected, the clock in the 2 or more VR-716 recorders will be synchronized twice a day at 12:00 am and 12:00pm.

Turn off the power of the equipment before connecting.

Recording at the second VR-716 can only be stopped by using the [STOP] button on it.

Recording will not start upon input of signals when the [OPERATE] button is in the OFF mode.

Recording will not start when in the Program Timer Standby mode.

When the power of the first VR-716 is cut off, the second VR-716 starts recording automatically.

Activation of Recording Via External Signals

While in the Stop mode, recording starts when the [EXT REC IN] terminal at the rear panel receives input signals from external devices.

[EXT REC IN]

Setting

1. Set the “EXT REC MODE” item in the “EXT REC” Menu to “TRIGGER” or “MANUAL”.

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes

1

3

5

7

9

11

13

15

RST

COM

IN

IN

EXT REC

• When this is set to “MANUAL”, recording is executed only while input

2

4

6

8

10

12

14

16

OUT

 

CLK

SER

 

WAR RST

REC

COM

signals are received.

 

 

 

 

ALARM

 

 

 

OUT

OUT

OUT

 

When this is set to “TRIGGER”, recording will continue between the interval when input signals are received until after execution of the Stop operation. Recording can only be stopped by using the [STOP] button on VR-716. Recording cannot be stopped using an external device.

Recording will not start upon input of signals when the [OPERATE] button is in the OFF mode.

Recording will not start when in the Program Timer Standby mode.