Mail Notification Setting During Alarm/Sensor Input

In a network environment where use of a mail server (SMTP) is possible, mail notification setting can be performed at VR-716 to send out the alarm list during alarm/sensor input in the form of notification messages on a regular basis.

1. Click z

1 Select a [Mode].

2 Register the [Mail (SMTP)

Server ].

3 Select an [Interval] for sending out notification messages (5, 10, 15 or 30 minutes).

4 Register the mail address of the [To E- MAIL].

5 Register the mail address of the [From E-MAIL].

6 Click [SAVE].

Upon setting, the mail notification feature can be checked to ensure that it is properly functioning.

Clicking [SAVE] at the [E-MAIL SETUP] screen displays a confirmation screen.

1 Click [TEST E-MAIL].

Click [TEST E-MAIL] to issue a test mail. Check that this mail is received at the specified destination.

When sending of notification fails due to errors in the settings or network, an error message will be displayed. Check the mail notification as well as network settings.

<Selection items for 1>

[None]:

Disables the mail notification feature.

[Alarm/Sensor]:

Sends out mail notification during alarm/ sensor input.

Notes

When using the mail notification feature, perform settings described in page 96 ‘Net- work Settings’ as well.

To use the mail notification feature, the following information must be registered.

Mode

Mail (SMTP) Server (Enter the domain name.)

Sender’s Mail Address

Minimum Mail Notification Interval

Receiver’s Mail Address

Notification mails can be sent out to mul- tiple receivers by inserting [ , ] or a space between the receivers’ mail addresses. (Maximum no. of input characters is 254)

The following is registered as the [Subject:] in the factory settings:

[Starting Alarm/Sensor REC!!] (Maximum no. of input characters is 32)

[Normal] or [Short] can also be selected from the [List Form] as the mode of mes- sage display.

Caution

Mail notification may fail depending on the authentication method at the mail server.

Consult your network administrator on the mail server’s settings.

A complete alarm/sensor list may not be received depending on the maximum no. of characters a mobile can receive.

Regardless of the interval setting of mail notification, the mail notification will be sent within 10 minutes from the first alarm/sen- sor input. It may take much time before data can be received depending on the network environment.