Vanguard Managed Solutions 6500 PLUS installation manual Function/Signal Pin, Name Position

Page 92

EIA 232-D Signals (Standalone, Modulus 8/18, and 9/21 Enclosures)

Pin

 

DCE

Function/Signal

Pin

DTE

Function/Signal

 

 

Position

Name

 

Position

Name

 

 

 

 

 

 

 

1

---------------

Shield/Frame Ground

1

---------------

Shield/Frame Ground

 

 

 

 

 

 

 

2

<-------------

TXD

2

------------->

TXD

 

 

 

 

 

 

 

3

-------------

>

RXD

3

<-------------

RXD

 

 

 

 

 

 

 

4

<-------------

RTS

4

------------->

RTS

 

 

 

 

 

 

 

5

-------------

>

CTS

5

<-------------

CTS

 

 

 

 

 

 

 

6

-------------

>

DSR

6

<-------------

DSR

 

 

 

 

 

 

 

7

---------------

Signal Ground

7

---------------

Signal Ground

 

 

 

 

 

 

 

8

---------------

DCD

8

<-------------

DCD

 

 

 

 

 

 

 

14

<-------------

DATA RESTRAINT

14

------------->

DATA RESTRAINT

 

 

 

 

 

 

 

15

-------------

>

TRANSMIT CLOCK

15

<-------------

TRANSMIT

 

 

 

or V.54 Loop 3 *

 

 

CLOCK

 

 

 

 

 

 

 

16

-------------

>

STANDBY

16

<-------------

STANDBY

 

 

 

INDICATOR

 

 

INDICATOR

 

 

 

 

 

 

 

17

-------------

>

RECEIVE CLOCK

17

<-------------

RECEIVE CLOCK

 

 

 

 

 

 

 

18

<-------------

EXTERNAL

18

------------->

EXTERNAL

 

 

 

RECEIVE CLOCK

 

 

RECEIVE CLOCK

 

 

 

 

 

 

or V.54 Loop 3 *

 

 

 

 

 

 

 

20

<-------------

DTR

20

------------->

DTR

 

 

 

 

 

 

 

21

-------------

>

V.54 Loop 2

21

------------->

V.54 Loop 2

 

 

 

 

 

 

 

22

<-----------

>

RI/TM *

22

NC

(No Connection)

 

 

 

 

 

 

 

24

<------------

EXTERNAL TRANS-

24

------------->

EXTERNAL

 

 

 

MIT CLOCK

 

 

TRANSMIT

 

 

 

 

 

 

CLOCK

 

 

 

 

 

 

 

25

<-------------

TEST MODE

25

<-------------

MAKE BUSY

 

 

 

 

 

 

* Pin assigned double function as follows:

 

 

 

Pin 15: Outputs TRANSMIT CLOCK if the port is configured for internal clocks. Otherwise it acts as a V.54 Loop 3 signal when connected to a modem.

Pin 22: Used as the Ring Indicator output if the port is configured to emulate a dial modem. For this to work properly, the RI/TM switch of the port must be set to RI. When the RI/TM switch is set to TM, this pin acts as an input, and the TM output from the attached modem (pin 25 on the modem) comes into the 6500 on this pin.

A-2

Cables

Image 92
Contents Vanguard Managed Solutions Restricted Rights Notification for U.S. Government Users Restricted Rights LegendProprietary Material Radio Frequency Interference RegulationsPage Contents Contents This Chapter Describes About This ManualOverview Mise en garde LevelChapter Protocols Software FeaturesFeatures Hardware Card TypesProcessor Cards Support CardsEnclosure Enclosures and BackplanesStandalone Supports Other VanguardMSProducts Types of Modulus6500PLUS Processor Cards Configurations 6525PLUS NetworkConcentrator PortPlus Processor Card Front Panel Hardware 6500PLUS Auxiliary Processor Cards 6500PLUS Asynchronous and Universal I/O Cards AIO CardUIO Card Card Type Works with Port Types Split SpeedPlus Universal I/O or Asynchronous I/O Card Front Panel 6500PLUS Network Storage Option Card NSO CardPlus Network Storage Option Card 6500PLUS Token Ring Interface Module Option Token Ring Interface Module Trim CardHardware 6500PLUS Integral DSU HardwareComponents DSU InterfacePage Installation Overview ChapterInstalling Standalone Units UnpackingSite Preparation ExampleInstallation ProcedureStep Action Description/Result Rear ViewReplacing Processor Cards in Standalone Enclosures Step ActionRemove the Standalone Enclosure Door Bottom of Standalone Enclosure Using Screwdriver on Locking Tabs Locking TabsReplacement Card Plus Processor Card with Retaining ScrewStep Action Information Installing Nodes in Modulus EnclosuresAdditional Multiprocessor Nodes MultiprocessorNode Example OperationReplacing Master Processor of Multi-Processor Node Action Result/DescriptionInstalling Nodes in Modulus Enclosures Step Action Result/Description When To Add Another Processor with Flash Before You BeginAdding a Secondary 6500PLUS Processor with Flash Select Enable Flash MaintainingCurrent Software RevisionUpgrading with Software From the New Processor Card Select Copy Software to FlashInstalling/Replacing Processor Cards Modulus 8/18Requirements for Installing a Trim Card Product Description CodeTrim Card Rear Filler Panel for Modulus 8/18 Enclosures Guidelines for Installing a Trim Card in a Modulus 8/18 Trim Card Spacing in a Modulus 18 Enclosure 10. Trim Card Rear Filler Panel for Modulus 9/21 Enclosures Installing Nodes in Modulus Enclosures 11. Trim Card In Left-most Position of Modulus 21 Enclosure Plus Between Two BackplanesEnclosure Installing Nodes in Modulus Enclosures Installing and Connecting a Trim Card Attaching a Trim CardInstalling Connecting a Trim CardAttaching CablesRemoving/Replacing Trim Cards Before RemovingTrim Cards TRIM/Processor CardPreparing Modulus Enclosures for RFI Suppression Modulus 18 withInstalling RFI SuppressionScreen Modulus 18 RFINo Trim Card 15. RFI Suppression Straps Modulus 18 No Trim CardBar Modulus 21RFI Suppression Ctp CR Starting Up the NodeNode Startup Replacing Processor Card Components Processor CardReplacing DIMs Removal New DIM19. Jumpers on the Port Interface Pins Jumpers20. Installing Jumpers on the Port Interface Pins Installing SIMMs Guidelines21. Simm Installation Replacing Flash Modules 22. Flash Module Installation Replacing ID Modules ModuleReplacing Prom Chips ChipsReplacing the Cmem Chip DSU DIM Installation Installing the DSUControl Terminal Configuring the 6500PLUS for DSU Operation Output Signals DSU Input and Output SignalingInput Signals 24. Diagnostics Menu Loopback OptionsTroubleshooting DSU DIM Installation TroubleshootingFacility Interface DSU DIM FCC InformationType of Interface DSU DIM Installation Power-Up Verification CheckingLights Event Result/DescriptionPower-Up DiagnosticsSetting Node to Default Configuration NodeInstalling Software Options Accessing Node Serial Number from Node Statistics Access SerialNumber Status/Statistics Select Node Stat25. Serial Number on Node Stat Screen Enabling a Software Access Key Configure Select Software Key TableFollow These StepsInstalling New Software Options in an Existing Network Install NewEnhanced LAN Option Appendix a CablesFunction/Signal Pin Function/SignalPin Name PositionPosition Signal Name 35/V.36 Modulus 9/21 EnclosuresFunction Pin FunctionSignals Modulus 9/21 Enclosures 35/V.36 Signals Standalone and Modulus 8/18 Enclosures Signals Standalone and Modulus 8/18 Enclosures Position NamePin Function Page Unit Dimensions SpecificationsPhysical Characteristics Limits Power RequirementsEnvironmental Index DIMLL 2-69RS