SPECIFICATIONS

General

 

 

 

 

 

 

 

 

 

 

 

Power Source:

12 V DC, 800 mA

Ambient Operating Temperature:

–10°C - +50°C (14°F - 122°F)

Ambient Operating Humidity:

Less than 90 %

Dimensions:

210 mm (W) x 44 mm (H) x 350 mm (D)

 

8-1/4” (W) x 1-3/4” (H) x 13-3/4” (D)

Weight:

2.3 kg (5.1 lbs.)

Input and Output

 

 

 

 

 

 

 

 

 

 

 

Video Input:

1.0 V[p-p]/75 , NTSC Composite Video Signal (x4)

Video Output:

1.0 V[p-p]/75 NTSC Composite Video Signal (x4)

Serial Control Port:

RS-232C (9-pin D-sub Connector), RS-485 (Terminal board)

Parallel Control Port:

Default 8-bit input (I/O selectable for all bits depending on the configuration)

Image Resolution:

Selectable from 640 (H) x 480 (V); 640 (H) x 240 (V); 320 (H) x 240 (V); or 160 (H) x 120 (V)

Image Compression:

JPEG (image quality selectable in 4 stages)

Installed protocol:

HTTP, TCP/IP, PPP, FTP, SMTP

Camera Coaxial Control:

Pan/tilt, Zoom, Focus, Preset, Auto Focus (for Combination Camera WV-CS654/CS854

 

Series)

LAN Interface:

10Base-T, 8-conductor Modular Jack

Security measures:

Password type

AC Adapter

 

 

 

 

 

 

 

 

 

 

 

Input:

120 AC 60 Hz 17 W

Output:

12 V DC 800 mA

 

 

 

 

 

 

 

 

 

 

Weight and dimensions shown are approximate.

Specifications are subject to change without notice.

STANDARD ACCESSORIES

 

AC Adapter

1

Utility Software (CD-ROM)

1

Cord Clamp

1

83

Image 83
Contents Operating Instructions Lightning flash with arrowhead sym Contents Preface FeaturesHandle the appliance with care PrecautionsRear View Front View2Alarm input/output port Alarm Mode selector ModeSwitch Positions 1RS-485 setup switches RS485 SetupMounting two WJ-NT104 with the WV-Q204/2 InstallationsMounting in a Rack Mounting one WJ-NT104 with the WV-Q204/1Mounting two WJ-NT104s Rack mounting screws LAN Type Connection Access from a PC on the same subnetAccess from PCs via routers System ConnectionsDirect connection to the WJ-NT104 Access from a Client PC to the WJ-NT104Access from the WJ-NT104 to a Client PC PPP Point to Point Protocol Type ConnectionConnection to a Client PC via Hub PreparationsDirect Connection to a PC without Hub PC Setup Page IP Address Setting via RS-232C Connection WJ-NT104 SetupIP Address Setting via LAN Connection Baud RATE, Data BIT, Stop BIT, PARITY, USE Flow Control PPP Type Connection 1 P to P AccessSetup Procedures RS-232C SetupPage Dial-Up Networking Access ProceduresConnection Setup TCP/IP protocolPage Check TCP/IP in the Allowed network protocols field Access Procedures Windows NT Setup PPP Type Connection 2 Network AccessPage Windows98 Setup Main Page and Control Windows Main page and ControlsOperation Modes Random Input Selection ModeMulti Input Selection Mode ¡Multi Input Selection Mode ¡Fixed Input Selection ModeSequence Mode Fixed Input Selection ModePush Mode Pull Mode and Push ModePull Mode Image Quality Picture Quality SetupImage Resolution Live image display Main page without Camera Control index1.htmlInput Select Return to Main Quad Screen Mode index4.htmlQuad Screen Mode Alarm ListZoom Preset SelectMain page with Camera Control index2.html Pan/TiltAutopan 0PRESETIris T y u U i o !0 Preset0AUTOPAN 1PRESETAlarm List Window Alarm FunctionContinuous Recording before/after alarm mode Alarm RecordingSingle Frame Recording mode Continuous Recording after alarm modePanasonic Original Protocol Notice option Alarm NoticeAlarm Image Readout Mail Notice0CAMERA Menu Setup ProceduresHow to Read Administrator Setup T y u i o !0Multi Input Selection Mode Mode SetupRandom Input Selection Mode 2CAMERA Control Select 0FRAME Speed Control for Push Mode0 !1 1OUTPUT Data Rate ControlI o !0 Network SetupR t Alarm Setup6SERVER Address 5ALARM Notice Smtp E-MAIL1CAMERA Preset 7SENDER Name 3ALARM ContactE r t y O !0 !1 Serial Port Setup3DUPLEX Mode Modem Setup User Setup Host Setup E r FTP Client Setup1TARGET Directory Alarm Setup2ALARM Image File Name Setup 0FTP ON/OFFTime Date & Time SetupDate 0CAMERA Select Camera Menu SetupT y Connection Network SetupUtility Software Confirmation of the set values Operation Camera Menu SetupAccess Level Access AuthorizationControl of Access Authorization WJ-NT104 Authorized Functions Host Setup WindowUser Setup Window RegistrationWJ-FS616 Video Multiplexer Control SetupFixed Input Selection Mode Extension Functions2AUTO PAN 0FOCUS1IRIS Connections WJ-SX550A/B/C Matrix Switcher ControlRandom Input Selection Mode Multi Input Selection Mode1 !2 !3 PasswordVIDEO-INPUT Number and MONITOR-OUT CHAN- NEL Setup 3AUTO PAN 0ZOOM1FOCUS 2IRISWJ-DR200 AV Disk Recorder Control Selection ModeIndex Setup Control OperationAlarm REC Standby Tyu 0!5!1!6!2!7!3!84REC 0REVERSE Play1STOP 2PLAYE r 1 !2 !3 @4 @3 @2 WJ-HD100 Digital Disk Recorder Control3SEARCH 0SET1DATE 2TIMEWJ-HD500 Digital Disk Recorder Control 5!6!7 @8 @7 @6 6SET 0LEFT1ESC 4DOWNContents Upload Html Sample File mainview1.html Control by Html DescriptionImage Display CGI function for image displayHtml HEAD/HEAD Body BGCOLOR=#FFFFCC Center Camera OperationHtml Sample File nsmainview1.html CGI functions related to camera operationHtml Head Body BGCOLOR=#FFFFCC Center Titele Logo Image Html Sample File mainpanel1.htmlFont Body Html Quad ScreenScript Center Html Body BGCOLOR=#FFFFCC Center Html Sample File 2 camctrl.htmlHtml Sample File almctrl.html Alarm OperationCGI functions related to alarm Cgi-bin/chconv Substitute Character Strings in Http ServerOrdinary Html file get Cgi-bin/almctrl Ping IP address set in the WJ-NT104 TroubleshootingCctv Camera option PeripheralsNetwork System Monitoring BrowserHTTP, TCP/IP, PPP, FTP, Smtp SpecificationsGeneral Input and OutputPanasonic Canada Inc