Panasonic WJ-NT104 operating instructions Utility Software, Network Setup, Connection

Page 54

UTILITY SOFTWARE

Network Setup

For the network setup, you need to set the IP address using the Utility Software provided and connect the WJ- NT104 to a PC via the RS-232C port.

Connection

The COM1 port of the RS-232C interface is used for setting the IP address. Your PC should be IBM-PC compatible, have Windows95, Windows98 or Windows NT4.0 installed, and have an RS-232C port.

Before installing the Utility Software provided, read the Readme.txt file on Utility Software disc.

qConnect the RS-232C port on the front of the WJ-NT104 and the RS-232C port of the PC with an RS-232C cable.

wSet bits #7 and #9 of the MODE selector to ON position (leave the others on OFF), and then press the RESET button on the front of the WJ-NT104.

eClick the Start button, point to Programs and then WJ- NT104 Utilities, then click Network Configuration.

rTo set the IP address: Enter the IP address into the [IP ADDRESS] fields of the dialog box, then click the [SET] button. If the IP address has been set properly, the response command REI and the IP address enter- ed (in hexadecimal, 8-bit notation, e.g., REI:COA8000A for IP address 192.168.0.10) should appear in the WJ- NT104 RESPONSE field. If a wrong number is shown, click the [SET] button again.

tTo set the netmask: Enter a set value into the [NET- MASK] fields of the dialog box, then click the [SET] button. If the netmask has been set properly, the response command REM and the set value entered (in hexadecimal, 8-bit notation, e.g., REM:FFFFFF00 for the set value 255.255.255.0) should appear in the WJ- NT104 RESPONSE field. If a wrong number is shown, click the [SET] button again.

yTo set the default gateway: Enter a set value into the [DEFAULT GATEWAY] fields of the dialog box, then click the [SET] button. If the default gateway has been set properly, the response command REG and the set value entered (in hexadecimal, 8-bit notation, e.g., REG:COA80001 for the set value 192.168.0.1) should appear in the WJ-NT104 RESPONSE field. If a wrong number is shown, click the [SET] button again.

uComplete the setup by clicking the [EXIT] button.

iReturn all switches on the MODE selector to OFF posi- tion and then press the RESET button on the front of the WJ-NT104.

This completes setup and return to the normal applica- tion mode.

RS-232C cable

WJ-NT104

PC

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

Frame

Frame

 

Shield

9-pin D-sub connector

9-pin D-sub connector

(female)

(female)

54

Image 54
Contents Operating Instructions Lightning flash with arrowhead sym Contents Features PrefacePrecautions Handle the appliance with careFront View Rear View1RS-485 setup switches RS485 Setup Mode selector ModeSwitch Positions 2Alarm input/output port AlarmMounting one WJ-NT104 with the WV-Q204/1 InstallationsMounting in a Rack Mounting two WJ-NT104 with the WV-Q204/2Mounting two WJ-NT104s Rack mounting screws System Connections Access from a PC on the same subnetAccess from PCs via routers LAN Type ConnectionPPP Point to Point Protocol Type Connection Access from a Client PC to the WJ-NT104Access from the WJ-NT104 to a Client PC Direct connection to the WJ-NT104Preparations Direct Connection to a PC without HubConnection to a Client PC via Hub PC Setup Page WJ-NT104 Setup IP Address Setting via LAN ConnectionIP Address Setting via RS-232C Connection RS-232C Setup PPP Type Connection 1 P to P AccessSetup Procedures Baud RATE, Data BIT, Stop BIT, PARITY, USE Flow ControlPage TCP/IP protocol Access ProceduresConnection Setup Dial-Up NetworkingPage Check TCP/IP in the Allowed network protocols field Access Procedures PPP Type Connection 2 Network Access Windows NT SetupPage Windows98 Setup Main page and Controls Main Page and Control Windows¡Multi Input Selection Mode ¡Fixed Input Selection Mode Random Input Selection ModeMulti Input Selection Mode Operation ModesFixed Input Selection Mode Sequence ModePull Mode and Push Mode Pull ModePush Mode Picture Quality Setup Image ResolutionImage Quality Main page without Camera Control index1.html Input SelectLive image display Alarm List Quad Screen Mode index4.htmlQuad Screen Mode Return to MainPan/Tilt Preset SelectMain page with Camera Control index2.html Zoom0PRESET IrisAutopan T y u Preset U i o !01PRESET 0AUTOPANAlarm Function Alarm List WindowContinuous Recording after alarm mode Alarm RecordingSingle Frame Recording mode Continuous Recording before/after alarm modeMail Notice Alarm NoticeAlarm Image Readout Panasonic Original Protocol Notice optionT y u i o !0 Setup ProceduresHow to Read Administrator Setup 0CAMERA MenuMode Setup Random Input Selection ModeMulti Input Selection Mode 1OUTPUT Data Rate Control 0FRAME Speed Control for Push Mode0 !1 2CAMERA Control SelectNetwork Setup I o !0Alarm Setup R t3ALARM Contact 5ALARM Notice Smtp E-MAIL1CAMERA Preset 7SENDER Name 6SERVER AddressSerial Port Setup 3DUPLEX ModeE r t y O !0 !1 Modem Setup User Setup Host Setup FTP Client Setup E r0FTP ON/OFF Alarm Setup2ALARM Image File Name Setup 1TARGET DirectoryDate & Time Setup DateTime Camera Menu Setup T y0CAMERA Select Network Setup Utility SoftwareConnection Confirmation of the set values Camera Menu Setup OperationAccess Authorization Control of Access AuthorizationAccess Level Registration Host Setup WindowUser Setup Window WJ-NT104 Authorized FunctionsExtension Functions SetupFixed Input Selection Mode WJ-FS616 Video Multiplexer Control0FOCUS 1IRIS2AUTO PAN Multi Input Selection Mode WJ-SX550A/B/C Matrix Switcher ControlRandom Input Selection Mode ConnectionsPassword VIDEO-INPUT Number and MONITOR-OUT CHAN- NEL Setup1 !2 !3 2IRIS 0ZOOM1FOCUS 3AUTO PANSelection Mode WJ-DR200 AV Disk Recorder ControlTyu 0!5!1!6!2!7!3!8 Setup Control OperationAlarm REC Standby Index2PLAY 0REVERSE Play1STOP 4RECWJ-HD100 Digital Disk Recorder Control E r 1 !2 !3 @4 @3 @22TIME 0SET1DATE 3SEARCHWJ-HD500 Digital Disk Recorder Control 5!6!7 @8 @7 @6 4DOWN 0LEFT1ESC 6SETContents Upload CGI function for image display Control by Html DescriptionImage Display Html Sample File mainview1.htmlCGI functions related to camera operation Camera OperationHtml Sample File nsmainview1.html Html HEAD/HEAD Body BGCOLOR=#FFFFCC CenterHtml Sample File mainpanel1.html Html Head Body BGCOLOR=#FFFFCC Center Titele Logo ImageQuad Screen Script CenterFont Body Html Html Sample File 2 camctrl.html Html Body BGCOLOR=#FFFFCC CenterAlarm Operation CGI functions related to alarmHtml Sample File almctrl.html Substitute Character Strings in Http Server Ordinary Html file getCgi-bin/chconv Cgi-bin/almctrl Troubleshooting Ping IP address set in the WJ-NT104Monitoring Browser PeripheralsNetwork System Cctv Camera optionInput and Output SpecificationsGeneral HTTP, TCP/IP, PPP, FTP, SmtpPanasonic Canada Inc