&DOLEUDWLRQ
Note: Perform the calibration procedure when media and ribbon are first installed and each time a different type of media or ribbon is installed.
During this procedure, the printer automatically determines the media type, label length, media and ribbon sensor settings, and printing method. Media type is determined by sensing either continuous or
The results of this calibration are stored in the printer’s memory. These parameters remain in effect until the next calibration is performed. The printer configuration printout, which prints when the CANCEL Key Self Test is performed, lists these results as well as other printer parameters.
Note: If the printer is in the
1.Load media and ribbon (if used). Make sure the media sensor is properly positioned (see “Media and Ribbon Sensor Sensitivity Adjustment” on page 63).
Note: To use the black mark sensing mode, make sure you set the Bank 2 DIP switches appropriately (see page 41).
2.Turn the power switch ON. When the
3.Briefly press the MODE key three times. PAUSE and CALIBRATE lights turn ON.
4.Press UP (FEED Key) to calibrate. The printer feeds some media. The MODE lights flash ON and OFF to indicate that the settings have been saved in memory.
5.Press PAUSE to exit PAUSE mode. PAUSE light turns OFF.