44Installation
Prerequisites
Ensure the filler panel or cover from the power bay is removed. To remove the filler panel, see “Removing a power filler panel” (page 33).
Procedure steps
Step Action
1Grasp the handle of the new power supply and push the power supply firmly into the bay.
2Tighten the retaining screws until the power supply is firmly seated.
3Connect the power cord to the power supply and to an AC power outlet that is connected to a circuit with no other equipment connections.
Installing DC power modules
Install the DC power supply module in the leftmost bay to supply DC power to the chassis.
ATTENTION
The 8006 and 8010 chassis have three power supply bays that are numbered 1, 2, and 3 from left to right as viewed from the front of the chassis.
Prerequisites
•Verify that you have the following tools and materials:
—Cable
—Crimping tool for crimping the lugs onto the cable
—Heat gun to shrink the tubing around the cable (optional)
Nortel Ethernet Routing Switch 8600
Quick Start
30 May 2008