MGE UPS Systems 4.5 kVA, 6 kVA, 9 kVA, 12 kVA user manual Contents

Page 4

Contents

1.Presentation

1.1

Comet EXtreme range

6

 

4.5 and 6 kVA tower models

6

 

4.5 and 6 kVA rack models

6

 

9 and 12 kVA tower models

7

 

9 and 12 kVA rack models

7

1.2

Back

8

 

Comet EXtreme 4.5 and 6 kVA

8

 

Comet EXtreme 9 and 12 kVA

8

1.3

Options

9

 

EPO (Emergency Power Off)

9

 

Transformer for galvanic isolation or earthing arrangement change

9

 

Battery extensions for UPS backup times of 80 minutes

9

 

CLA module (Long backup time charger) for backup times of 2 to 8 hours

10

1.4

Control panel

11

2.Installation

2.1

Unpacking and checks

12

 

Comet EXtreme 4.5 and 6 kVA

12

 

Comet EXtreme 9 and 12 kVA

13

2.2

Installation of the rack version

14

2.3

Battery-module connections

15

 

Comet EXtreme 4.5 and 6 kVA

15

 

Comet EXtreme 9 and 12 kVA

15

2.4

Connection to the RS 232 communications port (optional)

16

2.5

Installation of the communications-card option

16

2.6

Connection to the connection modules

17

3.Operation

3.1

ON LINE operating mode

18

3.2

Start-up

19

3.3

Bargraph indications

19

Page 4 - 51033212EN/AC

Image 4
Contents Installation Comet EXtremeIntroduction Foreword Using this documentPictograms Contents Failure of AC input power and operation on battery power Glossary IndexPresentation Comet EXtreme range6 kVA tower models 6 kVA rack models12 kVA tower models 12 kVA rack models Comet EXtreme 4.5 and 6 kVA BackComet EXtreme 9 and 12 kVA EPO Emergency Power Off Battery extensions for UPS backup times of 80 minutesBattery extensions for 4.5 or 6 kVA Comet EXtreme OptionsBattery extensions for 9 or 12 kVA Comet EXtreme CLAAlarms Battery Load Remaining Control panelElectronic module Battery module InstallationUnpacking and checks Electronic module Installation of the rack version Rack mounting diagram with railsBattery-module connections Check that the battery circuit breaker 2 is OFFInstallation of the communications-card option Connection to the RS 232 communications port optionalAlways connect the earthing wire first Connection to the connection modulesON-LINE operating mode OperationStart-up When button 15 is pressedBargraph indications Failure of AC input power and operation on battery power Personalizable function Default setting PersonalizationFunction On / OFF conditions tabBattery tab Personalizable function Default setting OptionsOutput tab By-pass tabConnected equipment is no longer supplied with power ShutdownMaintenance TroubleshootingFrench Training Center on Montbonnot site USA Training Center on Costa Mesa siteMaintenance Replacement of the electronic module Disconnecting the connection moduleReconnecting the connection module Connected equipment is again protected by the UPSUPS recycling at the end of service life EnvironmentThis product has been designed to respect the environment PackingON-LINE mode AppendicesGlossary Manual bypassSleep mode Start on battery powerTolerance for AC-power Out of toleranceIndex UPS Driver32 51033212EN/AC