American Power Conversion MW manual Bottom Cable Entry, Preparing for bottom cable entry

Page 17

Bottom Cable Entry

Preparing for bottom cable entry

Cable entry in bottom cover of Input/Output Section

Top view

 

 

 

 

 

 

Battery

 

Battery

 

 

cable

 

cable

 

 

entry

 

entry

 

AC IN

 

AC OUT

cable entry

 

cable entry

 

 

 

 

 

M6 Bolt

1.75 in /

1.75 in /

44.45 mm

44.45 mm

 

 

2.3 in / 58 mm

Top view

BAT 1

BAT 2

Front view

M14

M14

M10

M10

M10

AC IN

AC OUT

90

L3 IN

95

L3 OUT

 

L2 IN

M10

L2 OUT

 

 

92 L1 IN

93 L1 OUT

M14

M14

M10

M10

M10

L1 IN

90

 

95

L1 OUT

 

BAT 1

BAT 2

 

Top view

 

 

AC IN

AC OUT

90

L3 IN

95

L3 OUT

 

L2 IN

 

L2 OUT

92

L1 IN

93

L1 OUT

L2 IN

L3 IN

91

92

94

93

L2 OUT

L3 OUT

IN/OUT power cable (bottom entry).

Symmetra MW 1000 kW 480 V Installation - 990-4112E

13

Image 17
Contents Installation Page Contents Specifications Symbols used in this guide SafetyEPO Installation safetySerial number UPS SectionsInverter Section Control SectionConfiguration 1 Inverter Section placed to the left ConfigurationsTotal width of UPS sections 4138 mm/163 Weight Configuration 2 Inverter Section placed to the rightExternal Bypass Static Switch Power wiring overview Typical UPS Wiring PrincipleInput/Output wiring precautions External disconnection switchesTop Cable Entry Preparing for top cable entry defaultBattery cable connections top cable entry Front view of Input/Output Section Ground and AC cable connections top cable entry Preparing for bottom cable entry Bottom Cable EntryElectrical Installation Bottom Cable Entry Battery cable connections bottom cable entry Battery BAT 1 + BAT 2 + IN/OUT power cable bottom entry Ground and AC cable connections bottom cable entry Bypass Static Switch Wiring Top cable entry Bottom cable entry Connectionplane 0P0957 Communication cable overviewLocation of optional Relay Board Relay Board OptionalCommunication cables with optional Relay Board Relay Board functions Relay Name Events that will trigger the alarm Mode CommentIN1 Page High-impedance grounding Low-Impedance/High-Impedance GroundingLow-impedance grounding Specifications Low-Impedance/High-Impedance Grounding Installation Planning Data Electrical SpecificationDC Input AC InputHeat Dissipation AC OutputAC Input External Bypass SSW 16 National Electrical Code Size Temperature Rating of Cables See Table Recommended cable, bolt, and lug sizes Torque specificationsOutput and downstream breakers minimum settings Required Breaker SettingsInput and upstream breakers minimum settings Dual Utility Installation Nema General Specifications 480990-4112E