American Power Conversion MW manual Contents

Page 3

Contents

Safety

1

IMPORTANT SAFETY INSTRUCTIONS

- SAVE THESE INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 1

Symbols used in this guide . . . . . . . . . . . . . . . . . . . . . . . . . 1

Installation safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

System Overview

3

UPS Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Serial number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Inverter Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Control Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Input/Output Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Configuration 1 (Inverter Section placed to the left) . . . . . . . . 4

Configuration 2 (Inverter Section placed to the right) . . . . . . . 5

External Bypass Static Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Serial number

6

Electrical Installation

7

Typical UPS Wiring Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Power wiring overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

External disconnection switches . . . . . . . . . . . . . . . . . . . . . 8

Input/Output wiring precautions . . . . . . . . . . . . . . . . . . . . . 8

Top Cable Entry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Preparing for top cable entry (default)

. 9

Battery cable connections (top cable entry)

10

Ground and AC cable connections (top cable entry)

12

Symmetra MW 1000 kW 480 V Installation - 990-4112E

i

Image 3
Contents Installation Page Contents Specifications Symbols used in this guide SafetyEPO Installation safetyControl Section UPS SectionsSerial number Inverter SectionConfiguration 1 Inverter Section placed to the left ConfigurationsTotal width of UPS sections 4138 mm/163 Weight Configuration 2 Inverter Section placed to the rightExternal Bypass Static Switch Power wiring overview Typical UPS Wiring PrincipleInput/Output wiring precautions External disconnection switchesTop Cable Entry Preparing for top cable entry defaultBattery cable connections top cable entry Front view of Input/Output Section Ground and AC cable connections top cable entry Preparing for bottom cable entry Bottom Cable EntryElectrical Installation Bottom Cable Entry Battery cable connections bottom cable entry Battery BAT 1 + BAT 2 + IN/OUT power cable bottom entry Ground and AC cable connections bottom cable entry Bypass Static Switch Wiring Top cable entry Bottom cable entry Connectionplane 0P0957 Communication cable overviewLocation of optional Relay Board Relay Board OptionalCommunication cables with optional Relay Board Relay Board functions Relay Name Events that will trigger the alarm Mode CommentIN1 Page Low-Impedance/High-Impedance Grounding Low-impedance groundingHigh-impedance grounding Specifications Low-Impedance/High-Impedance Grounding Installation Planning Data Electrical SpecificationDC Input AC InputAC Output AC Input External Bypass SSWHeat Dissipation 16 National Electrical Code Size Temperature Rating of Cables See Table Recommended cable, bolt, and lug sizes Torque specificationsRequired Breaker Settings Input and upstream breakers minimum settingsOutput and downstream breakers minimum settings Dual Utility Installation Nema General Specifications 480990-4112E