American Power Conversion AP9207 Steps in the order given. If Share-UPS fails this test, see

Page 34

Configuring Share-UPScontinued

Testing

To test the operation of Share-UPS, perform the following

Share-UPS

steps in the order given. If Share-UPS fails this test, see

 

“Troubleshooting: Table 12” on page 48.

1 Confirm that the UPS in on and that the battery is fully charged.

2 Verify that Share-UPS has been installed, con- nected, and configured.

3 Start the power management software on the serv- ers, with power management screens visible, if applicable.

4 Confirm that the Power and Status LEDs on Share-UPS are on, indicating normal operation.

5 Simulate a utility power failure.

6 Confirm that the On Batt LED of Share-UPS is on, indicating that Share-UPS is sending an On Bat- tery signal to the connected servers or devices. See “LEDs: Table 2” on page 8.

7 Confirm that all connected servers and devices have received the On Battery message from Share- UPS.

8 Restore utility power.

9 Confirm that all connected servers and devices have received the message that utility power has been restored.

Note: To check the shutdown mode of your config- uration, keep the utility power off long enough to allow all connected servers and devices to shut down. After all connected servers and devices have shut down, restore power and verify that they all restart.

28

Image 34
Contents Share-UPS Thank You Contents Setting Up Share-UPS Using the Share-UPS Menus Product Information Introduction Can delay shutdown of the UPS until all servers have Following list shows some of the features of ShareSupports advanced or simple signaling on its UPS and Share-UPS. See Using the Share-UPSOn next Cable supplied with your APC UPS Product Description On page 10. For Basic port specifications, see Basic port Tery and Low Battery conditions in the UPS. For furtherInformation see Simple versus smart signaling Table Pin assignments, onProduct Description If the LED Is… Then Share-UPS… Labeled… Product Description Key Concepts Simple Signaling Smart SignalingCommunication Types Key Concepts If the UPS had previously been connected using Smart signalingUPS on page 23, when it may force a Low Battery signal Low Battery condition at the UPS. Share-UPS generates aTo the configured shutdown mode see Configuring Share An On Battery signal, causing the servers to shut downKey Concepts Installing Multiple Accessories Accessory Priority Position Accessory slot with the higher numberInterface Expander Share-UPS unit and the master server, you can purchase an AP9604. For installation instructions, refer to the userIf you need additional SmartSlot capacity between APC Expansion Chassis AP9600 or Triple ChassisInstalling Share-UPS Mounting Share-UPS NetShelter Figure Mounting Share-UPS on a wall Figure If using Optional Power input see Optional Connecting Share-UPSConfiguring Share-UPS, on If daisy-chaining multiple Share-UPS unitsAn Expansion Chassis, is already using Ate cable. See Choosing simple signalingIf an accessory, such as Measure-UPS II or Share-UPS use simple signaling for moniConfiguring Share-UPS Behavior Confirmed shutdown mode Effect Shutdown delay, go to ConfigurationEvent Down delay for a time longer than Share-UPS timerSetting. Otherwise, if the power returns after Actions and select UPS On Battery from the EventIf you want to change Share-UPS settings Com If configuring multiple Share-UPS units repeatTroubleshooting on Steps in the order given. If Share-UPS fails this test, seeUsing the Share-UPS Menus Using the Management PortPassword-protected menu interface allows you to view Using a dumb terminal or a computer and terminal emulaTion software, you can access the UPS remotely. Load, battery conditions, and current UPS statusAs possible. See Share-UPS Settings Nected, after three unsuccessful passwordFor security, change the password as soon Characters long, and is case-sensitiveMain Menu Main menu The following figure shows the Main menu. FigureMain menu only if Share-UPS has detected an APC Measure-UPS environmental monitoring accessoryUPS accessory For a description of the Measure-UPS Status screenMain menu Following table describes the items that appear onDescription Behavior UPS Status Display Connected UPS, output and load readings, battery informaAccess the UPS Status display, type s from the Main menu Following figure shows the UPS Status displayUPS Status Display Definitions Waiting to Power Load Status display, type c from the Main menu Tions on demand through Share-UPS. To access the UPSUPS Control Menu Following figure shows the UPS Control menuUPS Control menu It is connected to the UPSFollowing figure shows the Share-UPS Settings menu Share-UPS Settings MenuShare-UPS Settings menu allows you to configure Menu, type d from the Main menuShare-UPS Settings menu Definitions Paging Setup Menu Site IDspaceevent codeFollowing figure shows a typical sequence of events During a utility power outage when Share-UPS is configUred for paging That you may include in your dial string see Share-UPS Following figure shows the Paging Setup menuFollowing table lists some common modem commands Information, see the documentation supplied withPaging Setup menu Setting DescriptionPaging Setup Menu Definitions Warranty Information Exclusion of implied warranties therefore, the aforesaid Claims by third parties, or otherwise. This warranty givesPurpose. Some jurisdictions do not permit limitation or Specifically, APC is not liable for any costs, such as lostTroubleshooting Trouble Shooting Trouble Shooting Table Persists, follow this procedure For problems not covered in the troubleshooting chart seeTroubleshooting on page 26, or if the problem Material authorization RMA numberLife-Support Policy Specifications Assignments Specifications Normally Open Data bits with 1 start bit, 1 stop bit, and no parity Communications port. The port is configured as data termiManagement port is a standard 9-pin RS-232 serial Management port pin assignments are listed in the folSpecification Following table shows the product specifications forShare-UPS Product Specifications Symbols IndexIndex Re-Boot All Servers Y, Z Page W. a p c c . c o m