American Power Conversion AP9207 manual W. a p c c . c o m

Page 72

w w w. a p c c . c o m

Toll free technical support:

U. S. & Canada

1-800-800-4272

Austria

0660 6480

Belgium

0800 15063

Czech Republic

0 800 102063

Denmark

800 18 153

Finland

9800 13 374

France

0 800 906 483

Germany

01300818907

Holland

0800 0224655

Hungary

00800 12221

Ireland

1 800 702000 x 2045

Israel

177 353 2206

Italy

1678 74731

Japan

0120-80-60-90

Luxembourg

0800 2091

Norway

800 11 632

Poland

00800 353 1202

Portugal

050 553182

South Africa

0800 994206

Spain

900 95 35 33

Sweden

020 795 419

Switzerland

0800 556177

Turkey

0800 35390275

U. K.

0800 132990

Areas without toll free numbers:

+1 401 789 5735 (USA) or

+353 91 702020 (Ireland)

+7095 916 7166 (Russia)

E-mail technical support:

Australia

anztech@apcc.com

Europe

apceurtech@apcc.com

India

isbtech@apcc.com

Japan

jsupport@apcc.com

Latin America

apctchla@apcc.com

SE Asia

asetech@apcc.com

Online Technical Support

U.S. & Canada http://support.apcc.com/

Addresses:

American Power Conversion Corporation

132 Fairgrounds Road

P. O. Box 278

West Kingston, Rhode Island 02892

USA

APC Ireland (A. P. C.) b. v. Ballybritt Business Park Galway

Ireland

APC Japan

BR Gotanda 7th Floor

2-30-4 Nishi-gotanda,

Shinagawa-ku

Tokyo 141 Japan

APC Europe

143 Bis Avenue de Verdun

92442 Issy les Moulineaux Cedex France

Serial number:

Entire contents copyright © 1999 American Power Conversion. All rights reserved.

Reproduction in whole or in part without permission is prohibited. All trademarks are the property of American Power Conversion.

990-0097B3/99

Image 72
Contents Share-UPS Thank You Contents Setting Up Share-UPS Using the Share-UPS Menus Product Information Introduction Following list shows some of the features of Share Supports advanced or simple signaling on itsCan delay shutdown of the UPS until all servers have UPS and Share-UPS. See Using the Share-UPSOn next Cable supplied with your APC UPS Product Description Tery and Low Battery conditions in the UPS. For further Information see Simple versus smart signaling TableOn page 10. For Basic port specifications, see Basic port Pin assignments, onProduct Description If the LED Is… Then Share-UPS… Labeled… Product Description Simple Signaling Smart Signaling Key ConceptsCommunication Types Key Concepts If the UPS had previously been connected using Smart signalingLow Battery condition at the UPS. Share-UPS generates a To the configured shutdown mode see Configuring ShareUPS on page 23, when it may force a Low Battery signal An On Battery signal, causing the servers to shut downKey Concepts Installing Multiple Accessories Accessory slot with the higher number Accessory Priority PositionInterface Expander AP9604. For installation instructions, refer to the user If you need additional SmartSlot capacity betweenShare-UPS unit and the master server, you can purchase an APC Expansion Chassis AP9600 or Triple ChassisInstalling Share-UPS Mounting Share-UPS NetShelter Figure Mounting Share-UPS on a wall Figure Connecting Share-UPS Configuring Share-UPS, onIf using Optional Power input see Optional If daisy-chaining multiple Share-UPS unitsAte cable. See Choosing simple signaling If an accessory, such as Measure-UPS II orAn Expansion Chassis, is already using Share-UPS use simple signaling for moniConfiguring Share-UPS Behavior Confirmed shutdown mode Effect Down delay for a time longer than Share-UPS timer Setting. Otherwise, if the power returns afterShutdown delay, go to ConfigurationEvent Actions and select UPS On Battery from the EventIf you want to change Share-UPS settings Com If configuring multiple Share-UPS units repeatTroubleshooting on Steps in the order given. If Share-UPS fails this test, seeUsing the Share-UPS Menus Using the Management PortUsing a dumb terminal or a computer and terminal emula Tion software, you can access the UPS remotely.Password-protected menu interface allows you to view Load, battery conditions, and current UPS statusNected, after three unsuccessful password For security, change the password as soonAs possible. See Share-UPS Settings Characters long, and is case-sensitiveMain Menu Main menu The following figure shows the Main menu. FigureMeasure-UPS environmental monitoring accessory UPS accessoryMain menu only if Share-UPS has detected an APC For a description of the Measure-UPS Status screenFollowing table describes the items that appear on Main menuDescription Behavior Connected UPS, output and load readings, battery informa Access the UPS Status display, type s from the Main menuUPS Status Display Following figure shows the UPS Status displayUPS Status Display Definitions Waiting to Power Load Tions on demand through Share-UPS. To access the UPS UPS Control MenuStatus display, type c from the Main menu Following figure shows the UPS Control menuUPS Control menu It is connected to the UPSShare-UPS Settings Menu Share-UPS Settings menu allows you to configureFollowing figure shows the Share-UPS Settings menu Menu, type d from the Main menuShare-UPS Settings menu Definitions Paging Setup Menu Site IDspaceevent codeDuring a utility power outage when Share-UPS is config Following figure shows a typical sequence of eventsUred for paging Following figure shows the Paging Setup menu Following table lists some common modem commandsThat you may include in your dial string see Share-UPS Information, see the documentation supplied withPaging Setup menu Setting DescriptionPaging Setup Menu Definitions Warranty Information Claims by third parties, or otherwise. This warranty gives Purpose. Some jurisdictions do not permit limitation orExclusion of implied warranties therefore, the aforesaid Specifically, APC is not liable for any costs, such as lostTroubleshooting Trouble Shooting Trouble Shooting Table For problems not covered in the troubleshooting chart see Troubleshooting on page 26, or if the problemPersists, follow this procedure Material authorization RMA numberLife-Support Policy Specifications Assignments Specifications Normally Open Communications port. The port is configured as data termi Management port is a standard 9-pin RS-232 serialData bits with 1 start bit, 1 stop bit, and no parity Management port pin assignments are listed in the folFollowing table shows the product specifications for SpecificationShare-UPS Product Specifications Symbols IndexIndex Re-Boot All Servers Y, Z Page W. a p c c . c o m