9.0 Specifications

9.1 Input

UPS version (Vac):

100

120

220/230/240

Nominal input voltage (Vac): single phase

 

100

 

120

230

 

 

 

 

 

 

 

Nominal input frequency:

 

 

 

50 or 60 Hz.

 

Internally selected by microprocessor.

 

 

 

 

 

 

 

 

 

 

 

 

Input protection:

 

 

7 Amp

 

7 Amp

5 Amp

Push-to-reset circuit breaker.

 

 

 

 

 

 

Input connections: IEC 320 male inlet coupler. 120 and 100 Vac versions

include 6 ft (2 m) line cord, with a NEMA 5-15P three pronged plug.

 

 

 

 

 

 

 

9.2 Transfer characteristics

 

 

 

 

 

 

 

 

 

Frequency limits for on-line operation:

 

50 or 60 Hz, ±5%

 

 

 

 

 

 

Lower input voltage, on-line operation:

 

80 Vac

 

90 Vac

173 Vac

Upper input voltage, on-line operation:

 

110 Vac

 

132 Vac

253 Vac

SmartBoost operation line voltage(Vac):

 

80–90

 

90–103

173–196

Transfer time:

 

 

 

2 ms typical;

(1 ms is 0.001 seconds).

 

 

4 ms maximum.

 

 

 

 

 

 

 

Note that these are the default values. Transfer parameters may be configured using UPS monitoring software.

9.3 Output characteristics

On-battery output voltage (Vac):

100 ±5%

115 ±5%

225 ±5%

 

 

 

 

Maximum output current:

4.0 Amp

3.5 Amp

1.8 Amp

Maximum load:

 

400 VA or

 

250 W at 0.63 power factor

On-battery Frequency:

50 or 60 Hz, ±0.1 Hz.

Synchronized to mains frequency during brownout.

 

 

 

 

 

 

On-battery waveshape:

 

sinewave.

 

Protection: Overcurrent and short-circuit protected, latching shutdown upon overload.

Output connections: 100 and 120 Vac versions have four NEMA 5-15R receptacles. 220/230/240 Vac version has four IEC 320 output couplers and includes two 6 ft (2 m) output cords with IEC 320 couplers and one IEC rewireable plug adapter.

37

Image 39
Contents Smart-UPS Radio frequency interference Important safety instructionsTable of Contents Storing the UPS SpecificationsOverview IntroductionExtended capabilities Battery replacement indicators and testSmartBoost Remote interfacesEnglish SafetyFrançais SécuritéVorsicht Sicherheit¡Atencion ¡SeguridadPresentation 400VA UPS-front panel400VA UPS-rear panel Installation PlacementReceiving inspection 220/230/240 Vac version 100, 120 Vac versionsAuto-on operation Charge the batteriesPlug in the master device Plug in the accessory devicesConfigure Option Switch 4 and UPS Enable switch Turn on accessoriesEnable the UPS Manual operationPlug loads into UPS Operation Test button functions 5.2.1 Line Voltage bar graph UPS self-test Output Power bar graphReplace battery Audible alarmsOn-battery alarm Low batteryOption Switch Option switchesVac version No function not used Monitoring Status reportingPower management Operation customizing Turn on delay Audible alarm operationMinimum battery capacity to restart Shut down, turn off delayPowerChute Software UPS MonitoringInterface Kits Computer Interface port Difficulty Difficulté Schwierigkeit Dificultad Troubleshooting SolutionPossible cause Troubleshooting UPS Battery replacement check Obtaining service Storing the UPS Storage conditionsExtended storage Input SpecificationsTransfer characteristics Output characteristicsBattery and charger UPS version Vac Surge and noise suppressionOperating Environment Size H´W´D WeightPhysical ApprovalsLoad Run Time Typical computer VA † minutes ‡ Equivalents Typical run times versus loadLife support policy Limited Warranty∗ Mailing