APC 600 Battery and charger UPS version Vac, Surge and noise suppression, Operating Environment

Page 39

9.0 Specifications

9.4 Battery and charger UPS version (Vac): 100

120

220/230/240

Battery type: Spill proof, maintenance free sealed lead-calcium.

Typical battery life:3 to 6 years.

Battery life dependent on number of discharges and ambient temperature.

Low battery signaling: Continuous visual and audible alarm 2 minutes before shutdown.

Recharge time: 4 to 10 hours typical from total discharge. UPS may be used immediately after discharge but will provide shorter backup time.

9.5 Surge and noise suppression

Surge energy rating (Joules, maximum):

160

320

320

One occurrence, 10/1000 µs waveform.

 

 

 

Surge current capability (maximum):

6500 Amp peak.

One occurrence, 8/20 µs waveform.

 

 

 

Surge response time: 0 ns (instantaneous) normal mode; less than 5 ns

common mode.

 

 

 

 

 

 

 

Surge voltage let-through:

<0.7%

<0.7%

<2.0%

per ANSI C62.41 Cat. A 6 kV test.

 

 

 

 

 

 

 

Noise filter range:

100 kHz to 10 MHz

Normal and common mode EMI/RFI suppression.

 

 

9.6 Operating Environment

Temperature:

0 to +40°C (+32 to +104°F)

 

 

Relative humidity:

0 to 95%, non-condensing

 

 

Operating & storage relative humidity:

0 to 95%, non-condensing

 

 

Operating elevation:

0 to 3,000 m (0 to 10,000 ft)

 

 

Storage elevation:

0 to 15,000 m (0 to 50,000 ft)

Electromagnetic immunity:

IEC 801-2 level IV, 801-3 level III, 801-4 level IV, 801-5 level III.

Audible noise:

<45 dBA at 1 m (3 ft)

37

Image 39
Contents Smart-UPS Radio frequency interference Important safety instructionsTable of Contents Storing the UPS SpecificationsOverview IntroductionExtended capabilities Battery replacement indicators and testSmartBoost Remote interfacesEnglish SafetyFrançais SécuritéVorsicht Sicherheit¡Atencion ¡Seguridad600VA UPS-100 and 120 Vac versions Presentation600VA UPS-220/230/240 Vac version Installation PlacementReceiving inspection 220/230/240 Vac version 100, 120 Vac versionsPlug loads into UPS Enable UPSSwitch on the UPS Switch on load equipmentOperation Test button Power on buttonPower standby button Alarm disable buttonLine Voltage bar graph Output Power bar graphReplace battery Audible alarmsOn-battery alarm Low batteryOption Switch Option switchesVac version No function not used Monitoring Status reportingPower management Operation customizing Turn on delay Audible alarm operationMinimum battery capacity to restart Shut down, turn off delayPowerChute Software UPS MonitoringInterface Kits Computer interface port Difficulty Difficulté Schwierigkeit Dificultad Troubleshooting SolutionPossible cause Troubleshooting Battery replacement check Obtaining service Storing the UPS Storage conditionsExtended storage Input SpecificationsTransfer characteristics Output characteristicsBattery and charger UPS version Vac Surge and noise suppressionOperating Environment Size H´W´D WeightPhysical ApprovalsLoad Run Time Typical computer VA † Minutes ‡ Equivalents Typical run times versus loadPage Life support policy Limited Warranty∗ Mailing