APC 600 user manual Safety, English

Page 7

2.0 Safety!

ENGLISH

Caution!

CAUTION!

To reduce the risk of electric shock, disconnect the Uninterruptible Power Source from the mains before installing computer interface signal cable (when used). Reconnect the power cord only after all signalling interconnections have been made.

Connect the Uninterruptible Power Source to a two-pole, three-wire grounding mains receptacle. The receptacle must be connected to appropriate branch protection (fuse or circuit breaker). Connection to any other type of receptacle may result in a shock hazard and may violate local electrical codes.

This Uninterruptible Power Source has an internal energy source

(the battery) that cannot be de-energized by the user. The output may be energized when the unit is not connected to a mains supply.

To properly deenergize the Uninterruptible Power Source in an emergency, move the rear panel I/O switch to the O (off) position and disconnect the power cord from the mains.

Avoid installing the Uninterruptible Power Source in locations where there is water or excessive humidity.

Do not allow water or any foreign object to get inside the Uninterruptible Power Source. Do not put objects containing liquid on or near the unit.

To reduce the risk of overheating the Uninterruptible Power Source, avoid exposing the unit to the direct rays of the sun. Avoid installing the unit near heat emitting appliances such as a room heater or stove.

5

Image 7
Contents Smart-UPS Radio frequency interference Important safety instructionsTable of Contents Storing the UPS SpecificationsOverview IntroductionExtended capabilities Battery replacement indicators and testSmartBoost Remote interfacesEnglish SafetyFrançais SécuritéVorsicht Sicherheit¡Atencion ¡Seguridad600VA UPS-100 and 120 Vac versions Presentation600VA UPS-220/230/240 Vac version Placement InstallationReceiving inspection 220/230/240 Vac version 100, 120 Vac versionsPlug loads into UPS Enable UPSSwitch on the UPS Switch on load equipmentOperation Test button Power on buttonPower standby button Alarm disable buttonLine Voltage bar graph Output Power bar graphReplace battery Audible alarmsOn-battery alarm Low batteryOption Switch Option switchesVac version No function not used Monitoring Status reportingPower management Operation customizing Turn on delay Audible alarm operationMinimum battery capacity to restart Shut down, turn off delayUPS Monitoring PowerChute SoftwareInterface Kits Computer interface port Difficulty Difficulté Schwierigkeit Dificultad Solution TroubleshootingPossible cause Troubleshooting Battery replacement check Obtaining service Storage conditions Storing the UPSExtended storage Input SpecificationsTransfer characteristics Output characteristicsSurge and noise suppression Battery and charger UPS version VacOperating Environment Size H´W´D WeightPhysical ApprovalsLoad Run Time Typical computer VA † Minutes ‡ Equivalents Typical run times versus loadPage Life support policy Limited Warranty∗ Mailing