American Dynamics ADMPCPU manual Using an IP Address Assigned by the Network Dhcp Server, ADCC1100

Page 12

4.Switch on the CPU. The LCD screen displays the AD Welcome Screen (Figure 10), followed by the CPU Status screen, two examples of which are shown in Figure 11.

Figure 10. AD welcome screen

Figure 11. CPU status screen

or

ADCC1100:

a.Place the keyboard in Program Mode by clicking the tab in the middle of the lower part of the screen).

Note: To display and enter Program Mode, you must insert a Smartcard that has administrator privileges.

b.Press the Matrix Menus softkey.

c.Enter one of the following number sequences for your MegaPower CPU installation:

Standalone MPCPU: Enter 100.

Dual MPCPU: Enter 100 for the selected MegaPower CPU, or enter 101 for the Standby MP CPU.

d.Press the Enter softkey.

ADCC0200/0300:

Using an IP Address Assigned by the Network DHCP Server

To set up the MegaPower CPU to obtain an IP address from a DHCP server, do the following:

1.Connect a keyboard to an RS-232 port on the MegaPower CPU. Ensure the baud rates match for the keyboard and CPU port in use.

2.Use the following instructions to provide the key sequences for each supported keyboard:

AD2088:

a.Place the keyboard in Menu Mode by turning the keyswitch to MENU. The Camera field LED on the keyboard should display P6.

b.Enter one of the following number sequences for your MegaPower CPU installation:

Standalone MPCPU: Enter 100.

Dual MPCPU: Enter 100 for the selected MegaPower CPU, or enter 101 for the Standby MP CPU.

c.Press the ENTER key, which is located above the joystick. “ENTER” is stenciled on the front face of the key; the top of the key may be labeled either PRESET or SHOT.

The Camera field LED on the keyboard will only display 7P if the selected CPU is accessed.

Notes: In RS–232 mode, the ADCC0200 keyboard does not have matrix menu access capabilities as indicated by the Access Denied message if the following procedure is attempted.

a.Press and hold the Shift () button and then press the Menu () button.

b.Enter one of the following number sequences for your MegaPower CPU installation:

Standalone MPCPU: Enter 100.

Dual MPCPU: Enter 100 for the selected MegaPower CPU, or enter 101 for the Standby MP CPU.

c.Press Enter ().

Note: Whenever scrolling to a different line

item on the LCD screen, you must press twice to select the new item.

Note: To exit Program Mode, press and hold the Shift () button, and then press the Clear () button.

ADTTE:

a.Place the keyboard in Program Mode (indicated by –Pbeing displayed at the far right of the LCD).

b.Press the Menu key. The LCD screen displays P6 - M.

c.Enter one of the following number sequences for your MegaPower CPU installation:

Standalone MPCPU: Enter 100

MEGAPOWER CPU ADMINISTRATOR’S GUIDE

8200-0421-03, REV. G

10 of 82

Image 12
Contents MegaPower CPU Page MegaPower CPU About the ProductAbout this Guide Contents Removing Monitors or Satellite Sites Access From Keyboards MegaPower 3200 Video-Matrix Cctv System Dual CPU MegaPower CPU Front PanelMegaPower System Overview CPU Rear PanelSystem Components System CapabilitiesSystem Features Compatible System KeyboardsAdministrator Tasks Operator TasksInitializing the System Understanding the Screen IconsDirect Connection RS-232 Port S3 SoftwareEthernet Network Connection Ethernet Port Easy CPU SoftwareUsing an IP Address Assigned by the Network Dhcp Server ADCC1100Standalone Mpcpu Enter ADCC0200/0300Using a Static IP Address System Menu screenFirewall Setup Read CycleInstalling Easy CPU Error Message ExampleBeginning the Installation Write CycleChoose Setup Language dialog Language, go to Appendix a End User License Agreement onLicense Agreement screen Configuring Preferences Starting Easy CPUViewing Configuration File Properties Saving Data on the Hard DriveRetrieving Configuration Data Factory-Default or Existing Configuration Data in CPUConfiguration Data File Only in PC Write to Mpcpu and/or Save Configuration To File dialog New Configuration File Adding a User Login Login Manager dialogLogging in Users for CPU Read/Write Access Login dialogProgramming the MegaPower CPU Easy CPU Main Screen OverviewDropdown Menus File Edit HelpSettings Window Display Area Checking the System StatusMonitor Status Explore MenuPassive Hot Switch Status Camera StatusError Log Status Configuring the System Setting System Options− Installing a Tftp server Setting System Date and Time Setting the Date and Time Using the Dialog BoxSetting the Date and Time Using the Keyboard System Date & Time dialogSetting Port Configurations Configuring the Dome/PTZ Device Direct ConnectionDome/PTZ Device Direct Connect Configuration screen Configuring Switching Creating SalvosSalvos Preset or Pattern Dropdown List Deleting Salvos or Alarm Contacts Creating ToursTours Section Event Timers Event Timers Alarm TablesEvent Timer Tours Scheduling System Tours with the Event TimerDeleting Tours in the Event Timer Screen Alarm TablesConfiguring Alarms Setting Up Alarm MonitorsAdding Monitor Definitions Group these monitors together Event Timers Viewing Event TimersDeleting Event Timers Contact ArmingCreating Alarm Monitor/ Contact Tables Dropdown ListEmail Message dialog Alarm Messages Defining System DevicesEmail Messages Defining CamerasAdding Camera Definitions Adding and Deleting Calling Contacts to Cameras onAdding and Deleting Calling Contacts to Cameras Editing Camera DefinitionsAssociating Salvo Callups to Cameras Deleting Calling ContactsDeleting Salvo Callups Adding Monitor Access to Keyboards Defining KeyboardsAdding Keyboard Definitions Editing and Deleting Keyboard DefinitionsAdding Site Access to Keyboards Adding a Range of MonitorsConfiguring Keyboard/User Keyboards and Priorities Removing Monitor or Site AccessUser Enable Logon checkbox settings Configuring the Keyboard/User Priority Settings Deleting Keyboard/User Priorities SettingsControlling Access with Partitions Defining Satellite SitesAssociating Cameras to Monitors Deleting Satellite SitesPartitions cameras to monitors screen Editing Camera Definitions Changing Calling ContactsAssociating Keyboards to Cameras Removing Calling ContactsEditing Keyboard Definitions Deleting Keyboard DefinitionsAdding Cameras to Keyboards Adding a Range of CamerasRemoving Monitors or Satellite Sites Access from Keyboards Associating Keyboards to MonitorsAdding Monitor Access to Keyboards Adding Monitors to KeyboardsAssociating Keyboards to Satellites Removing Monitors from KeyboardsAdding Site Access to Keyboards Associating Monitors to Cameras Adding Satellite Sites to KeyboardsRemoving Satellite Sites from Keyboards Adding Monitor Definitions Adding a Range of Cameras Adding ContactsPerforming a Ping Test Declarations Regulatory ComplianceRegulatory Type Other DeclarationsAppendix a End User License Agreement Scope of LicenseExport Restrictions Appendix B MegaPower CPU System Defaults Appendix C MegaPower CPU Front Panel LCD Menu Structure Appendix D Port Number Assignments Purpose Protocol Port DescriptionAppendix E Auxiliary Key Code Functions F1 Special Function KeysF2 Special Function Keys 55-F2 60-F261-F2 62-F2Appendix F Configuring Video Loss Detection Video Loss Detection dropdown menuMegapower CPU ADMINISTRATOR’S Guide Appendix G Alarm Programming Overview Alarm ReceiptAlarm Arming and Response Alarm Display IndicatorsAlarm Display Method Alarm Queuing MethodAlarm Clearance Method Appendix H Monitor Arming MethodsMegapower CPU ADMINISTRATOR’S Guide Appendix I Monitor Arming Codes Single Display, Sequence QueuingSingle Display, Hold Queuing Block Display, Sequence QueuingBlock Display, Hold Queuing Dual Display, Hold and Sequence QueuingAppendix J Alarm Arming Notes Appendix K Satellite Configuration Overview Setting Up Satellite SitesSatellite Site Connections Site 1 Source Site Site 1 Source and Receiving Site 2 Source and Receiving Page 8200-0421-03 G