Contact Arming

The Contact Arming screen enables you to assign a group of contacts in an alarm table to a monitor.

Figure 77. Contact Arming screen

To begin assigning a group of contacts to a monitor from the Alarms – Monitor screen:

1.Click on a monitor.

2.Click the Contact Arming tab. The selected monitor number appears just below the tab in the Monitor field.

3.Click Add on the right side of the screen. The Add Contacts dialog box appears (Figure 78 on page 39).

Figure 78. Add Contacts dialog

The Add Contacts dialog provides three options.

1.To select an option, click the button beside the option, and complete the required information. Options are:

Replace with the following sequence – enter a range of monitors, for example, 1-256.

Add a single Contact – Click the up or down arrows to select a contact.

Add a range of Contacts – Click the up or down arrows on the “from” and “to” fields to select a range of contacts.

2.Click OK to save your contact choices or Cancel to close the dialog box without saving your choices.

Deleting Contacts

To delete contacts assigned to a monitor as defined in the Contact Arming tab, do the following:

1.In the upper screen, click on the monitor that contains the contact(s) to be deleted.

2.Click on the contact(s) in the lower screen to be deleted, and then press Remove on the right side of the screen.

Event Timers

The Event Timers tab in the Alarms – Monitor screen allows you to view and delete event timer information that is associated with selected monitors.

Note: Event timers displayed in this screen are for information only, and they cannot be added or edited here. You must define event timers in the Switching – Event Timer screen as described on page 35.

Viewing Event Timers

To view event timer information from the Alarms – Monitor screen:

1.Click on a monitor in the upper screen.

2.Click the Event Timers tab on the Alarms – Monitor screen.

Figure 79. Event timers screen

Deleting Event Timers

To delete an event timer definition:

1.Click on a monitor in the upper screen.

2.Click the header of the row in the lower screen that contains the event timer definition to be deleted.

3.Press the keyboard Delete key of the PC running EASY CPU. The Delete Rows dialog box appears.

MEGAPOWER CPU ADMINISTRATOR’S GUIDE

8200-0421-03, REV. G

39 of 82

Image 41
Contents MegaPower CPU Page About this Guide MegaPower CPUAbout the Product Contents Removing Monitors or Satellite Sites Access From Keyboards MegaPower CPU Front Panel MegaPower 3200 Video-Matrix Cctv System Dual CPUCPU Rear Panel MegaPower System OverviewSystem Components System CapabilitiesCompatible System Keyboards System FeaturesOperator Tasks Administrator TasksUnderstanding the Screen Icons Initializing the SystemDirect Connection RS-232 Port S3 SoftwareEthernet Port Easy CPU Software Ethernet Network ConnectionADCC1100 Using an IP Address Assigned by the Network Dhcp ServerStandalone Mpcpu Enter ADCC0200/0300System Menu screen Using a Static IP AddressRead Cycle Firewall SetupError Message Example Installing Easy CPUBeginning the Installation Write CycleLanguage, go to Appendix a End User License Agreement on Choose Setup Language dialogLicense Agreement screen Starting Easy CPU Configuring PreferencesSaving Data on the Hard Drive Viewing Configuration File PropertiesConfiguration Data File Only in PC Retrieving Configuration DataFactory-Default or Existing Configuration Data in CPU Write to Mpcpu and/or Save Configuration To File dialog New Configuration File Login Manager dialog Adding a User LoginLogin dialog Logging in Users for CPU Read/Write AccessEasy CPU Main Screen Overview Programming the MegaPower CPUDropdown Menus File Edit HelpChecking the System Status Settings Window Display AreaMonitor Status Explore MenuCamera Status Passive Hot Switch StatusError Log Status − Installing a Tftp server Configuring the SystemSetting System Options Setting the Date and Time Using the Dialog Box Setting System Date and TimeSystem Date & Time dialog Setting the Date and Time Using the KeyboardConfiguring the Dome/PTZ Device Direct Connection Setting Port ConfigurationsDome/PTZ Device Direct Connect Configuration screen Creating Salvos Configuring SwitchingSalvos Preset or Pattern Dropdown List Tours Section Deleting Salvos or Alarm ContactsCreating Tours Event Timers Alarm Tables Event TimersScheduling System Tours with the Event Timer Event Timer ToursDeleting Tours in the Event Timer Screen Alarm TablesAdding Monitor Definitions Configuring AlarmsSetting Up Alarm Monitors Group these monitors together Viewing Event Timers Event TimersDeleting Event Timers Contact ArmingDropdown List Creating Alarm Monitor/ Contact TablesEmail Message dialog Defining System Devices Alarm MessagesEmail Messages Defining CamerasAdding and Deleting Calling Contacts to Cameras on Adding Camera DefinitionsEditing Camera Definitions Adding and Deleting Calling Contacts to CamerasDeleting Salvo Callups Associating Salvo Callups to CamerasDeleting Calling Contacts Defining Keyboards Adding Monitor Access to KeyboardsAdding Keyboard Definitions Editing and Deleting Keyboard DefinitionsAdding a Range of Monitors Adding Site Access to KeyboardsUser Enable Logon checkbox settings Configuring Keyboard/User Keyboards and PrioritiesRemoving Monitor or Site Access Deleting Keyboard/User Priorities Settings Configuring the Keyboard/User Priority SettingsDefining Satellite Sites Controlling Access with PartitionsAssociating Cameras to Monitors Deleting Satellite SitesPartitions cameras to monitors screen Changing Calling Contacts Editing Camera DefinitionsRemoving Calling Contacts Associating Keyboards to CamerasDeleting Keyboard Definitions Editing Keyboard DefinitionsAdding Cameras to Keyboards Adding a Range of CamerasAssociating Keyboards to Monitors Removing Monitors or Satellite Sites Access from KeyboardsAdding Monitors to Keyboards Adding Monitor Access to KeyboardsRemoving Monitors from Keyboards Associating Keyboards to SatellitesAdding Site Access to Keyboards Removing Satellite Sites from Keyboards Associating Monitors to CamerasAdding Satellite Sites to Keyboards Adding Monitor Definitions Adding Contacts Adding a Range of CamerasPerforming a Ping Test Regulatory Compliance DeclarationsRegulatory Type Other DeclarationsScope of License Appendix a End User License AgreementExport Restrictions Appendix B MegaPower CPU System Defaults Appendix C MegaPower CPU Front Panel LCD Menu Structure Purpose Protocol Port Description Appendix D Port Number AssignmentsF2 Special Function Keys Appendix E Auxiliary Key Code FunctionsF1 Special Function Keys 60-F2 55-F261-F2 62-F2Video Loss Detection dropdown menu Appendix F Configuring Video Loss DetectionMegapower CPU ADMINISTRATOR’S Guide Alarm Receipt Appendix G Alarm Programming OverviewAlarm Arming and Response Alarm Display IndicatorsAlarm Queuing Method Alarm Display MethodAlarm Clearance Method Appendix H Monitor Arming MethodsMegapower CPU ADMINISTRATOR’S Guide Single Display, Sequence Queuing Appendix I Monitor Arming CodesSingle Display, Hold Queuing Block Display, Sequence QueuingDual Display, Hold and Sequence Queuing Block Display, Hold QueuingAppendix J Alarm Arming Notes Setting Up Satellite Sites Appendix K Satellite Configuration OverviewSatellite Site Connections Site 1 Source Site Site 1 Source and Receiving Site 2 Source and Receiving Page 8200-0421-03 G