American Dynamics ADMPCPU manual Appendix I Monitor Arming Codes, Single Display, Sequence Queuing

Page 78

APPENDIX I: Monitor Arming Codes

Monitor Arming Codes identify the alarm display, queuing, and clearance methods for armed monitors, as well as the arm type (an abbreviated code that displays on the monitor when an alarm occurs).

The following arming codes are available.

Single Display, Sequence Queuing

SSI – Single alarm monitor, all alarms are queued and sequenced. Alarms are cleared when the alarm closures is restored (Instant).

SSI A – Single alarm monitor, all alarms are queued and sequenced. Alarms are cleared when the alarm closure is restored or when the user clears the alarm (Instant or Manual).

SSA – Single alarm monitor, all alarms are queued and sequenced. Alarms are cleared 20 seconds after the alarm closure is restored (Automatic).

SSA A – Single alarm monitor, all alarms are queued and sequenced. Alarms are cleared 20 seconds after the alarm closure is restored or when the user clears the alarm (Automatic or Manual).

SSM – Single alarm monitor, all alarms are queued and sequenced. Alarms are cleared only when the operator clears the alarm (Manual).

Single Display, Hold Queuing

SHI – Single alarm monitor, all alarms are queued, and the first alarmed contact is displayed and held until cleared. Alarms are cleared when the alarm closure is restored (Instant).

SHI A – Single alarm monitor, all alarms are queued, and the first alarmed contact is displayed and held until cleared. Alarms are removed from the queue when the alarm closure is restored or when the user clears the alarm (Instant or Manual).

SHA – Single alarm monitor, all alarms are queued, and the first alarmed contact is displayed and held until cleared. Alarms are removed from the queue 20 seconds after the alarm closure is restored (Automatic).

SHA A – Single alarm monitor, all alarms are queued, and the first alarmed contact is displayed and held until cleared. Alarms are removed from the queue 20 seconds after the alarm closure is restored or when the user clears the alarm (Automatic or Manual).

SHM – Single alarm monitor, all alarms are queued, and the first alarmed contact is displayed and held until cleared. Alarms are removed from the queue only when the operator clears the alarm (Manual).

Block Display, Sequence Queuing

BSI – Multiple monitor alarm block, all alarms are queued and displayed on monitors with no existing alarms. When all monitors have alarms, alarms sequence evenly on all monitors. Alarms are removed from the queue when the alarm closure is restored (Instant).

BSI A – Multiple monitor alarm block, all alarms are queued and displayed on monitors with no existing alarms. When all monitors have alarms, alarms sequence evenly on all monitors. Alarms are removed from the queue when the alarm closure is restored or when the user clears the alarm (Instant or Manual).

BSA – Multiple monitor alarm block, all alarms are queued and displayed on monitors with no existing alarms. When all monitors have alarms, alarms sequence evenly on all monitors. Alarms are removed from the queue 20 seconds after the alarm closure is restored (Automatic).

BSA A – Multiple monitor alarm block, all alarms are queued and displayed on monitors with no existing alarms. When all monitors have alarms, alarms sequence evenly on all monitors. Alarms are removed from the queue 20 seconds after the alarm closure is restored or when the user clears the alarm (Automatic or Manual).

BSM – Multiple monitor alarm block, all alarms are queued and displayed on monitors with no existing alarms. When all monitors have alarms, alarms sequence evenly on all monitors. Alarms are removed from the queue only when the operator clears the alarm (Manual).

MEGAPOWER CPU ADMINISTRATOR’S GUIDE

8200-0421-03, REV. G

76 of 82

Image 78
Contents MegaPower CPU Page MegaPower CPU About the ProductAbout this Guide Contents Removing Monitors or Satellite Sites Access From Keyboards MegaPower 3200 Video-Matrix Cctv System Dual CPU MegaPower CPU Front PanelSystem Components MegaPower System OverviewCPU Rear Panel System CapabilitiesSystem Features Compatible System KeyboardsAdministrator Tasks Operator TasksDirect Connection Initializing the SystemUnderstanding the Screen Icons RS-232 Port S3 SoftwareEthernet Network Connection Ethernet Port Easy CPU SoftwareStandalone Mpcpu Enter Using an IP Address Assigned by the Network Dhcp ServerADCC1100 ADCC0200/0300Using a Static IP Address System Menu screenFirewall Setup Read CycleBeginning the Installation Installing Easy CPUError Message Example Write CycleChoose Setup Language dialog Language, go to Appendix a End User License Agreement onLicense Agreement screen Configuring Preferences Starting Easy CPUViewing Configuration File Properties Saving Data on the Hard DriveRetrieving Configuration Data Factory-Default or Existing Configuration Data in CPUConfiguration Data File Only in PC Write to Mpcpu and/or Save Configuration To File dialog New Configuration File Adding a User Login Login Manager dialogLogging in Users for CPU Read/Write Access Login dialogDropdown Menus Programming the MegaPower CPUEasy CPU Main Screen Overview File Edit HelpMonitor Status Settings Window Display AreaChecking the System Status Explore MenuPassive Hot Switch Status Camera StatusError Log Status Configuring the System Setting System Options− Installing a Tftp server Setting System Date and Time Setting the Date and Time Using the Dialog BoxSetting the Date and Time Using the Keyboard System Date & Time dialogSetting Port Configurations Configuring the Dome/PTZ Device Direct ConnectionDome/PTZ Device Direct Connect Configuration screen Configuring Switching Creating SalvosSalvos Preset or Pattern Dropdown List Deleting Salvos or Alarm Contacts Creating ToursTours Section Event Timers Event Timers Alarm TablesDeleting Tours in the Event Timer Screen Event Timer ToursScheduling System Tours with the Event Timer Alarm TablesConfiguring Alarms Setting Up Alarm MonitorsAdding Monitor Definitions Group these monitors together Deleting Event Timers Event TimersViewing Event Timers Contact ArmingCreating Alarm Monitor/ Contact Tables Dropdown ListEmail Message dialog Email Messages Alarm MessagesDefining System Devices Defining CamerasAdding Camera Definitions Adding and Deleting Calling Contacts to Cameras onAdding and Deleting Calling Contacts to Cameras Editing Camera DefinitionsAssociating Salvo Callups to Cameras Deleting Calling ContactsDeleting Salvo Callups Adding Keyboard Definitions Adding Monitor Access to KeyboardsDefining Keyboards Editing and Deleting Keyboard DefinitionsAdding Site Access to Keyboards Adding a Range of MonitorsConfiguring Keyboard/User Keyboards and Priorities Removing Monitor or Site AccessUser Enable Logon checkbox settings Configuring the Keyboard/User Priority Settings Deleting Keyboard/User Priorities SettingsAssociating Cameras to Monitors Controlling Access with PartitionsDefining Satellite Sites Deleting Satellite SitesPartitions cameras to monitors screen Editing Camera Definitions Changing Calling ContactsAssociating Keyboards to Cameras Removing Calling ContactsAdding Cameras to Keyboards Editing Keyboard DefinitionsDeleting Keyboard Definitions Adding a Range of CamerasRemoving Monitors or Satellite Sites Access from Keyboards Associating Keyboards to MonitorsAdding Monitor Access to Keyboards Adding Monitors to KeyboardsAssociating Keyboards to Satellites Removing Monitors from KeyboardsAdding Site Access to Keyboards Associating Monitors to Cameras Adding Satellite Sites to KeyboardsRemoving Satellite Sites from Keyboards Adding Monitor Definitions Adding a Range of Cameras Adding ContactsPerforming a Ping Test Regulatory Type DeclarationsRegulatory Compliance Other DeclarationsAppendix a End User License Agreement Scope of LicenseExport Restrictions Appendix B MegaPower CPU System Defaults Appendix C MegaPower CPU Front Panel LCD Menu Structure Appendix D Port Number Assignments Purpose Protocol Port DescriptionAppendix E Auxiliary Key Code Functions F1 Special Function KeysF2 Special Function Keys 61-F2 55-F260-F2 62-F2Appendix F Configuring Video Loss Detection Video Loss Detection dropdown menuMegapower CPU ADMINISTRATOR’S Guide Alarm Arming and Response Appendix G Alarm Programming Overview Alarm Receipt Alarm Display IndicatorsAlarm Clearance Method Alarm Display MethodAlarm Queuing Method Appendix H Monitor Arming MethodsMegapower CPU ADMINISTRATOR’S Guide Single Display, Hold Queuing Appendix I Monitor Arming CodesSingle Display, Sequence Queuing Block Display, Sequence QueuingBlock Display, Hold Queuing Dual Display, Hold and Sequence QueuingAppendix J Alarm Arming Notes Appendix K Satellite Configuration Overview Setting Up Satellite SitesSatellite Site Connections Site 1 Source Site Site 1 Source and Receiving Site 2 Source and Receiving Page 8200-0421-03 G