American Dynamics ADMPCPU manual Adding and Deleting Calling Contacts to Cameras

Page 46

Note: By default, pseudo numbers in this dialog box match the physical camera numbers. In all other screens and dialogs, references to camera numbers are actually references to the defined pseudo numbers.

Title 1 – You can create a two-line title for each camera that will display on the monitor when the camera is called. Title 1 is the upper line of the title and can be up to eight characters or digits in length with the pseudo number appended to the title. Titles over eight characters are truncated.

Title 2 – Title 2 allows you to create the lower line of a two-line camera title. Title 2 can be up to eight characters or digits in length.

Video Loss Detection – Provides video loss detection alarming. You can set video loss detection for the following conditions:

Off – Video loss detection not enabled

Sync – To detect the presence or loss of the synchronized portion of the video signal

Low – To detect low picture content

Medium – To detect medium picture content

High – To detect high picture content

Note: For detailed information on configuring for video loss detection, go to APPENDIX F: Configuring Video Loss Detection on page 71.

Site – Identifies the remote site that provides the video trunk inputs to the selected local camera.

Output – Identifies the monitor output from the remote site that is connected to the selected local camera input.

Alarm Number – Specifies an alarm contact number to activate when video loss is detected on this video input. See alarm contact definitions and APPENDIX F: Configuring Video Loss Detection on page 71.

3.Click OK to display the new definition or Cancel to close the dialog box without displaying the definition.

Note: Remember to save or transfer your changes before closing EASY CPU.

Editing Camera Definitions

Once a camera is defined, you can edit the definition by highlighting the information in the desired field and entering new information.

For example, to position Title1 on the monitor, click on the Center Title1 field, and choose the desired title position from the dropdown menu that appears: Left, Center, Right, or None (no title will be displayed).

Adding and Deleting Calling Contacts to Cameras

The Calling Contacts tab allows you to specify the alarm contacts associated with the highlighted camera.

To view and edit this tab, double-click on the Calling Contacts field in the highlighted camera row.

Figure 90. Cameras Calling Contacts tab screen

The Calling Contacts tab contains the following fields:

Contact No. – Number of the alarm contact associated with the camera

Preset or Pattern – Pattern or preset number associated with the camera

Link – Choose either No, Yes, Wired, No Group Ack, Yes Group Ack, or Wired Group Ack

Aux – Choose either Don’t Care, Aux 1 On, Aux 2 On, Aux 3 On, Aux 4 On, Aux 1 Off, Aux 2 Off, Aux 3 Off, or Aux 4 Off

Dwell – Enter the dwell time in seconds

Alarm Message – Enter the alarm message number to be associated with the camera.

Note: Alarm messages are first created in the Alarms Alarm Messages screen.

Email Message – Enter the Email message number to be associated with the camera.

Note: Email messages are first created in the Alarms – Email Messages screen.

To close the Calling Contacts tab, click the Close

Grid button on the right side of the screen.

MEGAPOWER CPU ADMINISTRATOR’S GUIDE

8200-0421-03, REV. G

44 of 82

Image 46
Contents MegaPower CPU Page About the Product MegaPower CPUAbout this Guide Contents Removing Monitors or Satellite Sites Access From Keyboards MegaPower 3200 Video-Matrix Cctv System Dual CPU MegaPower CPU Front PanelSystem Components MegaPower System OverviewCPU Rear Panel System CapabilitiesSystem Features Compatible System KeyboardsAdministrator Tasks Operator TasksDirect Connection Initializing the SystemUnderstanding the Screen Icons RS-232 Port S3 SoftwareEthernet Network Connection Ethernet Port Easy CPU SoftwareStandalone Mpcpu Enter Using an IP Address Assigned by the Network Dhcp ServerADCC1100 ADCC0200/0300Using a Static IP Address System Menu screenFirewall Setup Read CycleBeginning the Installation Installing Easy CPUError Message Example Write CycleChoose Setup Language dialog Language, go to Appendix a End User License Agreement onLicense Agreement screen Configuring Preferences Starting Easy CPUViewing Configuration File Properties Saving Data on the Hard DriveFactory-Default or Existing Configuration Data in CPU Retrieving Configuration DataConfiguration Data File Only in PC Write to Mpcpu and/or Save Configuration To File dialog New Configuration File Adding a User Login Login Manager dialogLogging in Users for CPU Read/Write Access Login dialogDropdown Menus Programming the MegaPower CPUEasy CPU Main Screen Overview File Edit HelpMonitor Status Settings Window Display AreaChecking the System Status Explore MenuPassive Hot Switch Status Camera StatusError Log Status Setting System Options Configuring the System− Installing a Tftp server Setting System Date and Time Setting the Date and Time Using the Dialog BoxSetting the Date and Time Using the Keyboard System Date & Time dialogSetting Port Configurations Configuring the Dome/PTZ Device Direct ConnectionDome/PTZ Device Direct Connect Configuration screen Configuring Switching Creating SalvosSalvos Preset or Pattern Dropdown List Creating Tours Deleting Salvos or Alarm ContactsTours Section Event Timers Event Timers Alarm TablesDeleting Tours in the Event Timer Screen Event Timer ToursScheduling System Tours with the Event Timer Alarm TablesSetting Up Alarm Monitors Configuring AlarmsAdding Monitor Definitions Group these monitors together Deleting Event Timers Event TimersViewing Event Timers Contact ArmingCreating Alarm Monitor/ Contact Tables Dropdown ListEmail Message dialog Email Messages Alarm MessagesDefining System Devices Defining CamerasAdding Camera Definitions Adding and Deleting Calling Contacts to Cameras onAdding and Deleting Calling Contacts to Cameras Editing Camera DefinitionsDeleting Calling Contacts Associating Salvo Callups to CamerasDeleting Salvo Callups Adding Keyboard Definitions Adding Monitor Access to KeyboardsDefining Keyboards Editing and Deleting Keyboard DefinitionsAdding Site Access to Keyboards Adding a Range of MonitorsRemoving Monitor or Site Access Configuring Keyboard/User Keyboards and PrioritiesUser Enable Logon checkbox settings Configuring the Keyboard/User Priority Settings Deleting Keyboard/User Priorities SettingsAssociating Cameras to Monitors Controlling Access with PartitionsDefining Satellite Sites Deleting Satellite SitesPartitions cameras to monitors screen Editing Camera Definitions Changing Calling ContactsAssociating Keyboards to Cameras Removing Calling ContactsAdding Cameras to Keyboards Editing Keyboard DefinitionsDeleting Keyboard Definitions Adding a Range of CamerasRemoving Monitors or Satellite Sites Access from Keyboards Associating Keyboards to MonitorsAdding Monitor Access to Keyboards Adding Monitors to KeyboardsAssociating Keyboards to Satellites Removing Monitors from KeyboardsAdding Site Access to Keyboards Adding Satellite Sites to Keyboards Associating Monitors to CamerasRemoving Satellite Sites from Keyboards Adding Monitor Definitions Adding a Range of Cameras Adding ContactsPerforming a Ping Test Regulatory Type DeclarationsRegulatory Compliance Other DeclarationsAppendix a End User License Agreement Scope of LicenseExport Restrictions Appendix B MegaPower CPU System Defaults Appendix C MegaPower CPU Front Panel LCD Menu Structure Appendix D Port Number Assignments Purpose Protocol Port DescriptionF1 Special Function Keys Appendix E Auxiliary Key Code FunctionsF2 Special Function Keys 61-F2 55-F260-F2 62-F2Appendix F Configuring Video Loss Detection Video Loss Detection dropdown menuMegapower CPU ADMINISTRATOR’S Guide Alarm Arming and Response Appendix G Alarm Programming OverviewAlarm Receipt Alarm Display IndicatorsAlarm Clearance Method Alarm Display MethodAlarm Queuing Method Appendix H Monitor Arming MethodsMegapower CPU ADMINISTRATOR’S Guide Single Display, Hold Queuing Appendix I Monitor Arming CodesSingle Display, Sequence Queuing Block Display, Sequence QueuingBlock Display, Hold Queuing Dual Display, Hold and Sequence QueuingAppendix J Alarm Arming Notes Appendix K Satellite Configuration Overview Setting Up Satellite SitesSatellite Site Connections Site 1 Source Site Site 1 Source and Receiving Site 2 Source and Receiving Page 8200-0421-03 G