American Dynamics ADMPCPU manual Administrator Tasks, Operator Tasks

Page 9

Priority Access – Priority levels assigned to keyboards and users allow higher priority users to capture and lock out cameras (pan, tilt, lens and auxiliary control) from lower priority users. The system allows up to eight priority levels.

Recorder control – Operators can control recording devices (DVR, VCR or other current and future recording devices) through keyboard commands.

Selectable Date/Time Display – The system’s date can be programmed to display in the following formats: MM/DD/YY, DD/MM/YY or YY/MM/DD. Time is displayed in a 24-hour format.

System Salvos – A System Salvo is a group of local cameras programmed for simultaneous call- up to a contiguous group of local monitors. You can program up to 64 system salvos with a maximum of sixteen cameras in each Salvo.

System Tours – A System Tour is a sequence of cameras programmed from EASY CPU for an individual monitor. System Tours cannot be altered by keyboard commands and are therefore more permanent in nature than Monitor Tours. You can create up to 64 System Tours, each with up to 64 cameras. You determine the dwell time, Preset camera scene and auxiliary action for each camera.

Timed Events – An Event is a user-defined time slot programmed for automatic call up of System Tours and Alarm Contact Tables. You can program up to 35 local Event Timers with each set for call ups at a specific time of day, on any days of the week and week after week.

User-Assigned Camera Numbers – You can assign user-defined pseudo camera numbers to any camera input. Pseudo numbers identify cameras by function or location, rather than by its input number on the switcher. For example, you could assign pseudo numbers 101 through 110 for cameras on the first floor of a multi-floor building, 201 through 210 for second floor cameras, 301 through 310 for third floor cameras, and so on.

Video Loss Detection – When equipped with the optional Video Loss Detector module, the system can detect the presence or loss of a video signal for each local camera. You determine the sync or video signal level at which a loss of video is detected.

Video Switcher Control – The MegaPower CPU controls the video switching of all local and remote cameras to all local monitors. Switching is performed in response to operator keyboard request or by automatic action via Tours, System Salvos, Timed Events, or Alarm Response.

Satellite Site Support – Up to 30 individual MegaPower 3200 video-matrix CCTV systems can be linked into a satellite network. For more detailed information on satellite systems, go to

APPENDIX K: Satellite Configuration Overview on page 79.

Administrator Tasks

A system administrator is an individual assigned to manage the MegaPower 3200 video-matrix CCTV system. This person often participates in pre- installation planning and should be familiar with the system’s capabilities, equipment, camera inputs, monitors, satellite locations, and programming.

The administrator prepares the system for operators to use. This preparation includes the following:

Configuring the system

Creating operator IDs, scheduling operator shifts, and determining access levels

Creating camera names and pseudo numbers

Creating site numbers

Creating alarm responses

Maintaining a list of alarms and auxiliaries

Setting Event times

Creating Salvos

Creating system Tours

Operator Tasks

Operators perform the day-to-day task of video surveillance using keyboards connected to the MegaPower CPU. They select and control cameras, create and run automated camera actions, acknowledge alarm activities, adjust monitors, and take appropriate action based on what is observed. Operators can also perform limited programming functions through their keyboards.

Refer to the MegaPower CPU Operator’s Guide, 8200-0421-02, for additional information.

MEGAPOWER CPU ADMINISTRATOR’S GUIDE

8200-0421-03, REV. G

7 of 82

Image 9
Contents MegaPower CPU Page MegaPower CPU About the ProductAbout this Guide Contents Removing Monitors or Satellite Sites Access From Keyboards MegaPower CPU Front Panel MegaPower 3200 Video-Matrix Cctv System Dual CPUCPU Rear Panel MegaPower System OverviewSystem Components System CapabilitiesCompatible System Keyboards System FeaturesOperator Tasks Administrator TasksUnderstanding the Screen Icons Initializing the SystemDirect Connection RS-232 Port S3 SoftwareEthernet Port Easy CPU Software Ethernet Network ConnectionADCC1100 Using an IP Address Assigned by the Network Dhcp ServerStandalone Mpcpu Enter ADCC0200/0300System Menu screen Using a Static IP AddressRead Cycle Firewall SetupError Message Example Installing Easy CPUBeginning the Installation Write CycleLanguage, go to Appendix a End User License Agreement on Choose Setup Language dialogLicense Agreement screen Starting Easy CPU Configuring PreferencesSaving Data on the Hard Drive Viewing Configuration File PropertiesRetrieving Configuration Data Factory-Default or Existing Configuration Data in CPUConfiguration Data File Only in PC Write to Mpcpu and/or Save Configuration To File dialog New Configuration File Login Manager dialog Adding a User LoginLogin dialog Logging in Users for CPU Read/Write AccessEasy CPU Main Screen Overview Programming the MegaPower CPUDropdown Menus File Edit HelpChecking the System Status Settings Window Display AreaMonitor Status Explore MenuCamera Status Passive Hot Switch StatusError Log Status Configuring the System Setting System Options− Installing a Tftp server Setting the Date and Time Using the Dialog Box Setting System Date and TimeSystem Date & Time dialog Setting the Date and Time Using the KeyboardConfiguring the Dome/PTZ Device Direct Connection Setting Port ConfigurationsDome/PTZ Device Direct Connect Configuration screen Creating Salvos Configuring SwitchingSalvos Preset or Pattern Dropdown List Deleting Salvos or Alarm Contacts Creating ToursTours Section Event Timers Alarm Tables Event TimersScheduling System Tours with the Event Timer Event Timer ToursDeleting Tours in the Event Timer Screen Alarm TablesConfiguring Alarms Setting Up Alarm MonitorsAdding Monitor Definitions Group these monitors together Viewing Event Timers Event TimersDeleting Event Timers Contact ArmingDropdown List Creating Alarm Monitor/ Contact TablesEmail Message dialog Defining System Devices Alarm MessagesEmail Messages Defining CamerasAdding and Deleting Calling Contacts to Cameras on Adding Camera DefinitionsEditing Camera Definitions Adding and Deleting Calling Contacts to CamerasAssociating Salvo Callups to Cameras Deleting Calling ContactsDeleting Salvo Callups Defining Keyboards Adding Monitor Access to KeyboardsAdding Keyboard Definitions Editing and Deleting Keyboard DefinitionsAdding a Range of Monitors Adding Site Access to KeyboardsConfiguring Keyboard/User Keyboards and Priorities Removing Monitor or Site AccessUser Enable Logon checkbox settings Deleting Keyboard/User Priorities Settings Configuring the Keyboard/User Priority SettingsDefining Satellite Sites Controlling Access with PartitionsAssociating Cameras to Monitors Deleting Satellite SitesPartitions cameras to monitors screen Changing Calling Contacts Editing Camera DefinitionsRemoving Calling Contacts Associating Keyboards to CamerasDeleting Keyboard Definitions Editing Keyboard DefinitionsAdding Cameras to Keyboards Adding a Range of CamerasAssociating Keyboards to Monitors Removing Monitors or Satellite Sites Access from KeyboardsAdding Monitors to Keyboards Adding Monitor Access to KeyboardsRemoving Monitors from Keyboards Associating Keyboards to SatellitesAdding Site Access to Keyboards Associating Monitors to Cameras Adding Satellite Sites to KeyboardsRemoving Satellite Sites from Keyboards Adding Monitor Definitions Adding Contacts Adding a Range of CamerasPerforming a Ping Test Regulatory Compliance DeclarationsRegulatory Type Other DeclarationsScope of License Appendix a End User License AgreementExport Restrictions Appendix B MegaPower CPU System Defaults Appendix C MegaPower CPU Front Panel LCD Menu Structure Purpose Protocol Port Description Appendix D Port Number AssignmentsAppendix E Auxiliary Key Code Functions F1 Special Function KeysF2 Special Function Keys 60-F2 55-F261-F2 62-F2Video Loss Detection dropdown menu Appendix F Configuring Video Loss DetectionMegapower CPU ADMINISTRATOR’S Guide Alarm Receipt Appendix G Alarm Programming OverviewAlarm Arming and Response Alarm Display IndicatorsAlarm Queuing Method Alarm Display MethodAlarm Clearance Method Appendix H Monitor Arming MethodsMegapower CPU ADMINISTRATOR’S Guide Single Display, Sequence Queuing Appendix I Monitor Arming CodesSingle Display, Hold Queuing Block Display, Sequence QueuingDual Display, Hold and Sequence Queuing Block Display, Hold QueuingAppendix J Alarm Arming Notes Setting Up Satellite Sites Appendix K Satellite Configuration OverviewSatellite Site Connections Site 1 Source Site Site 1 Source and Receiving Site 2 Source and Receiving Page 8200-0421-03 G