American Dynamics ADMPCPU manual Using a Static IP Address, System Menu screen

Page 13

Dual MPCPU: Enter 100 for the selected MegaPower CPU, or enter 101 for the Standby MP CPU.

d.Press the Ack key located in the lower right corner.

The System Menu appears on the LCD screen (Figure 12).

Note: To exit the LCD Menu Mode, press the Menu key.

Figure 12. System Menu screen

3.Press Enter to choose Addressing. The Address Menu screen appears.

Figure 13. Address Menu screen

4.Press Enter to choose IP Address. The IP Address screen appears.

Figure 14. IP Address screen

5.Scroll down to Set IP Addr and press Enter. The Set IP Address screen appears.

Figure 15. Set IP Address screen

6.Scroll down to DHCP and press Enter. The DHCP Setting screen appears.

Figure 16. DHCP Setting screen

7.Press Enter to choose Enable.

8.Exit from the MegaPower CPU menu system.

Using a Static IP Address

To set up the MegaPower CPU for a static IP address:

1.Connect a keyboard to an RS-232 port on the MegaPower CPU. Ensure the baud rates match for the keyboard and CPU port in use.

2.Use the following instructions to provide the key sequences for each supported keyboard:

AD2088:

a.Place the keyboard in Menu Mode by turning the keyswitch to MENU. The CAMERA LEDs on the keyboard display P6.

b.Enter one of the following number sequences for your MegaPower CPU installation:

Standalone MPCPU: Enter 100.

Dual MPCPU: Enter 100 for the selected MegaPower CPU, or enter 101 for the Standby MP CPU.

c.Press the ENTER key, which is located above the joystick. “ENTER” is stenciled on the front face of the key; the top of the key may be labeled either PRESET or SHOT.

The CAMERA LEDs on the keyboard will only display 7P if the selected CPU is accessed.

ADCC1100:

a.Place the keyboard in Program Mode by pressing its softkey.

Note: To display and enter Program Mode, you must insert a Smartcard that has administrator privileges.

b.Press the Matrix Menus softkey.

c.Enter one of the following number sequences for your MegaPower CPU installation:

Standalone MPCPU: Enter 100.

Dual MPCPU: Enter 100 for the selected MegaPower CPU, or enter 101 for the Standby MP CPU.

d.Press the Enter softkey.

ADCC0200/0300:

Notes: In RS–232 mode, the ADCC0200 keyboard does not have matrix menu access

MEGAPOWER CPU ADMINISTRATOR’S GUIDE

8200-0421-03, REV. G

11 of 82

Image 13
Contents MegaPower CPU Page About the Product MegaPower CPUAbout this Guide Contents Removing Monitors or Satellite Sites Access From Keyboards MegaPower CPU Front Panel MegaPower 3200 Video-Matrix Cctv System Dual CPUCPU Rear Panel MegaPower System OverviewSystem Components System CapabilitiesCompatible System Keyboards System FeaturesOperator Tasks Administrator TasksUnderstanding the Screen Icons Initializing the SystemDirect Connection RS-232 Port S3 SoftwareEthernet Port Easy CPU Software Ethernet Network ConnectionADCC1100 Using an IP Address Assigned by the Network Dhcp ServerStandalone Mpcpu Enter ADCC0200/0300System Menu screen Using a Static IP AddressRead Cycle Firewall SetupError Message Example Installing Easy CPUBeginning the Installation Write CycleLanguage, go to Appendix a End User License Agreement on Choose Setup Language dialogLicense Agreement screen Starting Easy CPU Configuring PreferencesSaving Data on the Hard Drive Viewing Configuration File PropertiesFactory-Default or Existing Configuration Data in CPU Retrieving Configuration DataConfiguration Data File Only in PC Write to Mpcpu and/or Save Configuration To File dialog New Configuration File Login Manager dialog Adding a User LoginLogin dialog Logging in Users for CPU Read/Write AccessEasy CPU Main Screen Overview Programming the MegaPower CPUDropdown Menus File Edit HelpChecking the System Status Settings Window Display AreaMonitor Status Explore MenuCamera Status Passive Hot Switch StatusError Log Status Setting System Options Configuring the System− Installing a Tftp server Setting the Date and Time Using the Dialog Box Setting System Date and TimeSystem Date & Time dialog Setting the Date and Time Using the KeyboardConfiguring the Dome/PTZ Device Direct Connection Setting Port ConfigurationsDome/PTZ Device Direct Connect Configuration screen Creating Salvos Configuring SwitchingSalvos Preset or Pattern Dropdown List Creating Tours Deleting Salvos or Alarm ContactsTours Section Event Timers Alarm Tables Event TimersScheduling System Tours with the Event Timer Event Timer ToursDeleting Tours in the Event Timer Screen Alarm TablesSetting Up Alarm Monitors Configuring AlarmsAdding Monitor Definitions Group these monitors together Viewing Event Timers Event TimersDeleting Event Timers Contact ArmingDropdown List Creating Alarm Monitor/ Contact TablesEmail Message dialog Defining System Devices Alarm MessagesEmail Messages Defining CamerasAdding and Deleting Calling Contacts to Cameras on Adding Camera DefinitionsEditing Camera Definitions Adding and Deleting Calling Contacts to CamerasDeleting Calling Contacts Associating Salvo Callups to CamerasDeleting Salvo Callups Defining Keyboards Adding Monitor Access to KeyboardsAdding Keyboard Definitions Editing and Deleting Keyboard DefinitionsAdding a Range of Monitors Adding Site Access to KeyboardsRemoving Monitor or Site Access Configuring Keyboard/User Keyboards and PrioritiesUser Enable Logon checkbox settings Deleting Keyboard/User Priorities Settings Configuring the Keyboard/User Priority SettingsDefining Satellite Sites Controlling Access with PartitionsAssociating Cameras to Monitors Deleting Satellite SitesPartitions cameras to monitors screen Changing Calling Contacts Editing Camera DefinitionsRemoving Calling Contacts Associating Keyboards to CamerasDeleting Keyboard Definitions Editing Keyboard DefinitionsAdding Cameras to Keyboards Adding a Range of CamerasAssociating Keyboards to Monitors Removing Monitors or Satellite Sites Access from KeyboardsAdding Monitors to Keyboards Adding Monitor Access to KeyboardsRemoving Monitors from Keyboards Associating Keyboards to SatellitesAdding Site Access to Keyboards Adding Satellite Sites to Keyboards Associating Monitors to CamerasRemoving Satellite Sites from Keyboards Adding Monitor Definitions Adding Contacts Adding a Range of CamerasPerforming a Ping Test Regulatory Compliance DeclarationsRegulatory Type Other DeclarationsScope of License Appendix a End User License AgreementExport Restrictions Appendix B MegaPower CPU System Defaults Appendix C MegaPower CPU Front Panel LCD Menu Structure Purpose Protocol Port Description Appendix D Port Number AssignmentsF1 Special Function Keys Appendix E Auxiliary Key Code FunctionsF2 Special Function Keys 60-F2 55-F261-F2 62-F2Video Loss Detection dropdown menu Appendix F Configuring Video Loss DetectionMegapower CPU ADMINISTRATOR’S Guide Alarm Receipt Appendix G Alarm Programming OverviewAlarm Arming and Response Alarm Display IndicatorsAlarm Queuing Method Alarm Display MethodAlarm Clearance Method Appendix H Monitor Arming MethodsMegapower CPU ADMINISTRATOR’S Guide Single Display, Sequence Queuing Appendix I Monitor Arming CodesSingle Display, Hold Queuing Block Display, Sequence QueuingDual Display, Hold and Sequence Queuing Block Display, Hold QueuingAppendix J Alarm Arming Notes Setting Up Satellite Sites Appendix K Satellite Configuration OverviewSatellite Site Connections Site 1 Source Site Site 1 Source and Receiving Site 2 Source and Receiving Page 8200-0421-03 G