AC International SV01B, V0100 Drive Displays and Modes of Operation, Parameter setting

Page 15

Commissioning

4.2Drive Displays and Modes of Operation

Speed Mode Display

In the standard mode of operation, the drive frequency output is set directly by the selected reference (keypad, analog reference, etc.). In this mode, the drive display will show the drive’s output frequency.

PID Mode Display

When the PID mode is enabled and active, the normal run display shows the actual PID setpoint. When PID mode is not active, the display returns to showing the drive’s output frequency.

Torque Mode Display

When the drive is operating in Vector Torque mode, the normal run display shows the drive’s output frequency.

4.3Parameter setting

Status/fault messages

Change Parameters

StoP

M

P194 = 0000

p100

60.0

 

 

 

 

 

PASS

 

M

CL

 

 

p104

 

 

 

Err

0225

 

15 s

 

 

 

 

 

 

M

 

 

F.AF

 

 

p541

 

 

 

F.UF

60 s

 

20.0

12.0

M

V0106

4.4Electronic programming module (EPM)

Tmd007

The EPM contains the drives operational memory. Parameter settings are stored in the EPM and setting changes are made to the “User settings” in the EPM.

An optional EPM Programmer (model EEPM1RA) is available that allows:

An EPM to be copied directly to another EPM.

An EPM to be copied to the memory of the EPM Programmer.

Stored files can be modified in the EPM Programmer.

Stored files can be copied to another EPM.

As the EPM Programmer is battery operated, parameter settings can be copied to an EPM and inserted into a drive without power being applied to the drive. This means that the drive will be fully operational with the new settings on the next application of power.

Additionally, when the drives parameter settings are burned into an EPM with the EPM Programmer, the settings are saved in two distinct locations; the “User settings” and the “OEM default settings”. While the User settings can be modified in the drive, the OEM settings cannot. Thus, the drive can be reset not only to the “factory” drive default settings (shown in this manual), but can be set to the Original Machine settings as programmed by the OEM.

While the EPM can be removed for copying or to use in another drive, it must be

installed for the drive to operate (a missing EPM will trigger an fault).

14

ENGLISH

Image 15
Contents Operating Instructions Contents Visible deficiencies / incompleteness immediately to your About these instructionsClaim Visible transport damage immediately to the forwarderElectrical connection Safety informationInstallation GeneralWarns of potential damage to material Icon Signal WordsOperation Warns of impending dangerStandards and application conditions Technical dataRatings 120VAC Doubler / 240VAC Models240VAC Models Drive Derating Mains Output CurrentInstallation Dimensions and mountingType Mains connection to 240VAC Single-Phase Supply Electrical installationPower Connections Mains connection to 120VAC Single-Phase SupplyESV…N06T… 3/PE AC Mains connection to Three-Phase SupplyMotor Connection Mains and Motor Terminations400V Fuses/cable cross-sectionsRecommendations Type 240VControl terminals 13AAssertion level of digital inputs Local Mode P100 = 0, 4, this button will start the drive CommissioningLocal Keypad & Display Parameter setting Drive Displays and Modes of OperationElectronic programming module EPM Basic Setup Parameters Code Possible Settings No. Name Default SelectionParameter menu Acceleration Selection Drives except when using resetDefault setting is Motor Overload Minimum P103Upon a stop command, allowing Faults, or when power is appliedPrior to faulting or power loss Power-up2 I/O Setup Parameters Code Possible Settings Name Default Selection Network Control Active Standard Reference Active De-energizes when PID feedbackAttempts fail Active for start controlNetwork Activated Requires optional communication VDC Load VDC Torque VDC Power kWTB-14 Output Dynamic BrakingCode Advanced Setup ParametersDrive displays , and either CLim When the limit is reached,Display Depends on mode of operation See Section Slip 10.0Is installed Reset to 60 Hz default settings See NoteFault circuitry may be disabled! Check P100 and P121...P123 Displayed when P199 is set to 1 orPID Parameters Setpoint by more than the value Sleep DelayP242 or when the PID loop P200 = 0…2 Drive will start againVector Parameters If P300 = 2...5, motor calibration Calibration Enabled Must be programmed first An alternatingMotor Stator 4.00 Current Loop 9990Network Parameters Diagnostic ParametersKeypad Status Display Terminal and Protection Status DisplayTroubleshooting and Diagnostics Status/Warning MessagesStatus / Warning Cause Remedy Format = Drive Configuration MessagesExample Stop Source DisplayFault Cause Remedy Fault MessagesIs set to 13 or Digital Input More than one digital input set forMOP function Up, Down Change PID setpoint referenceVerify drive and motor are proper Page SV01B

V0100, SV01B specifications

The AC International SV01B and V0100 represent a significant advancement in the realm of audio technology, specifically tailored for audiophiles and professionals seeking high-fidelity sound reproduction. These models have garnered attention for their impeccable engineering and innovative features designed to enhance the listening experience.

One of the standout characteristics of the SV01B is its superior sound quality, achieved through high-resolution audio capabilities. This model supports various audio formats, ensuring that users can enjoy music in its purest form. The SV01B employs advanced digital signal processing (DSP) that optimizes audio performance, reducing distortion and maintaining clarity at high volumes. Coupled with a robust amplifier, the SV01B delivers deep bass and crystal-clear highs, making it suitable for listening to a range of genres from classical to modern electronic music.

The V0100, on the other hand, brings together cutting-edge wireless technology with exceptional sound. It incorporates Bluetooth 5.0, ensuring a stable and high-quality connection with compatible devices. This feature allows users to experience seamless streaming without the hassle of tangled wires. The V0100 also supports aptX and AAC codecs, enabling low-latency audio playback, which is particularly beneficial for video content and gaming. Additionally, its multi-device connection capability allows users to switch between devices effortlessly, enhancing convenience.

Both the SV01B and V0100 showcase elegant designs that blend practicality with aesthetics. The chassis of these models is crafted from high-grade materials, providing durability while minimizing resonance. Furthermore, they feature intuitive controls, making it easy to adjust settings or switch tracks without interrupting the listening flow.

Battery life is another significant advantage of the V0100, which offers an impressive runtime on a single charge, ensuring that users can enjoy extended listening sessions without frequent recharging. The LED indicators provide clear feedback on connectivity and battery status, enhancing user experience.

In conclusion, the AC International SV01B and V0100 are remarkable audio devices that combine outstanding sound quality, advanced technology, and user-friendly features. They cater to both casual listeners and dedicated audiophiles, making them an excellent choice for anyone looking to elevate their audio experience.