AC International V0100, SV01B operating instructions Code Possible Settings Name Default Selection

Page 20

Commissioning

Code

Possible Settings

No.

Name

Default

Selection

 

 

 

 

IMPORTANT

Note

When input is activated, settings 1...7 override P101

When TB-13A...TB-13C are configured for Auto References other than MOP, TB-13C overrides TB-13B, and TB-13B overrides TB-13A. Any other Auto Reference will have priority over MOP.

Settings 10...14 are only valid in Terminal Strip mode (P100 = 1, 4, 5)

If Start/Run/Jog Forward and Start/Run/Jog Reverse are both activated, drive will STOP

If Jog input is activated while the drive is running, the drive will enter Jog mode; when Jog input is deactivated, drive will STOP

An fault will occur if the Assertion Level switch (ALsw) position does not match the P120 setting and any of the digital inputs (P121...P123) are set to a value other than 0.

An fault will occur under the following conditions:

-TB-13A...TB-13C settings are duplicated (each setting, except 0 and 3, can only be used once)

-One input is set to “MOP Up” and another is not set to “MOP Down”, or vice-versa.

-One input is set to 10 and another input is set to 11…14.

-One input is set to 11 or 12 and another input is set for 13 or 14.

Typical control circuits are shown below:

-If any input is set to 10, 12 or 14, P112 must be set to 1 for Reverse action to function.

Run / Stop

with Direction

P121 = 10

1 4 13A

STOP FWD

RUN REV

Start Forward /

Start Reverse

P121 = 11, P122 = 12

1

4

 

 

13A

13B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FWD

STOP REV

Run Forward /

Run Reverse

P121 = 13, P122 = 14

1

4

13A

13B

RUN

FWD RUN

REV

 

Acceleration

20.0

0.0

{s}

3600

Selected using TB-13A...TB-13C

 

Time 2

 

 

 

 

 

(P121...P123 =

17)

 

 

 

 

 

 

 

 

 

• For S-ramp accel/decel, adjust P106

 

Deceleration

20.0

0.0

{s}

3600

 

 

 

 

 

 

 

 

 

 

Time 2

 

 

 

 

 

 

 

 

 

 

 

 

 

Deceleration

20.0

0.0

{s}

3600

Selected using TB-13A...TB-13C

 

Time for Auxiliary

 

 

 

 

 

(P121...P123 =

19).

 

 

 

 

Ramp to Stop

 

 

 

 

• For S-ramp accel/decel, adjust P106

 

 

 

 

 

 

• Once executed, this ramp time has

 

 

 

 

 

 

 

priority over P105 and P126.

 

Preset Speed #1

0.0

0.0

{Hz}

500

 

 

 

 

 

 

 

 

 

 

PRESET

13A

 

13B

13C

 

 

 

 

 

 

 

 

 

 

 

Preset Speed #2

0.0

0.0

{Hz}

500

 

SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

X

 

 

--

--

 

 

Preset Speed #3

0.0

0.0

{Hz}

500

 

 

 

 

 

2

--

 

 

X

--

 

 

 

 

 

 

 

 

 

 

 

 

Preset Speed #4

0.0

0.0

{Hz}

500

 

 

 

 

 

 

 

 

 

 

3

--

 

 

--

X

 

 

 

 

 

 

 

 

4

X

 

 

X

--

 

 

Preset Speed #5

0.0

0.0

{Hz}

500

 

 

 

 

 

5

X

 

 

--

X

 

 

 

 

 

 

 

 

 

 

 

 

Preset Speed #6

0.0

0.0

{Hz}

500

 

 

 

 

 

6

--

 

 

X

X

 

 

 

 

 

 

 

 

 

 

 

 

Preset Speed #7

0.0

0.0

{Hz}

500

 

7

X

 

 

X

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

19

Image 20
Contents Operating Instructions Contents About these instructions ClaimVisible transport damage immediately to the forwarder Visible deficiencies / incompleteness immediately to yourSafety information InstallationGeneral Electrical connectionIcon Signal Words OperationWarns of impending danger Warns of potential damage to materialTechnical data Standards and application conditions240VAC Models Ratings120VAC Doubler / 240VAC Models Mains Output Current Drive DeratingType InstallationDimensions and mounting Electrical installation Power ConnectionsMains connection to 120VAC Single-Phase Supply Mains connection to 240VAC Single-Phase SupplyMains connection to Three-Phase Supply Motor ConnectionMains and Motor Terminations ESV…N06T… 3/PE ACFuses/cable cross-sections Recommendations Type240V 400VAssertion level of digital inputs Control terminals13A Local Keypad & Display Local Mode P100 = 0, 4, this button will start the driveCommissioning Electronic programming module EPM Parameter settingDrive Displays and Modes of Operation Parameter menu Basic Setup ParametersCode Possible Settings No. Name Default Selection Selection Drives except when using reset Default setting is Motor OverloadMinimum P103 AccelerationFaults, or when power is applied Prior to faulting or power lossPower-up Upon a stop command, allowing2 I/O Setup Parameters Code Possible Settings Name Default Selection De-energizes when PID feedback Attempts failActive for start control Network Control Active Standard Reference ActiveVDC Load VDC Torque VDC Power kW TB-14 OutputDynamic Braking Network Activated Requires optional communicationAdvanced Setup Parameters CodeCLim When the limit is reached, Display Depends on mode of operation See SectionSlip 10.0 Drive displays , and eitherReset to 60 Hz default settings See Note Fault circuitry may be disabled! Check P100 and P121...P123Displayed when P199 is set to 1 or Is installedPID Parameters Sleep Delay P242 or when the PID loopP200 = 0…2 Drive will start again Setpoint by more than the valueVector Parameters Calibration Enabled Must be programmed first An alternating Motor Stator 4.00Current Loop 9990 If P300 = 2...5, motor calibrationDiagnostic Parameters Network ParametersTerminal and Protection Status Display Keypad Status DisplayStatus / Warning Cause Remedy Troubleshooting and DiagnosticsStatus/Warning Messages Drive Configuration Messages ExampleStop Source Display Format =Fault Messages Fault Cause RemedyDigital Input More than one digital input set for MOP function Up, DownChange PID setpoint reference Is set to 13 orVerify drive and motor are proper Page SV01B

V0100, SV01B specifications

The AC International SV01B and V0100 represent a significant advancement in the realm of audio technology, specifically tailored for audiophiles and professionals seeking high-fidelity sound reproduction. These models have garnered attention for their impeccable engineering and innovative features designed to enhance the listening experience.

One of the standout characteristics of the SV01B is its superior sound quality, achieved through high-resolution audio capabilities. This model supports various audio formats, ensuring that users can enjoy music in its purest form. The SV01B employs advanced digital signal processing (DSP) that optimizes audio performance, reducing distortion and maintaining clarity at high volumes. Coupled with a robust amplifier, the SV01B delivers deep bass and crystal-clear highs, making it suitable for listening to a range of genres from classical to modern electronic music.

The V0100, on the other hand, brings together cutting-edge wireless technology with exceptional sound. It incorporates Bluetooth 5.0, ensuring a stable and high-quality connection with compatible devices. This feature allows users to experience seamless streaming without the hassle of tangled wires. The V0100 also supports aptX and AAC codecs, enabling low-latency audio playback, which is particularly beneficial for video content and gaming. Additionally, its multi-device connection capability allows users to switch between devices effortlessly, enhancing convenience.

Both the SV01B and V0100 showcase elegant designs that blend practicality with aesthetics. The chassis of these models is crafted from high-grade materials, providing durability while minimizing resonance. Furthermore, they feature intuitive controls, making it easy to adjust settings or switch tracks without interrupting the listening flow.

Battery life is another significant advantage of the V0100, which offers an impressive runtime on a single charge, ensuring that users can enjoy extended listening sessions without frequent recharging. The LED indicators provide clear feedback on connectivity and battery status, enhancing user experience.

In conclusion, the AC International SV01B and V0100 are remarkable audio devices that combine outstanding sound quality, advanced technology, and user-friendly features. They cater to both casual listeners and dedicated audiophiles, making them an excellent choice for anyone looking to elevate their audio experience.