Wiring and Connecting the FLEXware Surge Protector

With the FW-SP-250 or FW-SP-ACA secured, connect all AC and DC wiring as well as any HUB,

MATE, AUX, and BATTERY TEMP cables.

Install all AC and DC power cables fi rst followed by the surge protector wires in their appropriate locations; each wire is labeled on the shrink-wrapped ends near the DC ring terminals and the AC spade lugs

If the AC cables are already installed, loosen the AC wiring block screws in order to insert the surge protector cables

Each surge protector wire inserts directly on top of any installed power wire with its label facing up. The surge protector spade lugs will sit on top of the AC wires connected to the wiring block. The surge protector ring terminals will sit on top of the FX’s DC lugs

Secure the AC wiring block screws to 22 inch-pounds and the DC cables to fi ve foot-pounds after installing each power cable and surge protector wire

MATE/HUB

Battery Temp

Figure 15: Securely connect the surge protector wires to the FX and connect any power, HUB, MATE, AUX, and/or BATTERY TEMP sensor wiring.

FLEXware Surge Protector Wiring Designations:

DC+

DC-

AC HOT OUT

AC HOT IN

AC NEUTRAL OUT

AC NEUTRAL IN

GROUND

16

Image 17 Contents
Surge Protector Includes Mounting and InstallationContact Information About OutBack Power SystemsDisclaimer Dear OutBack Customer Warranty IntroductionModels Outback FLEXware Surge ProtectorIntroduction FLEXware Surge Protector Specifications Electrical Connections and LED IndicatorsLEDs MountingProcedure Tools Required to Install PurposeRemoving and installing FX M5 hex bolts Underside screw secures FW-SP-ACA to FXRemoving various covers from the FX Remove these Two M5 hex bolts from the FXFW-SP-ACA slides onto the FX Preparing and installing the FW-SP-ACA onto an FXScrews included secure the FW-SP-ACA to an FX FW-SP-ACA slides down FX slotsFW-SP-250 FW-SP-250FW250 to check the placement of wires and components FW-ACA housing Locating pin FW-SP-R Replacement for the FW-SP-ACA or the FW-ACA Procedure FW-SP-R LEDs Figures 12 FW-SP-R and FW-ACA BracketLED label FW-SP-R installed inside the FW-ACASecuring wires to FX DC terminals FW-SP-R Replacement for the FW-SP-250FLEXware Surge Protector Wiring Designations Wiring and Connecting the FLEXware Surge ProtectorSystem can now be powered up FLEXware Surge Protector Limited Warranty Revision System Owner Surge Protector Limited Warranty RegistrationArlington, WA +34 19009 62nd Avenue NE