Outback Power Systems manual FW-SP-R Replacement for the FW-SP-ACA or the FW-ACA, Procedure

Page 13

FW-SP-R (REPLACEMENT) for the FW-SP-ACA or the FW-ACA

An FW-SP-R can replace a damaged surge protector in an FW-SP-ACA or FW-SP-250 or be installed in an FW-ACA when surge protection is desired. The FW-ACA includes a bracket for securing the

FW-SP-R.

Tools Required to Install:

Purpose:

Slotted screwdriver

• Wiring to the AC wiring block

Phillips screwdriver

• Remove and install covers

• 13 mm socket (torque ratchet)

• Securing wires to FX terminals

Utility knife

Removing plastic knockouts

• 4 mm Allen wrench

Removing and installing FX M5 hex bolts

NOTE: Always shut off the AC and DC power to the FX before replacing a damaged board or installing a surge protector.

(1)To install an FW-SP-R inside an FW-SP-ACA, remove the FW-SP-ACA by reversing the installation steps on pages 7-9.

Procedure

Installing an FW-SP-R inside an FW-ACA or an FW-SP-ACA

(2) Remove the FW-ACA plastic cover (secured with two Phillips screws)

(3) Remove the FW- ACA Bracket (secured with one Phillips screw); if a damaged FLEXware Surge Protector is being replaced, remove it by disengaging the locating pin

FW-ACA housing

Locating pin

Figure 11: FW-ACA

12

Image 13
Contents Surge Protector Includes Mounting and InstallationDisclaimer About OutBack Power SystemsContact Information Dear OutBack Customer Warranty IntroductionModels Outback FLEXware Surge ProtectorIntroduction FLEXware Surge Protector Specifications Electrical Connections and LED IndicatorsLEDs MountingProcedure Tools Required to Install PurposeRemoving and installing FX M5 hex bolts Underside screw secures FW-SP-ACA to FXRemoving various covers from the FX Remove these Two M5 hex bolts from the FXFW-SP-ACA slides onto the FX Preparing and installing the FW-SP-ACA onto an FXScrews included secure the FW-SP-ACA to an FX FW-SP-ACA slides down FX slotsFW-SP-250 FW-SP-250FW250 to check the placement of wires and components Procedure FW-SP-R Replacement for the FW-SP-ACA or the FW-ACAFW-ACA housing Locating pin FW-SP-R LEDs Figures 12 FW-SP-R and FW-ACA BracketLED label FW-SP-R installed inside the FW-ACASecuring wires to FX DC terminals FW-SP-R Replacement for the FW-SP-250FLEXware Surge Protector Wiring Designations Wiring and Connecting the FLEXware Surge ProtectorSystem can now be powered up FLEXware Surge Protector Limited Warranty Revision Arlington, WA Surge Protector Limited Warranty RegistrationSystem Owner +34 19009 62nd Avenue NE