This catalog is out of date, see note on page 1
Ordering data | Order No. | |
|
|
|
Options for AS 235 H basic |
| |
cabinet |
| |
| Basic unit |
|
Retrofitting of basic unit to redun- |
| |
dant design: |
| |
Central processor module | 6DS1 | |
EDC memory module | 6DS1 | |
with 4000 Kbyte user RAM |
| |
Backup battery for memory | ||
module |
| |
Interface module for I/O bus 1 | 6DS1 | |
Synchronization module | 6DS1 | |
Comparator/coupler module | 6DS1 | |
Interface module for mini floppy | 6DS1 | |
disk unit |
| |
Alarm logic module | 6DS1 | |
Additionally required for the 4th to |
| |
7th extension unit: |
| |
With redundant design: | 6DS1 | |
2 interface modules for I/O bus 2 | ||
With | 6DS1 | |
1 interface module for I/O bus 2 | ||
|
|
|
| Retrofitting of operation |
|
| channels |
|
Retrofitting to redundant operation |
| |
channel 1 or 2: |
| |
Interface module for operation | 6DS1 | |
channel |
| |
Retrofitting of operation channel 2, |
| |
| ||
Interface module for operation | 6DS1 | |
channel |
|
Automation systems
AS 235 H
|
|
| Options for basic cabinet | ||
|
|
|
|
|
|
| Ordering data |
| Order No. | ||
| Bus connection of further |
|
|
| |
| participant via |
|
|
| |
| Interface module for | 6DS1 |
| ||
| bus |
|
|
|
|
| • Starting from standard configu- |
|
|
| |
| ration 6DS2 |
|
|
|
|
| Connecting cable for local bus |
|
|
| |
| with 1 plug | 0.3 m | 6DS8 |
| |
|
| 0.5 m | 6DS8 |
| |
|
| 1.5 m | 6DS8 |
| |
|
| 5.0 m | 6DS8 |
| |
| • and with |
|
|
| |
| unit: |
|
|
|
|
| Front plug 2) |
| 6DS9 |
| |
Interface module for |
|
| |||
6DS1 |
| ||||
| bus |
|
|
|
|
| • and with redundant basic unit: |
|
|
| |
|
|
|
| ||
| 2 interface modules for | 6DS1 |
| ||
|
|
|
|
| |
| Connecting cable for local bus | 6DS8 |
| ||
| with 2 plugs, 0.5 m |
|
|
|
|
|
|
|
|
| |
| Connection to single remote |
|
|
| |
| bus |
|
|
|
|
| Starting from standard configura- |
|
|
| |
| tion 6DS2 |
|
|
|
|
| With |
|
|
| |
| Interface module for | 6DS1 |
| ||
| bus |
|
|
|
|
| Bus converter UI |
| 6DS4 |
| |
| Connector board AF “Remote | 6DS9 | |||
| bus” |
|
|
|
|
| Connecting cable with 5 plugs 3) | 6DS8 | |||
| to connect |
|
|
| |
| 1 an connection distributor for |
|
|
|
Parts set for operation channel switchover
–1 video relay, complete,
–1 connecting cable,
–1 keyboard distributor,
–1 printer distributor
Retrofitting of operation channel 2, redundant:
2 interface modules for opera- tion channel
6DS1
| |
With redundant basic unit: |
|
as above, plus: |
|
2 interface modules for | 6DS1 |
| |
|
|
Connection to redundant |
|
remote bus |
|
• With standard configurations |
|
6DS2 |
|
Parts set for operation channel |
switchover Extension units
Bus converter UI | 6DS4 |
Connector board AF “Remote | 6DS9 |
bus” |
|
For retrofitting of extension units EE2 and EE3:
Subrack for extension unit With mounting parts and slots for 13 I/O modules
•
•
Accessories for EE2 and EE3:
Cable set for power supply
–For extension unit EE2
–For extension unit EE3
Cable set for I/O bus
–For extension unit EE2
–For extension unit EE3
Cable duct Cover
I/O bus comparator and switchover module
Upgrading set with switched- mode regulator DC 5 V (6DS1
6DS9
6DS9
6DS9
6DS9
6DS1
• With standard configurations |
|
6DS2 |
|
With |
|
Interface module for | 6DS1 |
bus |
|
2 bus converters UI | 6DS4 |
2 connector boards AF “Remote | 6DS9 |
bus” |
|
Connecting cable with 5 plugs | 6DS8 |
to connect |
|
1 and 2 and the connection dis- |
|
tributor for |
|
With redundant basic unit: |
|
as above, plus: |
|
2 interface modules | 6DS1 |
|
|
1)Max. 2 within an AS 235 consisting of basic and extension cabinets; cannot be used in ES 100 K.
2)The cable connector 6DS8
3)2 plugs not used.
Siemens PLT 111 · 1999 | 3/15 |