Siemens AS 235 appendix Connecting cables for 20-m local bus, Connecting cables for remote bus

Page 77
6DS9 201-8FC
￿￿
6DS8 204-8
6DS9 201-8CA￿￿
Order No.
6DS8 201-8
6DS9 200-8AA￿￿
6DS8 205-8

This catalog is out of date, see note on page 1

Bus communication

Connecting cables

Connecting cables for 20-m local bus

￿To connect the interface modules for 20-m local bus to one another and to the bus converter UI. A front plug is required for the last participant on the local bus when using the cable 6DS8 201-8.. .

Ordering data

￿Connecting cable for 20-m local bus

between two interface modules for 20-m local bus, 1 plug

0.3 m MB 1.5 m EC 10 m AD

0.5 m SB 5.0 m SC 15 m ED

0.63 m UB

Front plug

Connecting cable for 20-m local bus

between two interface modules for 20-m local bus and bus con- verter UI, 2 plugs

Connecting cables for remote bus

The following two remote bus cables are recommended:

￿

Ordering data

Order No.

 

 

 

Remote bus cable

 

Standard remote bus cable

V45466-D21-B35 1)

Specify length in plain text

Length ..... m

(max. 4 km)

 

Inhouse remote bus cable

V45466-D17-B135 1)

Specify length in plain text

Length ..... m

(max. 2 km) 2)

 

 

 

 

￿

1)

Order from

 

 

ICP CC VCE

 

 

Kistlerhofstr. 170

 

 

D-81379 Munich

 

 

Tel.+49 (89) 722-22150

 

 

Fax +49 (89) 722-41032

 

 

2) When mixed with the standard remote bus cable, the total length of the

two cables must not exceed 4 km.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.3 m

MB 1.5 m EC 5 m

SC

0.5 m

SB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connecting cable for 20-m local

 

bus

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

between interface modules for

 

20-m local bus and bus convert-

 

ers UI1 and UI2, 3 plugs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.3 m

MB 2.0 m HC 2.7 m LC

 

1.2 m

CC 2.2 m JC 5.0 m SC

 

1.5 m

EC 2.5 m KC

 

 

 

 

 

 

 

 

Connecting cable for 20-m local bus

between interface modules for

20-m local bus N-AS and bus con- verters UI1 and UI2 as well as connection distributor for 20-m local bus, 4 plugs

Connecting cable for 20-m local bus

between interface module for

20-m local bus N-AS and bus con- verters UI1 and UI2 as well as connection distributor for 20-m local bus, 5 plugs

Summary of connecting cables with description: see page 3/34.

6/6

Siemens PLT 111 · 1999

Image 77
Contents Teleperm M Brief description IntroductionFunctions of the AS 235 system ConfiguringGeneral system data System dataTechnical data of automation systems Or user-configured with own System architecture ConfiguringPerformance characteristics Scope of performance TML languageOperation and monitoring Important note Redundancy with AS 235 HRedundancy with the AS 235 H automation system Standard function blocks ConfiguringStandard function blocks Blocks for analog and digital processingData blocks Blocks for signal exchange via CSType Designation Function For modules with Order No Driver blocks for I/O modulesDriver blocks for I/O modules with standardized display Driver blocks for configurable Teleperm ME I/O modulesOrganization blocks Output blocks for printer and process monitorSystem architecture Performance characteristics Summary of system properties Redundancy with AS 235 H Configuring Data blocks Driver blocks for I/O modules Driver blocks for configurable Teleperm ME I/O modules Output blocks for printer and process monitor AS 235 H Connection diagramsAS 235 K ES 100 KGeneral GeneralAS 235 automation system Basic cabinetBasic cabinet Basic unitExtension units Standard I/O devicesBus components Power supply componentsOrdering data Ordering data for basic cabinetAS 235 automation system Basic cabinetOptions for AS 235 basic Cabinet Options for basic cabinet6DS9 002-8BB See page 6/6Extension cabinet Extension cabinetExtension cabinet Options for AS 235 extension CabinetAS 235 H automation system AS 235 HAS 235 H automation system, design 6DS3 305-8BA Example of redundancy with Redundant process I/OsInterface modules for 20-m local bus N-AS AS 235 H automation system Options for AS 235 H basic Cabinet AS 235 H extension cabinet AS 235 H automation Ordering data for extension cabinetSystem Extension cabinet Options for AS 235 H exten Sion cabinetBasic system AS 235 KAS 235 K automation system Basic systemAS 235 K automation system, design Interface module for ES 100 KOrdering data for AS 235 K HousingAS 235 K automation SystemES 100 K extension system ES 100 KES 100 K extension system ES 100 K options Ordering data for ES 100 KES 100 K extension Standard cabinets and accessories Standard cabinets and accessoriesSystem cabinet accessories Standard cabinetsOrdering data for system cabinet accessories Standard cabinet with heat exchanger Configuring values for thermal loadPermissible thermal loading Design Technical dataStandard cabinets IP 20 without heat exchanger 12 Standard cabinet with heat exchanger Standard cabinets IP 54 with heat exchangerProcess connection systems Connections for process signal cablesProcess connection systems Process connection systemsStandard I/O devices to AS 235 / AS 235 K Connection diagramsConnection diagrams for standard I/O devices to AS AS 235 K Connection of personal computer Connection of personal computerConnection of process monitors and parallel monitors Connection of process monitors and parallel monitorsStandard I/O devices to AS 235 H Connection diagrams for standard I/O devices to AS 235 HConnection diagrams Connecting cable Plug Cable Max. cable Order No From Length Summary of connecting cablesProportioning Counter modules Signal modulesFunction modules Summary Configurable I/O modules General technical dataLightning protection with distributed configuration Power supply, earthingModules from other systems Selection criteria for I/O modulesClosed-loop control modules Function modulesFunction modules Closed-loop control modulesAnalog input and output modules Signal modulesSignal modules Binary input and output modules Binary input and output modulesBinary input module, testable, 6DS1 618-8CA Binary output module with 16 relays, 6DS1 605-8BAProportioning and counter modules STRUK-AS 220 EA configuring programProportioning counter module, metering pulse input module Metering pulse input module with 8 channels, 6DS1 607-8ABModules which can be used on the I/O bus Modules which can be used on the I/O bus6DS1 342-1BD With S5KE Explanations for the column RemarksExplanations for the column Release Test mode Mode of operationOperation unit PBT 65 process operation keyboardConfiguring keyboard Configuring unitConfiguring keyboard Mini floppy disk unit Mini floppy disk unitMini floppy disk unit 6DS3 900-8AE Floppy disksBus communication Local range ApplicationApplication Single remote bus DesignRemote range Connection distributor AV Connector board AF Remote busBus converter Ul Redundant remote busApplication Other conditions Connecting cables Bus configurationsBus configurations, examples Connecting cables for remote bus Connecting cablesConnecting cables for 20-m local bus Simatic S5 I/Os ET 100U Expansion unitsCentral controllers Coupling of other systems Interface modules for coupling with other systems, summaryParallel coupling with Simatic S5-115U I/O modules Simatic S5 expansion unitsParallel coupling with S5-115U I/O modules Digital input modules Simatic S5-115U I/O modules appropriate for couplingDigital output modules Digital input/output modulesParallel coupling with Simatic S5-135U/155U I/O modules Parallel coupling with S5-135U/155U I/O modulesSimatic S5-135U/155U I/O modules appropriate for coupling Interface module for Simatic S5 expansion units Interface module for Simatic S5 expansion unitsSerial coupling with Simatic S5/S7 central controllers Simatic S5/S7 central controllersSerial coupling With Simatic S5/S7 central controllers Interface module for Simatic S5/S7 central controllers Interface module for Simatic S5/S7 central controllersSerial coupling with Simatic S5 I/Os Simatic S5 I/Os / ET 100UExi modules ET 100U I/O modules appropriate for couplingInterface module for ET 100U Interface module for ET 100UOrdering of options Ordering of complete systems AS 235 standard configurationOrdering information