I/O modules

Configuring

Modules which can be used on the I/O bus

Designation

 

Order No. of

Release

Re-

 

 

module

 

marks

Analog calculation modules

 

 

 

 

Analog calculation module

 

6DS1 715-8BB

2

 

 

 

 

 

SW:03

 

 

Binary calculation modules

 

 

 

 

Binary calculation module

 

6DS1 717-8AA

8

16)

 

 

 

 

SW:08

 

 

Binary/analog calculation

 

6DS1 717-8RR

1

 

 

module (max. 31 channels)

 

 

SW:3

 

 

Binary extension

 

6DS1 719-8AA

2

15)

 

 

 

 

 

 

 

Analog extension

 

6DS1 720-8AA

= 1

15)

 

Binary extension

 

6DS1 719-8RR

1

 

 

(for 6DS1717-8RR)

 

 

 

 

 

Coupling modules

 

 

 

 

Speed controller

 

6DS1 303-8AA

9

 

 

Field multiplexer FM

 

6DS1 304-8AA

6

1)

 

 

 

 

SW: 2

 

 

 

 

6DS1 304-8BB

1

1)

 

 

 

 

SW: 2

 

 

S5-110 coupling

 

6DS1 310-8AA

8

 

 

 

 

6DS1 310-8AB

8

 

 

S5 coupling, serial

 

6DS1 318-8AB

3

1)

 

 

 

 

SW: 1

 

 

S5 coupling, expansion unit

 

6DS1 321-8AA

4

 

 

S5 coupling, serial

 

6DS1 333-8AB

1

 

 

 

 

 

SW=1

 

 

 

 

 

 

 

 

S7 coupling, serial

 

6DS1 333-8AB

1

22)

 

 

 

 

SW=1

 

 

MODBUS coupling

 

6DS1 333-8AB

1

3)

 

(on request)

 

with M1328-V5

SW=5

 

 

I/O bus remote coupling

 

6DS1 322-8AA

5

1)

12)

AS - I/O bus - ES 100 K

 

 

 

 

 

Coupling of SIPART DR20,

 

6DS1 325-8AA

2

2) 3)

TELEPERM D compact

 

 

 

 

 

controller

 

 

 

 

 

S5 coupling, serial,

 

6DS1 327-8AA

4

 

 

ET100, EU / I/Os, coupling

 

 

 

 

 

module TM-S5

 

 

 

 

 

Serial coupling, 4 channels,

 

6DS1 328-8AA

2

18)

 

hardware without firmware

 

 

 

 

 

TM/EA coupling, I/O bus

 

6DS1 312-8BB

2

10)

 

Coupling of external computer

 

6DS1 202-8AB

5

19)

20)

CS 275 / N-V.24

 

 

 

 

 

CP 581 TM interface modules

 

 

 

 

CP 581 TM communications

6DS1 337-1AD

1

19) 20)

module

with S5KE,

SW: ...

2)

21)

 

 

S5KS

 

 

 

 

 

 

 

CP 581 TM-L2 (DP/FDL)

6DS1 341-1AD

1

19) 20)

 

 

with DP drivers

SW: ...

2)

21)

CP 581 TM-L2 (FMS)

6DS1 341-1BD

1

19) 20)

 

 

with S5KE,

SW: ...

2)

21)

 

 

S5KS

 

 

 

 

 

 

 

CP 581 TM FUZZY

6DS1 342-1BD

1

19) 20)

 

 

with S5KE,

SW: ...

2)

21)

 

 

S5KS

 

 

 

Explanations for the column "Remarks"

1)Earlier release versions not permissible!

2)Special product

3)Not a standard product, no system test carried out

4)Cannot be operated in AS 235 systems with auxiliary driver

5)Application only without interrupt!

6)No application as common alarm module (SF 61)

7)Approved for common alarm modules, the latest product release is required.

8)Note current balance of subrack:

max. 4 A per module, max. 16 A per subrack

9)Combination modules for use in TELEPERM M standard systems and in TELEPERM ME systems. Application in AS 235 extension units only as TELEPERM ME module with slot addressing.

10)AS 235: with release 2,

AS 235 H and AS 235 K: with release 1.

11)With AS 235 H: > 5.

12)Observe cycle time for processing with ES 100 K! (delay resulting from cable lengths)

13)Application in ES 100 K not allowed (timing)

14)Connection of transmitters with two-wire system not permissible with AS 235 K and ES 100 K in AC 230 V! The ripple of the power supply in the AS is too high for these transmitters and the connection sys- tem.

15)Module only functions together with 6DS1 717-8AA

16)Only alarm function

17)Module only functions together with 6DS1 713 or 6DS1 731.

18)Only a hardware module; no function in delivered state. For use with standard drivers, the module firmware is usually adapted to existing drivers.

19)A maximum of two modules of type N-V.24 or CP 581 TM are permis- sible in a system (in basic cabinet and extension cabinet)

20)Application in ES 100 K not allowed (5 V power)

21)Hardware/software releases on request:

Siemens Karlsruhe, Dept. ATD TD 4, D-76181 Karlsruhe

22)S7 coupling with 3964 R / RK 512 procedure, SEND/RECEIVE, no FETCH, SIMATIC S5 analog value format

Explanations for the column "Release"

5 Tested with AS 235 system technology, no imperative release ver- sion. No negative information with earlier releases.

1; 2; Permissible releases

=5 Valid release of a module

6 and remark 1) mean an imperative minimum release (6 in this case), i.e. upgrading is essential at least up to release 6.

 

 

Observe the respective indexed remarks for the individual

 

 

modules.

4/10

Siemens PLT 111 · 1999

￿

 

Image 68
Contents Teleperm M Introduction Brief descriptionConfiguring Functions of the AS 235 systemSystem data General system dataTechnical data of automation systems Or user-configured with own Configuring System architecturePerformance characteristics Scope of performance TML languageOperation and monitoring Important note Redundancy with AS 235 HRedundancy with the AS 235 H automation system Configuring Standard function blocksStandard function blocks Blocks for analog and digital processingBlocks for signal exchange via CS Data blocksDriver blocks for I/O modules Type Designation Function For modules with Order NoDriver blocks for configurable Teleperm ME I/O modules Driver blocks for I/O modules with standardized displayOutput blocks for printer and process monitor Organization blocksSystem architecture Performance characteristics Summary of system properties Redundancy with AS 235 H Configuring Data blocks Driver blocks for I/O modules Driver blocks for configurable Teleperm ME I/O modules Output blocks for printer and process monitor Connection diagrams AS 235 HAS 235 K ES 100 KGeneral GeneralBasic cabinet AS 235 automation systemBasic cabinet Basic unitStandard I/O devices Extension unitsPower supply components Bus componentsOrdering data for basic cabinet Ordering dataAS 235 automation system Basic cabinetOptions for basic cabinet Options for AS 235 basic Cabinet6DS9 002-8BB See page 6/6Extension cabinet Extension cabinetExtension cabinet Options for AS 235 extension CabinetAS 235 H AS 235 H automation systemAS 235 H automation system, design 6DS3 305-8BA Redundant process I/Os Example of redundancy withInterface modules for 20-m local bus N-AS AS 235 H automation system Options for AS 235 H basic Cabinet AS 235 H extension cabinet Ordering data for extension cabinet AS 235 H automationSystem Extension cabinet Options for AS 235 H exten Sion cabinetAS 235 K Basic systemAS 235 K automation system Basic systemInterface module for ES 100 K AS 235 K automation system, designHousing Ordering data for AS 235 KAS 235 K automation SystemES 100 K extension system ES 100 KES 100 K extension system ES 100 K options Ordering data for ES 100 KES 100 K extension Standard cabinets and accessories Standard cabinets and accessoriesSystem cabinet accessories Standard cabinetsOrdering data for system cabinet accessories Standard cabinet with heat exchanger Configuring values for thermal loadPermissible thermal loading Design Technical dataStandard cabinets IP 20 without heat exchanger Standard cabinets IP 54 with heat exchanger 12 Standard cabinet with heat exchangerConnections for process signal cables Process connection systemsProcess connection systems Process connection systemsStandard I/O devices to AS 235 / AS 235 K Connection diagramsConnection diagrams for standard I/O devices to AS AS 235 K Connection of personal computer Connection of personal computerConnection of process monitors and parallel monitors Connection of process monitors and parallel monitorsConnection diagrams for standard I/O devices to AS 235 H Standard I/O devices to AS 235 HConnection diagrams Summary of connecting cables Connecting cable Plug Cable Max. cable Order No From LengthProportioning Counter modules Signal modulesFunction modules Summary General technical data Configurable I/O modulesPower supply, earthing Lightning protection with distributed configurationModules from other systems Selection criteria for I/O modulesFunction modules Closed-loop control modulesFunction modules Closed-loop control modulesAnalog input and output modules Signal modulesSignal modules Binary input and output modules Binary input and output modulesBinary input module, testable, 6DS1 618-8CA Binary output module with 16 relays, 6DS1 605-8BASTRUK-AS 220 EA configuring program Proportioning and counter modulesProportioning counter module, metering pulse input module Metering pulse input module with 8 channels, 6DS1 607-8ABModules which can be used on the I/O bus Modules which can be used on the I/O bus6DS1 342-1BD With S5KE Explanations for the column RemarksExplanations for the column Release Mode of operation Test modeOperation unit PBT 65 process operation keyboardConfiguring keyboard Configuring unitConfiguring keyboard Mini floppy disk unit Mini floppy disk unitMini floppy disk unit 6DS3 900-8AE Floppy disksBus communication Local range ApplicationApplication Single remote bus DesignRemote range Connector board AF Remote bus Connection distributor AVBus converter Ul Redundant remote busApplication Other conditions Connecting cables Bus configurationsBus configurations, examples Connecting cables for remote bus Connecting cablesConnecting cables for 20-m local bus Simatic S5 I/Os ET 100U Expansion unitsCentral controllers Interface modules for coupling with other systems, summary Coupling of other systemsParallel coupling with Simatic S5-115U I/O modules Simatic S5 expansion unitsParallel coupling with S5-115U I/O modules Simatic S5-115U I/O modules appropriate for coupling Digital input modulesDigital output modules Digital input/output modulesParallel coupling with S5-135U/155U I/O modules Parallel coupling with Simatic S5-135U/155U I/O modulesSimatic S5-135U/155U I/O modules appropriate for coupling Interface module for Simatic S5 expansion units Interface module for Simatic S5 expansion unitsSerial coupling with Simatic S5/S7 central controllers Simatic S5/S7 central controllersSerial coupling With Simatic S5/S7 central controllers Interface module for Simatic S5/S7 central controllers Interface module for Simatic S5/S7 central controllersSimatic S5 I/Os / ET 100U Serial coupling with Simatic S5 I/OsET 100U I/O modules appropriate for coupling Exi modulesInterface module for ET 100U Interface module for ET 100UOrdering of options Ordering of complete systems AS 235 standard configurationOrdering information