Siemens AS 235 Simatic S5-115U I/O modules appropriate for coupling, Digital input modules

Page 81

This catalog is out of date, see note on page 1

Coupling with other systems

SIMATIC S5 expansion units

Parallel coupling with S5-115U I/O modules

SIMATIC S5-115U I/O modules appropriate for coupling

Module

Electrical

Number of inputs/outputs

 

Order No.

 

isolation

 

 

 

Digital input modules

 

 

Input voltage

 

 

 

 

 

 

 

 

 

 

Digital input 420-7

No

32 inputs

DC 24 V

6ES5 420-7LA11

Digital input 430-7

Yes

32 inputs

DC 24 V

6ES5 430-7LA12

Digital input 431-7

Yes

16 inputs

AC/DC 24 V, AC/DC 48 V

6ES5 431-7LA11

Digital input 432-7

Yes

16 inputs

AC/DC 48 V, AC/DC 60 V

6ES5 432-7LA11

Digital input 434-4

Yes

32 inputs

DC 5 V, DC 15 V

6ES5 434-4UA12

Digital input 434-7

Yes

8 inputs

DC 24 V

6ES5 434-7LA12

Digital input 435-7

Yes

16 inputs

AC/DC 115 V

6ES5 435-7LA11/-7LB11

Digital input 435-7

Yes

8 inputs

AC/DC 115 V

6ES5 435-7LC11

Digital input 436-7

Yes

16 inputs

AC/DC 230 V

6ES5 436-7LA11/-7LB11

Digital input 436-7

Yes

8 inputs

AC/DC 230 V

6ES5 436-7LC11

Digital output modules

 

 

Power supply,

 

 

 

output current/continuous current

 

 

 

 

 

Digital output 441-7

 

 

 

 

No

32 outputs

DC 24 V, 0.5 A

6ES5 441-7LA12

Digital output 451-7

Yes

32 outputs

DC 24 V, 0.5 A

6ES5 451-7LA12/-7LA21

Digital output 453-7

Yes

16 outputs

DC 24 V/48 V/60 V, 0.5 A

6ES5 453-7LA11

Digital output 454-7LA

Yes

16 outputs

DC 24 V, 2 A

6ES5 454-7LA11

Digital output 454-7LB

Yes

8 outputs

DC 24 V, 2 A

6ES5 454-7LB11

Digital output 455-7

Yes

16 outputs

AC 48 V/115 V, 2 A/group

6ES5 455-7LA11

Digital output 456-7LA

Yes

16 outputs

AC115 V/230 V, 1 A

6ES5 456-7LA11

Digital output 456-7LB

Yes

8 outputs

AC115 V/230 V, 2 A

6ES5 456-7LB11

Digital output 457-7

Yes

32 outputs (mechanical

DC 5 V/12 V/24 V, 0.1 A

6ES5 457-7LA11

 

 

switch)

 

 

Digital output 458-7LA

Yes

16 relay contact outputs

AC/DC 30 V, 0.5 A

6ES5 458-7LA11

Digital output 458-7LB

Yes

8 relay contact outputs

AC 250 V, max. 5 A / DC 30 V, max. 2.5 A

6ES5 458-7LB11

Digital output 458-7LC

Yes

16 relay contact outputs

AC 250 V, max. 5 A / DC 30 V, max. 5 A

6ES5 458-7LC11

Digital input/output modules

 

Power supply,

 

 

output current

 

 

 

 

 

Digital input/output 482-7

 

 

 

 

Yes

16 inputs

DC 24 V

6ES5 482-7LA11

 

 

16 outputs

DC 24 V, 0.5 A

 

Digital input/output 482-7

Yes

8 inputs

DC 24 V

6ES5 482-7LF31

 

 

8 outputs

DC 24 V, 2.5 A

 

Analog input modules

 

 

Input ranges

 

 

 

 

 

Analog input 460-7

 

 

 

 

Yes

8 inputs

Signal range corresponding to

6ES5 460-7LA13

 

 

 

measuring range module

 

Analog input 465-7

No

16 inputs (8 with Pt 100)

Signal range corresponding to

6ES5 465-7LA13

 

 

 

measuring range module

 

Analog input 463-4

Yes

4 inputs

0 to 1 V, 0 to 10 V,

6ES5 463-4UA12/-4UB12

 

 

 

0 to 20 mA, 4 to 20 mA

 

Analog input 466-3

Yes

16 single/

3 current ranges up to ± 20 mA

6ES5 466-3LA11

 

 

8 differential inputs

9 voltage ranges up to ±10 V

 

Analog output modules

 

 

Output ranges

 

 

 

 

 

Analog output 470-7LA

 

 

 

 

Yes

8 outputs

± 10 V, 0 to 20 mA

6ES5 470-7LA13

Analog output 470-7LB

Yes

8 outputs

± 10 V

6ES5 470-7LB13

Analog output 470-7LC

Yes

8 outputs

4 to 20 mA, +1 to +5 V

6ES5 470-7LC13

 

 

 

 

 

Details on these I/O modules can be found in Catalog ST 50.

7/4

Siemens PLT 111 · 1999

Image 81
Contents Teleperm M Brief description IntroductionFunctions of the AS 235 system ConfiguringGeneral system data System dataTechnical data of automation systems Or user-configured with own System architecture ConfiguringPerformance characteristics TML language Operation and monitoringScope of performance Redundancy with AS 235 H Redundancy with the AS 235 H automation systemImportant note Standard function blocks ConfiguringStandard function blocks Blocks for analog and digital processingData blocks Blocks for signal exchange via CSType Designation Function For modules with Order No Driver blocks for I/O modulesDriver blocks for I/O modules with standardized display Driver blocks for configurable Teleperm ME I/O modulesOrganization blocks Output blocks for printer and process monitorSystem architecture Performance characteristics Summary of system properties Redundancy with AS 235 H Configuring Data blocks Driver blocks for I/O modules Driver blocks for configurable Teleperm ME I/O modules Output blocks for printer and process monitor AS 235 H Connection diagramsAS 235 K ES 100 KGeneral GeneralAS 235 automation system Basic cabinetBasic cabinet Basic unitExtension units Standard I/O devicesBus components Power supply componentsOrdering data Ordering data for basic cabinetAS 235 automation system Basic cabinetOptions for AS 235 basic Cabinet Options for basic cabinet6DS9 002-8BB See page 6/6Extension cabinet Extension cabinetExtension cabinet Options for AS 235 extension CabinetAS 235 H automation system AS 235 HAS 235 H automation system, design 6DS3 305-8BA Example of redundancy with Redundant process I/OsInterface modules for 20-m local bus N-AS AS 235 H automation system Options for AS 235 H basic Cabinet AS 235 H extension cabinet AS 235 H automation Ordering data for extension cabinetSystem Extension cabinet Options for AS 235 H exten Sion cabinetBasic system AS 235 KAS 235 K automation system Basic systemAS 235 K automation system, design Interface module for ES 100 KOrdering data for AS 235 K HousingAS 235 K automation SystemES 100 K ES 100 K extension systemES 100 K extension system Ordering data for ES 100 K ES 100 K extensionES 100 K options Standard cabinets and accessories Standard cabinets and accessoriesSystem cabinet accessories Standard cabinetsOrdering data for system cabinet accessories Configuring values for thermal load Permissible thermal loadingStandard cabinet with heat exchanger Technical data Standard cabinets IP 20 without heat exchangerDesign 12 Standard cabinet with heat exchanger Standard cabinets IP 54 with heat exchangerProcess connection systems Connections for process signal cablesProcess connection systems Process connection systemsConnection diagrams Connection diagrams for standard I/O devices to AS AS 235 KStandard I/O devices to AS 235 / AS 235 K Connection of personal computer Connection of personal computerConnection of process monitors and parallel monitors Connection of process monitors and parallel monitorsStandard I/O devices to AS 235 H Connection diagrams for standard I/O devices to AS 235 HConnection diagrams Connecting cable Plug Cable Max. cable Order No From Length Summary of connecting cablesSignal modules Function modulesProportioning Counter modules Summary Configurable I/O modules General technical dataLightning protection with distributed configuration Power supply, earthingModules from other systems Selection criteria for I/O modulesClosed-loop control modules Function modulesFunction modules Closed-loop control modulesSignal modules Signal modulesAnalog input and output modules Binary input and output modules Binary input and output modulesBinary input module, testable, 6DS1 618-8CA Binary output module with 16 relays, 6DS1 605-8BAProportioning and counter modules STRUK-AS 220 EA configuring programProportioning counter module, metering pulse input module Metering pulse input module with 8 channels, 6DS1 607-8ABModules which can be used on the I/O bus Modules which can be used on the I/O busExplanations for the column Remarks Explanations for the column Release6DS1 342-1BD With S5KE Test mode Mode of operationOperation unit PBT 65 process operation keyboardConfiguring unit Configuring keyboardConfiguring keyboard Mini floppy disk unit Mini floppy disk unitMini floppy disk unit 6DS3 900-8AE Floppy disksBus communication Application ApplicationLocal range Design Remote rangeSingle remote bus Connection distributor AV Connector board AF Remote busBus converter Ul Redundant remote busBus configurations Bus configurations, examplesApplication Other conditions Connecting cables Connecting cables Connecting cables for 20-m local busConnecting cables for remote bus Expansion units Central controllersSimatic S5 I/Os ET 100U Coupling of other systems Interface modules for coupling with other systems, summarySimatic S5 expansion units Parallel coupling with S5-115U I/O modulesParallel coupling with Simatic S5-115U I/O modules Digital input modules Simatic S5-115U I/O modules appropriate for couplingDigital output modules Digital input/output modulesParallel coupling with Simatic S5-135U/155U I/O modules Parallel coupling with S5-135U/155U I/O modulesSimatic S5-135U/155U I/O modules appropriate for coupling Interface module for Simatic S5 expansion units Interface module for Simatic S5 expansion unitsSimatic S5/S7 central controllers Serial coupling With Simatic S5/S7 central controllersSerial coupling with Simatic S5/S7 central controllers Interface module for Simatic S5/S7 central controllers Interface module for Simatic S5/S7 central controllersSerial coupling with Simatic S5 I/Os Simatic S5 I/Os / ET 100UExi modules ET 100U I/O modules appropriate for couplingInterface module for ET 100U Interface module for ET 100UOrdering of complete systems AS 235 standard configuration Ordering informationOrdering of options