Siemens AS 235 appendix ET 100U I/O modules appropriate for coupling, Exi modules

Page 88

This catalog is out of date, see note on page 1

 

 

 

 

Coupling with other systems

 

 

 

 

SIMATIC S5 I/Os / ET 100U

 

 

 

 

Serial coupling with SIMATIC S5 I/Os

ET 100U I/O modules appropriate for coupling

 

 

 

 

 

 

 

 

 

 

 

Module

Electrical

Number of inputs/outputs

 

 

Order No.

 

 

isolation

 

 

 

 

 

Digital input modules

 

 

 

Input voltage

 

 

 

 

 

 

 

 

Digital input 420-8

 

 

 

 

 

 

No

4 inputs

 

DC 24 V

6ES5 420-8MA11

 

Digital input 421-8

No

8 inputs

 

DC 24 V

6ES5 421-8MA12

 

Digital input 422-8

No

16 inputs

 

DC 24 V

6ES5 422-8MA11

 

Digital input 430-8

Yes

4 inputs

 

DC 24 V/60 V

6ES5 430-8MB11

 

Digital input 430-8

Yes

4 inputs

 

AC/DC 115 V, 47 to 63 Hz

6ES5 430-8MC11

 

Digital input 430-8

Yes

4 inputs

 

AC/DC 230 V, 47 to 63 Hz

6ES5 430-8MD11

 

Digital input 431-8

Yes

8 inputs

 

DC 24 V

6ES5 431-8MA11

 

Digital input 431-8

Yes

8 inputs

 

AC/DC 115 V, 47 to 63 Hz

6ES5 431-8MC11

 

Digital input 431-8

Yes

8 inputs

 

AC/DC 230 V, 47 to 63 Hz

6ES5 431-8MD11

 

Digital input 433-8

Yes

8 inputs

 

DC 5 to 24 V

6ES5 433-8MA11

 

Digital output modules

 

 

 

Power supply,

 

 

 

 

 

output current/continuous current

 

 

 

 

 

 

 

 

Digital output 440-8

 

 

 

 

 

 

No

4 outputs

 

DC 24 V, 0.5 A

6ES5 440-8MA12

 

Digital output 440-8

No

4 outputs

 

DC 24 V, 2 A

6ES5 440-8MA22

 

Digital output 441-8

No

8 outputs

 

DC 24 V, 0.5 A

6ES5 441-8MA11

 

Digital output 450-8

Yes

4 outputs

 

DC 24 V/60 V; 0.5 A

6ES5 450-8MB11

 

Digital output 450-8

Yes

4 outputs

 

AC115 V/230 V;1 A

6ES5 450-8MD11

 

Digital output 451-8

Yes

8 outputs

 

AC115 V/230 V;0.5 A

6ES5 451-8MD11

 

Digital output 451-8

Yes

8 outputs

 

DC 24 V, 1 A

6ES5 451-8MA11

 

Digital output 451-8

Yes

8 relay outputs

 

Max. 3 A with AC 250 V,

6ES5 451-8MR12

 

 

 

 

 

Max. 1.5 A with DC 30 V

 

 

Digital output 452-8

Yes

8 relay outputs

 

Max. 5 A with AC 250 V,

6ES5 452-8MR11

 

 

 

 

 

Max. 2.5 A with DC 30 V

 

 

Digital output 453-8

Yes

8 outputs

 

DC 5 to 24 V; 0.1 A

6ES5 453-8MA11

 

Ex(i) modules

 

 

 

Input voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital input 437-8E

Yes

4 inputs

 

DC 8.2 V 1)

6ES5 437-8EA12

 

Digital output 457-8E

Yes

4 outputs

 

DC 7 V, 2 mA 1)

6ES5 457-8EA12

 

Analog input 467-8E

 

 

 

 

 

 

Yes

1 or 2 inputs, switchable, for 4

 

 

6ES5 467-8EE11

 

 

 

to 20 mA

 

 

 

 

Analog input 467-8E

Yes

4 inputs for thermocouples

 

 

6ES5 467-8EA11

 

Analog input 467-8E

Yes

2 inputs for Pt 100 resistance

 

 

6ES5 467-8EF11

 

 

 

thermometers

 

 

 

 

Analog output 477-8E

Yes

2 outputs for 4 to 20 mA

 

 

6ES5 477-8EC11

 

Analog input modules

 

 

 

 

 

 

 

 

 

 

 

 

 

Analog input 464-8

Yes

4 inputs for ± 50 mV

 

 

6ES5464-8MA11

 

 

Yes

4 inputs for thermocouples

 

 

6ES5 464-8MA21

 

 

 

(± 50 mV), with linearization

 

 

 

 

 

Yes

4 inputs for ± 1 V

 

 

6ES5 464-8MB11

 

 

Yes

4 inputs for ± 10 V

 

 

6ES5 464-8MC11

 

 

Yes

4 inputs for ± 20 mA

 

 

6ES5 464-8MD11

 

 

Yes

4 inputs for 4 to 20 mA

 

 

6ES5 464-8ME11

 

 

Yes

2 inputs for ± 500 mV or Pt 100

 

 

6ES5 464-8MF11

 

 

Yes

2 inputs for ± 500 mV or Pt 100,

 

 

6ES5 464-8MF21

 

 

 

with linearization

 

 

 

 

 

 

 

 

 

 

 

Analog input 466-8

No

4 inputs 0 to 10 V

 

 

6ES5 466-8MC11

 

Analog output modules

 

 

 

 

 

 

 

 

 

 

 

 

 

Analog output 470-8

Yes

2 outputs for ±10 V

 

 

6ES5 470-8MA12

 

 

Yes

2 outputs for ± 20 mA

 

 

6ES5 470-8MB12

 

 

Yes

2 outputs for 4 to 20 mA

 

 

6ES5 470-8MC12

 

 

Yes

2 outputs for 1 to 5 V

 

 

6ES5 470-8MD12

 

 

 

 

 

 

 

 

1) From internal power supply

Details on these I/O modules can be found in Catalog ST 50.

Siemens PLT 111 · 1999

7/11

Image 88
Contents Teleperm M Introduction Brief descriptionConfiguring Functions of the AS 235 systemSystem data General system dataTechnical data of automation systems Or user-configured with own Configuring System architecturePerformance characteristics Operation and monitoring TML languageScope of performance Redundancy with the AS 235 H automation system Redundancy with AS 235 HImportant note Configuring Standard function blocksStandard function blocks Blocks for analog and digital processingBlocks for signal exchange via CS Data blocksDriver blocks for I/O modules Type Designation Function For modules with Order NoDriver blocks for configurable Teleperm ME I/O modules Driver blocks for I/O modules with standardized displayOutput blocks for printer and process monitor Organization blocksSystem architecture Performance characteristics Summary of system properties Redundancy with AS 235 H Configuring Data blocks Driver blocks for I/O modules Driver blocks for configurable Teleperm ME I/O modules Output blocks for printer and process monitor Connection diagrams AS 235 HAS 235 K ES 100 KGeneral GeneralBasic cabinet AS 235 automation systemBasic cabinet Basic unitStandard I/O devices Extension unitsPower supply components Bus componentsOrdering data for basic cabinet Ordering dataAS 235 automation system Basic cabinetOptions for basic cabinet Options for AS 235 basic Cabinet6DS9 002-8BB See page 6/6Extension cabinet Extension cabinetExtension cabinet Options for AS 235 extension CabinetAS 235 H AS 235 H automation systemAS 235 H automation system, design 6DS3 305-8BA Redundant process I/Os Example of redundancy withInterface modules for 20-m local bus N-AS AS 235 H automation system Options for AS 235 H basic Cabinet AS 235 H extension cabinet Ordering data for extension cabinet AS 235 H automationSystem Extension cabinet Options for AS 235 H exten Sion cabinetAS 235 K Basic systemAS 235 K automation system Basic systemInterface module for ES 100 K AS 235 K automation system, designHousing Ordering data for AS 235 KAS 235 K automation SystemES 100 K extension system ES 100 KES 100 K extension system ES 100 K extension Ordering data for ES 100 KES 100 K options Standard cabinets and accessories Standard cabinets and accessoriesSystem cabinet accessories Standard cabinetsOrdering data for system cabinet accessories Permissible thermal loading Configuring values for thermal loadStandard cabinet with heat exchanger Standard cabinets IP 20 without heat exchanger Technical dataDesign Standard cabinets IP 54 with heat exchanger 12 Standard cabinet with heat exchangerConnections for process signal cables Process connection systemsProcess connection systems Process connection systemsConnection diagrams for standard I/O devices to AS AS 235 K Connection diagramsStandard I/O devices to AS 235 / AS 235 K Connection of personal computer Connection of personal computerConnection of process monitors and parallel monitors Connection of process monitors and parallel monitorsConnection diagrams for standard I/O devices to AS 235 H Standard I/O devices to AS 235 HConnection diagrams Summary of connecting cables Connecting cable Plug Cable Max. cable Order No From LengthFunction modules Signal modulesProportioning Counter modules Summary General technical data Configurable I/O modulesPower supply, earthing Lightning protection with distributed configurationModules from other systems Selection criteria for I/O modulesFunction modules Closed-loop control modulesFunction modules Closed-loop control modulesSignal modules Signal modulesAnalog input and output modules Binary input and output modules Binary input and output modulesBinary input module, testable, 6DS1 618-8CA Binary output module with 16 relays, 6DS1 605-8BASTRUK-AS 220 EA configuring program Proportioning and counter modulesProportioning counter module, metering pulse input module Metering pulse input module with 8 channels, 6DS1 607-8ABModules which can be used on the I/O bus Modules which can be used on the I/O busExplanations for the column Release Explanations for the column Remarks6DS1 342-1BD With S5KE Mode of operation Test modeOperation unit PBT 65 process operation keyboardConfiguring keyboard Configuring unitConfiguring keyboard Mini floppy disk unit Mini floppy disk unitMini floppy disk unit 6DS3 900-8AE Floppy disksBus communication Application ApplicationLocal range Remote range DesignSingle remote bus Connector board AF Remote bus Connection distributor AVBus converter Ul Redundant remote busBus configurations, examples Bus configurationsApplication Other conditions Connecting cables Connecting cables for 20-m local bus Connecting cablesConnecting cables for remote bus Central controllers Expansion unitsSimatic S5 I/Os ET 100U Interface modules for coupling with other systems, summary Coupling of other systemsParallel coupling with S5-115U I/O modules Simatic S5 expansion unitsParallel coupling with Simatic S5-115U I/O modules Simatic S5-115U I/O modules appropriate for coupling Digital input modulesDigital output modules Digital input/output modulesParallel coupling with S5-135U/155U I/O modules Parallel coupling with Simatic S5-135U/155U I/O modulesSimatic S5-135U/155U I/O modules appropriate for coupling Interface module for Simatic S5 expansion units Interface module for Simatic S5 expansion unitsSerial coupling With Simatic S5/S7 central controllers Simatic S5/S7 central controllersSerial coupling with Simatic S5/S7 central controllers Interface module for Simatic S5/S7 central controllers Interface module for Simatic S5/S7 central controllersSimatic S5 I/Os / ET 100U Serial coupling with Simatic S5 I/OsET 100U I/O modules appropriate for coupling Exi modulesInterface module for ET 100U Interface module for ET 100UOrdering information Ordering of complete systems AS 235 standard configurationOrdering of options