Siemens AS 235 appendix Power supply components, Bus components

Page 29

This catalog is out of date, see note on page 1

When ordering the extension units it is possible to select whether the extension unit EE1 is to be delivered on its own, together with EE2, or together with EE2 and EE3. The following components are supplied:

• 1, 2 or 3 subracks

 

with slots for 14 I/O modules each

 

– For wire-wrap system

6DS9 002-8BB

– For Maxi-Termi-Point system

6DS9 002-8BA

• 1, 2 or 3 cable ducts, 2 U high

6DS9 906-8AB

• 1, 2 or 3 covers, 2 U high

6DS9 906-8BB

• Cable set for power supply

 

– For EE1 on its own

6DS9 908-8CA

– For EE1 (combined with further EE)

6DS9 908-8CB

– For EE2

6DS9 908-8CC

– For EE3

6DS9 908-8CD

• Cable set for I/O bus, + 5 V, 0 V

 

– With EE1 on its own

6DS9 911-8FA

– With EE1 and EE2

6DS9 911-8FB

– With EE1, EE2 and EE3

6DS9 911-8FC

The extension units are supplied directly with DC 24 V from the power distribution subrack. Each extension unit is fused sepa- rately with 16 A on the power distribution subrack. The DC 5 V supply for the I/O bus is taken from the power supply module SV2 (C79451-Z1359-U9) in the basic unit and applied via the cable set 6DS9 911-8.. .

In addition to the I/O modules, max. 2 interface modules for 20-m local bus N-V.24 can be inserted into the I/O slots of the AS 235 system.

Accessories for the extension units: see Ordering data “Further options for AS 235 basic cabinet”.

I/O modules

The I/O modules are the process interface of the AS 235 auto- mation system. They comprise signal modules and function modules, including calculation modules. See Section 4 for the properties, functions and Ordering data of the I/O modules.

The basic unit of the AS 235 system has 6 slots for I/O modules. A further 42 I/O modules can be accommodated in the basic cabinet by inserting into 3 extension units with 14 slots each. A further 42 I/O modules can be inserted into an additional extension cabinet with up to 3 extension units, thus enabling a total of 90 I/O modules per AS 235 system.

One ES 100 K extension system can additionally be connected per I/O bus.

During planning it should be noted that the 16 A with which each extension unit is fused must not be exceeded.

The I/O modules can be supplied coded, inserted and with labelled slots. Arrangement, designation and connection dia- grams (including address data) are required from the orderer.

• Coding, inserting and labelling

6DS5 705-8AA

for 1 I/O module

 

Power supply components

The standard DC 24 V power supply unit of the AS 235 system comprises:

• Power distribution subrack for DC 24 V

6DS4 407-8CA

with slots for 2 bus converters UI,

 

8 automatic circuit-breakers,

 

1 supply diode, terminal and alarm strip,

 

overvoltage protection

 

• Connection distributor for 20-m local bus

6DS9 207-8AA

• Flashing pulse generator

6DS1 922-8AA

• 3 cabinet power supply terminals

C79165-A3012-D73

Automation systems

AS 235

Basic cabinet

Combination of alarms as well as triggering of cabinet lamps and the cabinet row lamp (AS 235 H)

Combination of cabinet lamps for the basic unit

Generation of a flashing pulse for I/O modules of the TELEPERM ME process control system

Supply of an external minutes pulse

Connection distributor for 20-m local bus (e.g. for central con- figuring with PROGRAF AS+).

The DC 24 V supply is not redundant as standard. However, the power distribution subrack is prepared for a redundant supply of DC 24 V. A redundant supply of DC 24 V into the cabinet is also possible by installing a second supply diode and an extension set consisting of capacitor, a cable set and 2 cabinet supply ter- minals. These must be ordered separately.

The flashing pulse generator has 3 functions:

Generation of a flashing signal which is required by the I/O modules of the TELEPERM ME process control system for alarm display (see Section 4 for modules)

Signal lamp test using the LT key on the front panel (wiring optional)

Electrical isolation of external time synchronization signals. The AS 235 can be synchronized using a minutes pulse.

Bus components

The TELEPERM M systems can communicate with one another via the CS 275 plant bus up to distances of 20 m (local bus) or 4 km (remote bus).

The local bus is redundant as standard. The remote bus can be redundant as an option.

Up to 9 participants can be interconnected as a local bus island via the 20-m local bus (each bus converter Ul counts as 1 par- ticipant). The total length of the connecting cables must not exceed 20 m.

Interface modules for 20-m local bus (e.g. N-AS and N-V.24) of local bus participants can be connected together at the front using cables 6DS8 201-8.. . These cables are only provided with a plug at one end. They must be connected 1:1 at the free end to the plug of the adjacent local bus participant. If a cable is not yet connected there, a front plug 6DS9 200-8AA is required in addition. The cable 6DS8 205-8.. with 2 plugs can be used as an alternative to the combination of cable 6DS8 201-8.. and front plug.

It is possible to connect a personal computer via the connection distributor for 20-m local bus in the power distribution subrack. It must first be integrated into the local bus via a cable connector 6DS8 201-8.. or, in the case of a remote bus connection, via a cable 6DS8 204-8LC / 6DS9 201-8CA (see connection unit). Central configuring and feedback documentation of the AS 235 can be carried out in conjunction with the PROGRAF AS+ engi- neering tool (cf. Section 2).

The AS 235 is connected to a single remote bus via the interface connection unit.

The AS 235 can also be operated on a redundant remote bus. 2 bus converters UI and 2 remote bus connector boards AF are installed in this case. The interface connection unit for redundant remote bus is required for the connection to a redundant remote bus.

The power distribution subrack has separate automatic circuit- breakers for the basic unit and up to 6 extension units in the basic cabinet and the extension cabinets. The major functions of the power distribution subrack are:

Supply of DC 24 V to a cabinet or a cabinet group

Fusing of L+ and PM for the extension units and 24-V heat exchanger

Separate supply of 2 bus converters with DC 24 V

Siemens PLT 111 · 1999

3/5

Image 29
Contents Teleperm M Brief description IntroductionFunctions of the AS 235 system ConfiguringGeneral system data System dataTechnical data of automation systems Or user-configured with own System architecture ConfiguringPerformance characteristics Scope of performance TML languageOperation and monitoring Important note Redundancy with AS 235 HRedundancy with the AS 235 H automation system Standard function blocks ConfiguringStandard function blocks Blocks for analog and digital processingData blocks Blocks for signal exchange via CSType Designation Function For modules with Order No Driver blocks for I/O modulesDriver blocks for I/O modules with standardized display Driver blocks for configurable Teleperm ME I/O modulesOrganization blocks Output blocks for printer and process monitorSystem architecture Performance characteristics Summary of system properties Redundancy with AS 235 H Configuring Data blocks Driver blocks for I/O modules Driver blocks for configurable Teleperm ME I/O modules Output blocks for printer and process monitor AS 235 H Connection diagramsAS 235 K ES 100 KGeneral GeneralAS 235 automation system Basic cabinetBasic cabinet Basic unitExtension units Standard I/O devicesBus components Power supply componentsOrdering data Ordering data for basic cabinetAS 235 automation system Basic cabinetOptions for AS 235 basic Cabinet Options for basic cabinet6DS9 002-8BB See page 6/6Extension cabinet Extension cabinetExtension cabinet Options for AS 235 extension CabinetAS 235 H automation system AS 235 HAS 235 H automation system, design 6DS3 305-8BA Example of redundancy with Redundant process I/OsInterface modules for 20-m local bus N-AS AS 235 H automation system Options for AS 235 H basic Cabinet AS 235 H extension cabinet AS 235 H automation Ordering data for extension cabinetSystem Extension cabinet Options for AS 235 H exten Sion cabinetBasic system AS 235 KAS 235 K automation system Basic systemAS 235 K automation system, design Interface module for ES 100 KOrdering data for AS 235 K HousingAS 235 K automation SystemES 100 K extension system ES 100 KES 100 K extension system ES 100 K options Ordering data for ES 100 KES 100 K extension Standard cabinets and accessories Standard cabinets and accessoriesSystem cabinet accessories Standard cabinetsOrdering data for system cabinet accessories Standard cabinet with heat exchanger Configuring values for thermal loadPermissible thermal loading Design Technical dataStandard cabinets IP 20 without heat exchanger 12 Standard cabinet with heat exchanger Standard cabinets IP 54 with heat exchangerProcess connection systems Connections for process signal cablesProcess connection systems Process connection systemsStandard I/O devices to AS 235 / AS 235 K Connection diagramsConnection diagrams for standard I/O devices to AS AS 235 K Connection of personal computer Connection of personal computerConnection of process monitors and parallel monitors Connection of process monitors and parallel monitorsStandard I/O devices to AS 235 H Connection diagrams for standard I/O devices to AS 235 HConnection diagrams Connecting cable Plug Cable Max. cable Order No From Length Summary of connecting cablesProportioning Counter modules Signal modulesFunction modules Summary Configurable I/O modules General technical dataLightning protection with distributed configuration Power supply, earthingModules from other systems Selection criteria for I/O modulesClosed-loop control modules Function modulesFunction modules Closed-loop control modulesAnalog input and output modules Signal modulesSignal modules Binary input and output modules Binary input and output modulesBinary input module, testable, 6DS1 618-8CA Binary output module with 16 relays, 6DS1 605-8BAProportioning and counter modules STRUK-AS 220 EA configuring programProportioning counter module, metering pulse input module Metering pulse input module with 8 channels, 6DS1 607-8ABModules which can be used on the I/O bus Modules which can be used on the I/O bus6DS1 342-1BD With S5KE Explanations for the column RemarksExplanations for the column Release Test mode Mode of operationOperation unit PBT 65 process operation keyboardConfiguring keyboard Configuring unitConfiguring keyboard Mini floppy disk unit Mini floppy disk unitMini floppy disk unit 6DS3 900-8AE Floppy disksBus communication Local range ApplicationApplication Single remote bus DesignRemote range Connection distributor AV Connector board AF Remote busBus converter Ul Redundant remote busApplication Other conditions Connecting cables Bus configurationsBus configurations, examples Connecting cables for remote bus Connecting cablesConnecting cables for 20-m local bus Simatic S5 I/Os ET 100U Expansion unitsCentral controllers Coupling of other systems Interface modules for coupling with other systems, summaryParallel coupling with Simatic S5-115U I/O modules Simatic S5 expansion unitsParallel coupling with S5-115U I/O modules Digital input modules Simatic S5-115U I/O modules appropriate for couplingDigital output modules Digital input/output modulesParallel coupling with Simatic S5-135U/155U I/O modules Parallel coupling with S5-135U/155U I/O modulesSimatic S5-135U/155U I/O modules appropriate for coupling Interface module for Simatic S5 expansion units Interface module for Simatic S5 expansion unitsSerial coupling with Simatic S5/S7 central controllers Simatic S5/S7 central controllersSerial coupling With Simatic S5/S7 central controllers Interface module for Simatic S5/S7 central controllers Interface module for Simatic S5/S7 central controllersSerial coupling with Simatic S5 I/Os Simatic S5 I/Os / ET 100UExi modules ET 100U I/O modules appropriate for couplingInterface module for ET 100U Interface module for ET 100UOrdering of options Ordering of complete systems AS 235 standard configurationOrdering information