ISA Configuration Utility Messages: Dell OptiPlex GX1
Back to Contents Page
ISA Configuration Utility Messages: Dell™ OptiPlex™ GX1 Low- Profile Managed PC Systems
Overview | Configuration Manager Messages |
ICU Error Messages
Overview
The ISA Configuration Utility (ICU) and its Configuration Manager are capable of identifying problems and alerting you to them. Both utilities can alert you to problems with card configuration and problems that prevent proper operation of the utility. This appendix describes each type of message and lists the possible causes and actions you can take to resolve problems indicated by a message. See the following tables to locate your message and identify possible corrective actions.
ICU Error Messages
The ICU displays a variety of error messages while in operation. These messages alert you to problems that prevent the ICU from running correctly and inform you of resource conflicts that prevent the configuration of various cards in your computer. If you receive a message from the ICU, see the following table for suggestions on resolving problems indicated by the message.
Message | Probable Cause | Corrective Action |
Out of memory | Either of these |
| messages can appear if |
Memory allocation failed | the system runs out of |
| memory during |
| operation of the utility. |
Disable any TSR programs or any unneeded device drivers.
Not enough memory to run the ICU
This message appears when you start the ICU if the system does not have enough memory to run the utility.
Disable any TSR programs or any unneeded device drivers.
Can't open index file. This file is required for ICU to run.
No Configuration Manager.
The ICU cannot find the index file for its database.
The device driver needed by the ICU is corrupted or is not correctly configured.
Make sure to switch to drive A before attempting to start the utility.
Verify that the following device statement appears in your config.sys file:
device=drive:\directory\