Dell 7010 Error Message Description, Memory Modules and, if necessary, replace them, Problem

Page 51

Error Message

Description

Decreasing available

One or more memory modules may be faulty or improperly seated. Re-install the memory

memory

modules and, if necessary, replace them.

Diskette drive 0 seek

A cable may be loose or the computer configuration information may not match the hardware

failure

configuration.

Diskette read failure

The floppy disk may be defective or a cable may be loose. If the drive access light turns on, try

 

a different disk.

Diskette subsystem

The floppy drive controller may be faulty.

reset failed

 

Gate A20 failure

One or more memory modules may be faulty or improperly seated. Reinstall the memory

 

modules and, if necessary, replace them.

General failure

The operating system is unable to carry out the command. This message is usually followed by

 

specific information—for example, Printer out of paper. Take the appropriate action to resolve

 

the problem.

Hard-disk drive

The hard drive failed initialization.

configuration error

 

Hard-disk drive

The hard drive failed initialization.

controller failure

 

Hard-disk drive

The hard drive failed initialization.

failure

 

Hard-disk drive read

The hard drive failed initialization.

failure

 

Invalid configuration

The computer configuration information does not match the hardware configuration.

information-please

 

run SETUP program

 

Invalid Memory

DIMM1 slot does not recognize a memory module. The module should be re-seated or

configuration, please

installed.

populate DIMM1

 

Keyboard failure

A cable or connector may be loose, or the keyboard or keyboard/mouse controller may be

 

faulty.

Memory address line

A memory module may be faulty or improperly seated. Reinstall the memory modules and, if

failure at address,

necessary, replace them.

read value expecting

 

value

 

Memory allocation

The software you are attempting to run is conflicting with the operating system, another

error

program, or a utility.

Memory data line

A memory module may be faulty or improperly seated. Reinstall the memory modules and, if

failure at address,

necessary, replace them.

read value expecting

 

value

 

51

Image 51
Contents Regulatory Model D03S Regulatory Type D03S002 Dell Inc Contents Specifications Contacting Dell System SetupDiagnostics Troubleshooting Your ComputerBefore Working Inside Your Computer Working on Your ComputerTurning Off Your Computer After Working Inside Your ComputerClick Shut Down Removing the Cover Removing and Installing ComponentsInstalling the Cover Recommended ToolsRemoving the Front Bezel Installing the Front BezelInstalling The Wlan Card Removing The Wireless Local Area Network Wlan CardRemoving the Drive Cage Removing the Optical Drive Installing the Drive CagePage Installing the Optical Drive Removing the Hard DrivePry the sides of the bracket to remove the optical drive Installing the Hard Drive Removing the Intrusion Switch Installing the Intrusion Switch Memory Module GuidelinesRemoving the Memory Removing the Coin-Cell Battery Installing the MemoryInstalling the Coin-Cell Battery Removing the System FanRemove Cover Front bezel Drive cage Page Removing the Speaker Installing the System FanRemoving the Power-Switch Cable Installing the SpeakerRemoving the Input/Output I/O Panel Installing the Power-Switch CableInstalling the Input/Output I/O Panel Removing the Power SupplyRemove Cover Page Page Lift the power supply out of the computer Installing the Power SupplyRemoving the Heat Sink Page Removing the Processor Installing the Heat SinkRemoving the System Board Installing the ProcessorPage Power connector System Board ComponentsProcessor Installing the System Board Page Navigation Keys System SetupBoot Sequence Following table displays the system setup navigation keysSystem Setup Options RAID on Sata is configured to support RAID mode Disabled The Sata controllers are hiddenATA Sata is configured for ATA mode Ahci Sata is configured for Ahci modeOptionDescription Is enabled and visible to the operating system They are set. This option is disabled by defaultPassword Change Permitted when an administrator password is setOption is enabled by default Reset All Keys- Resets to default settingKeys will restore to default settings All Enabled by defaultPower Off default Disabled by defaultAC Recovery Power loss. You can set the AC Recovery toSequence required to enter the Bios Boot Option Menu Signals. For Ultra Small Form Factor onlyIs enabled by default Keyboard ErrorsImageServer IP Software communicates. The default IP address isCommunicate. The default IP port is Serr MessagesClick Drivers & Downloads Updating the BiosJumper Settings System and Setup PasswordComputer Assigning a System Password and Setup PasswordDisabling a System Password Enhanced Pre-Boot System Assessment ePSA Diagnostics DiagnosticsPage Possible system board resource and/or hardware failure Troubleshooting Your ComputerPower LED Diagnostics Amber LED State White LED State DescriptionBeep Code Error MessagesInformation-please Run Setup program Invalid Memory Error Message DescriptionFailure Configuration ProblemValue Memory size Disk errorNot a boot diskette System installed on it. Insert a bootable floppy diskWrite fault Write fault onSelected drive Page Feature Specification SpecificationsFeature SpecificationExpress Chipset CPU-GPU Combo Discrete PCI Express x16 graphics adapterIntegrated Two Channel High Definition Audio Back Panel Audio Front PanelMini-Tower and Desktop One 36-pin connector Form factorPCI Express x1 data width maximum one PCI Express lane Connector Front of the computer Power button lightWhite light indicates sleep state of the computer Physical Height Width Depth Weight Power Wattage Maximum Heat Dissipation Voltage24.00 cm 30 kg 7.28 lb Inches Physical Height Width Depth Weight Ultra Small Form FactorPage Contacting Dell