AMX nxc manual GET Mode, Iroff, Pod, Pof, Pon

Page 24

NXC-IRS4 4-Port IR/S Control Card

NXC-IRS4 Send_Commands (Cont.)

Command

Description

 

 

GET MODE

Poll the IR/Serial port's configuration parameters and report the active mode settings to the device

 

requesting the information.

 

The port responds with: <port #> <mode>,<carrier>,<io link channel>.

 

Syntax:

 

SEND_COMMAND <DEV>,"'GET MODE'"

 

Example:

 

SEND_COMMAND IR_1,"'GET MODE"

 

The system could respond with:

 

PORT 4 IR,CARRIER,IO LINK 0

IROFF

Halt and Clear all active or buffered IR commands being output on the designated port.

 

Syntax:

 

SEND_COMMAND <DEV>,"'IROFF'"

 

Example:

 

SEND_COMMAND IR_1,"'IROFF"

 

Immediately halts and clears all IR output signals on the IR_1 port.

 

 

POD

Disable previously active 'PON' (power on) or 'POF' (power off) command settings. Channel 255

 

changes are enabled. This command is used in conjunction with the I/O Link command.

 

Syntax:

 

SEND_COMMAND <DEV>,"'POD'"

 

Example:

 

SEND_COMMAND IR_1,"'POD"

 

Disables the 'PON' and 'POF' command settings on the IR_1 device.

 

 

POF

Turn OFF a device connected to an IR port based on the status of the corresponding I/O Link input. If

 

at any time the IR sensor input reads that the device is ON (such as if someone turned it on manually

 

at the front panel), IR function 28 (if available) or IR function 9 is automatically generated in an

 

attempt to turn the device back OFF. If three attempts fail, the IR port will continue executing

 

commands in the buffer.

 

If there are no commands in the buffer, the IR port will continue executing commands in the buffer

 

and trying to turn the device OFF until a 'PON' or 'POD' command is received. If the IR port fails to

 

turn the device OFF, a PUSH and RELEASE is made on channel 254 to indicate a power failure

 

error. You can only use the 'PON' and 'POF' commands when an IR device has a linked I/O channel.

 

Channel 255 changes are disabled after receipt of this command. You can only use the PON and

 

POF commands when an IR device has a linked I/O channel.

 

Syntax:

 

SEND_COMMAND <DEV>,"'POF'"

 

Example:

 

SEND_COMMAND IR_1,"'POF'"

 

Sends power down IR commands 28 (if present) or 9 to the IR_1 device.

 

 

PON

Turn ON a device connected to an IR port based on the status of the corresponding I/O Link input. If

 

at any time the IR sensor input reads that the device is OFF (such as if one turned it off manually at

 

the front panel), IR function 27 (if available) or IR function 9 is automatically generated in an attempt

 

to turn the device back ON. If three attempts fail, the IR port will continue executing commands in the

 

buffer and trying to turn the device On.

 

If there are no commands in the buffer, the IR port will continue trying to turn the device ON until a

 

'POF' or 'POD' command is received. If the IR port fails to turn the device ON, a PUSH and

 

RELEASE is made on channel 254 to indicate a power failure error. You can only use the 'PON' and

 

'POF' commands when an IR device has a linked I/O channel. Channel 255 changes are disabled

 

after receipt of this command.

 

Syntax:

 

SEND_COMMAND <DEV>,"'PON'"

 

Example:

 

SEND_COMMAND IR_1,"'PON'"

 

Sends power up IR commands 27 or 9 to the IR_1 port.

 

 

18

NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide

Image 24
Contents NetLinx Cardframe Control Cards NetModules Operation/Reference GuideAMX Limited Warranty and Disclaimer Table of Contents NXC-I/O10 Input/Output Control Card NXC-VOL4 Volume Control Card Page NXF Cardframe Specifications NXF Cardframe SpecificationsNXF CardFrame and NetModules OverviewRear Panel Components +12 VDC PWRPosition NXS-NMS NetModules Specifications NXS-NMS NetModulesNumber PortMounting modules into an equipment rack Specifications NXC-COM2 SpecificationsNXC-COM2 Dual COM Port Control Card DeviceidPinouts and Wiring Configuration NXC-COM2 Channel AssignmentNXC-COM2 Programming Information Chard ChardmCtspsh GET BaudHson RxclrRxoff RxonNXC-COM2 SendString Escape Sequences TxclrXoff XONCommand Description 27,18,0 27,18,127,19,time 27,20,0NXC-I/O10 Specifications NXC-I/O10 Input/Output Control CardPinouts, Signals, and I/O Mode Functions Setting the Switch/Voltage Mode JumpersNXC-I/O10 Pinouts, Signals, and I/O Mode Functions NXC-I/O10 Channel AssignmentsSetting the Voltage Clamp Jumper +12V or Open +12 V mode setting defaultOpen mode setting Page NXC-IRS4 Specifications NXC-IRS4 4-Port IR/S Control CardPinouts, Signals, and Functions NXC-IRS4 Channel AssignmentsProgramming Information Ctof CtonGET Mode IroffPOD POFPtof PtonSET Input Link SET IO LinkSET Mode Mode 1 Example x x x enterXCH XchmCommand Description Xchm Mode 3 Example 100100… xPage NXC-REL10 Specifications NXC-REL10 Relay Control CardPinouts and Functions NXC-REL10 Channel AssignmentsNXC-REL10 Connections/Wiring No Normally openNXC-VAI4 Specifications NXC-VAI4 Analog Voltage Control CardIref NXC-VAI4 Pinouts, Signals, and Functions Channel AssignmentsNXC-VAI4 Channel Assignments Channel State FunctionStops voltage ramping on Output 4 at current value NXC-VAI4 Output Level Assignments NXC-VAI4 Output Level AssignmentsLevel Description NXC-VAI4 SendCommands NXC-VAI4 Input Level AssignmentsNXC-VAI4 Input Level Assignments Levoff LevonCurve RateLevel Value Functions. Negative voltages are not valid for Inputs Page NXC-VOL4 Volume Control Card NXC-VOL4 SpecificationsNXC-VOL4 Connections/Wiring NXC-VOL4 Pinouts, Signals, and FunctionsAudio Channel Gain Ratio Jumper Settings NXC-VOL4 Channel Assignments NXC-VOL4 LevelsNXC-VOL4 Channel Assignments per port NXC-VOL4 LevelsNXC-VOL4 SendCommands SendlevelPage It’s Your World Take Control