AMX nxc manual Functions. Negative voltages are not valid for Inputs

Page 39

 

NXC-VAI4 Analog Voltage Control Card

 

NXC-VAI4 Send_Commands (Cont.)

 

 

Command

Description

 

 

PX

Sets the value of "I/O <x> MAXIMUM" which is either the maximum output voltage allowed for an

 

Output, or the maximum position voltage expected for an Input.Voltage settings are rounded to the

 

nearest D/A or A/D code. Voltage settings are absolute levels and are unaffected by any scaling

 

functions. Negative voltages are not valid for Inputs.

 

Syntax:

 

SEND_COMMAND <DEV>,'P<I/O>X<LEVEL VALUE>'

 

Variables:

 

I/O: Any input or output ('1', '2', '3', '4', '5', '6', '7', '8')

 

LEVEL VALUE: 12.000V to +12.000V

 

Examples:

 

SEND_COMMAND <DEV>,'P1X5.023V'

 

Sets the maximum output level for Output 1 to 5.023V.

 

SEND_COMMAND <DEV>,'P7X5.023V'

 

Sets the maximum of the expected input range for Input 7 to 5.023V.

 

 

PZ

Sets one of the two "set point" variables "I/O <x> SET POINT HL" (high or low). These variables are

 

used to calculate calibration parameters for I/O <x> (input or output). Receiving this command with no

 

voltage specified returns the

 

specified set point to the default value.

 

Syntax:

 

SEND_COMMAND <DEV>,'P<I/O>Z<VOLTAGE>HL'

 

Variables:

 

I/O: Any input or output ('1', '2', '3', '4', '5', '6', '7', '8' plus '0' for EREF)

 

VOLTAGE: The current actual/measured voltage at the I/O.

 

Examples:

 

SEND_COMMAND <DEV>,'P1Z0.5VL'

 

Creates a low-end calibration point associating the current D/A code with 0.5 volts.

 

SEND_COMMAND <DEV>,'P1Z11.5VH'

 

Creates a high-end calibration point associating the current D/A code with 11.5 volts.

 

SEND_COMMAND <DEV>,'P0Z0.1VL'

 

Creates a low-end calibration point associating the current EREF A/D code with 0.1 volts.

 

SEND_COMMAND <DEV>,'P1ZL'

 

Returns the Output 1 lower set point to its default.

 

 

NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide

33

 

 

Image 39
Contents Operation/Reference Guide NetLinx Cardframe Control Cards NetModulesAMX Limited Warranty and Disclaimer Table of Contents NXC-I/O10 Input/Output Control Card NXC-VOL4 Volume Control Card Page Overview NXF Cardframe SpecificationsNXF Cardframe Specifications NXF CardFrame and NetModulesRear Panel Components +12 VDC PWRPosition Port NXS-NMS NetModules SpecificationsNXS-NMS NetModules NumberMounting modules into an equipment rack Deviceid SpecificationsNXC-COM2 Specifications NXC-COM2 Dual COM Port Control CardPinouts and Wiring Configuration NXC-COM2 Channel AssignmentNXC-COM2 Programming Information GET Baud ChardChardm CtspshRxon HsonRxclr RxoffXON NXC-COM2 SendString Escape SequencesTxclr Xoff27,20,0 Command Description 27,18,027,18,1 27,19,timeNXC-I/O10 Input/Output Control Card NXC-I/O10 SpecificationsNXC-I/O10 Channel Assignments Pinouts, Signals, and I/O Mode FunctionsSetting the Switch/Voltage Mode Jumpers NXC-I/O10 Pinouts, Signals, and I/O Mode FunctionsSetting the Voltage Clamp Jumper +12V or Open +12 V mode setting defaultOpen mode setting Page NXC-IRS4 4-Port IR/S Control Card NXC-IRS4 SpecificationsPinouts, Signals, and Functions NXC-IRS4 Channel AssignmentsProgramming Information Cton CtofPOF GET ModeIroff PODSET IO Link PtofPton SET Input LinkXchm SET ModeMode 1 Example x x x enter XCHMode 3 Example 100100… x Command Description XchmPage NXC-REL10 Channel Assignments NXC-REL10 SpecificationsNXC-REL10 Relay Control Card Pinouts and FunctionsNo Normally open NXC-REL10 Connections/WiringNXC-VAI4 Specifications NXC-VAI4 Analog Voltage Control CardIref Channel State Function NXC-VAI4 Pinouts, Signals, and FunctionsChannel Assignments NXC-VAI4 Channel AssignmentsStops voltage ramping on Output 4 at current value NXC-VAI4 Output Level Assignments NXC-VAI4 Output Level AssignmentsLevel Description NXC-VAI4 SendCommands NXC-VAI4 Input Level AssignmentsNXC-VAI4 Input Level Assignments Levon LevoffRate CurveLevel Value Functions. Negative voltages are not valid for Inputs Page NXC-VOL4 Specifications NXC-VOL4 Volume Control CardNXC-VOL4 Connections/Wiring NXC-VOL4 Pinouts, Signals, and FunctionsAudio Channel Gain Ratio Jumper Settings NXC-VOL4 Levels NXC-VOL4 Channel AssignmentsNXC-VOL4 Levels NXC-VOL4 Channel Assignments per portSendlevel NXC-VOL4 SendCommandsPage It’s Your World Take Control