AMX nxc manual Ptof, Pton, SET Input Link, SET IO Link

Page 25

NXC-IRS4 4-Port IR/S Control Card

NXC-IRS4 Send_Commands (Cont.)

PTOF

Set the time duration between power pulses in .10-second increments.

 

This time increment is stored in permanent memory. This command also sets the delay between

 

pulses generated by the 'PON' or 'POF' send commands in tenths of seconds. It also sets the delay

 

required after a power ON command before a new IR function can be generated. This gives the

 

device time to power up and get ready for future IR commands. It also sets the delay required after a

 

power ON command before a new IR function can be generated. This gives the device time to power

 

up and get ready for future IR commands.

 

Syntax:

 

SEND_COMMAND <DEV>,"'PTOF',<time>"

 

Variable:

 

time = 0 - 255. Given in 1/10ths of a second. Default is 15 (1.5 seconds).

 

Example:

 

SEND_COMMAND IR_1,"'PTOF',15"

 

Sets the time between power pulses to 1.5 seconds for the IR_1 device.

 

 

PTON

Set the time duration between power pulses in .10-second increments.

 

This time increment is stored in permanent memory. This command also sets the pulse length for

 

each pulse generated by the 'PON' or 'POF' send commands in tenths of seconds.

 

Syntax:

 

SEND_COMMAND <DEV>,"'PTON',<time>"

 

Variable:

 

time = 0 - 255. Given in 1/10ths of a second. Default is 5 (0.5 seconds).

 

Example:

 

SEND_COMMAND IR_1,"'PTON',15"

 

Sets the duration of the power pulse to 1.5 seconds for the IR_1 device.

 

 

SET INPUT LINK

Sets an IR device to link to an input channel for use with 'PON' and 'POF' commands. The input

 

channel is used for power sensing (via a PCS). A channel of zero disables the link.

 

Syntax:

 

SEND_COMMAND <DEV>,"'SET INPUT LINK <channel>'"

 

Variable:

 

channel = 1 - 4. Setting the channel to 0 disables the link.

 

Example:

 

SEND_COMMAND IR_1,"'SET INPUT LINK 1'"

 

Sets the IR_1 port link to I/O channel 1. The IR port uses the specified input as power status for

 

processing PON and POF commands.

 

 

SET IO LINK

Link an IR or Serial port to a selected I/O channel for use with the 'DE', 'POD', 'PON', and 'POF'

 

commands. The I/O status is automatically reported on channel 255 on the IR port. The I/O channel

 

is used for power sensing (via a PCS or VSS). A channel of zero disables the I/O link.

 

Syntax:

 

SEND_COMMAND <DEV>,"'SET IO LINK <I/O number>'"

 

Variable:

 

I/O number = 1 - 4. Setting the I/O channel to 0 disables the I/O link.

 

Example:

 

SEND_COMMAND IR_1,"'SET INPUT LINK 1'"

 

Sets the IR_1 port link to I/O channel 1. The IR port uses the specified input as power status for

 

processing PON and POF commands.

 

Note: This command is included for older programs only. The Input port is not an I/O. No output

 

functions are available.’SET IO LINK’ applies the same configuration as the ’SET INPUT LINK’

 

command.

 

 

NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide

19

 

 

Image 25
Contents Operation/Reference Guide NetLinx Cardframe Control Cards NetModulesAMX Limited Warranty and Disclaimer Table of Contents NXC-I/O10 Input/Output Control Card NXC-VOL4 Volume Control Card Page NXF Cardframe Specifications NXF Cardframe SpecificationsNXF CardFrame and NetModules Overview+12 VDC PWR Rear Panel ComponentsPosition NXS-NMS NetModules NXS-NMS NetModules SpecificationsNumber PortMounting modules into an equipment rack NXC-COM2 Specifications SpecificationsNXC-COM2 Dual COM Port Control Card DeviceidNXC-COM2 Channel Assignment Pinouts and Wiring ConfigurationNXC-COM2 Programming Information Chardm ChardCtspsh GET BaudRxclr HsonRxoff RxonTxclr NXC-COM2 SendString Escape SequencesXoff XON27,18,1 Command Description 27,18,027,19,time 27,20,0NXC-I/O10 Input/Output Control Card NXC-I/O10 SpecificationsSetting the Switch/Voltage Mode Jumpers Pinouts, Signals, and I/O Mode FunctionsNXC-I/O10 Pinouts, Signals, and I/O Mode Functions NXC-I/O10 Channel Assignments+12 V mode setting default Setting the Voltage Clamp Jumper +12V or OpenOpen mode setting Page NXC-IRS4 4-Port IR/S Control Card NXC-IRS4 SpecificationsNXC-IRS4 Channel Assignments Pinouts, Signals, and FunctionsProgramming Information Cton CtofIroff GET ModePOD POFPton PtofSET Input Link SET IO LinkMode 1 Example x x x enter SET ModeXCH XchmMode 3 Example 100100… x Command Description XchmPage NXC-REL10 Relay Control Card NXC-REL10 SpecificationsPinouts and Functions NXC-REL10 Channel AssignmentsNo Normally open NXC-REL10 Connections/WiringNXC-VAI4 Analog Voltage Control Card NXC-VAI4 SpecificationsIref Channel Assignments NXC-VAI4 Pinouts, Signals, and FunctionsNXC-VAI4 Channel Assignments Channel State FunctionStops voltage ramping on Output 4 at current value NXC-VAI4 Output Level Assignments NXC-VAI4 Output Level AssignmentsLevel Description NXC-VAI4 Input Level Assignments NXC-VAI4 SendCommandsNXC-VAI4 Input Level Assignments Levon LevoffRate CurveLevel Value Functions. Negative voltages are not valid for Inputs Page NXC-VOL4 Specifications NXC-VOL4 Volume Control CardNXC-VOL4 Pinouts, Signals, and Functions NXC-VOL4 Connections/WiringAudio Channel Gain Ratio Jumper Settings NXC-VOL4 Levels NXC-VOL4 Channel AssignmentsNXC-VOL4 Channel Assignments per port NXC-VOL4 LevelsSendlevel NXC-VOL4 SendCommandsPage It’s Your World Take Control