NXC-VAI4 Analog Voltage Control Card
The
Each port can be configured for a variety of DC input and output signals.
The
FIG. 7 NXC-VAI4 Analog Voltage Control card
Specifications
NXC-VAI4 Specifications
Power Requirements | 330 mA @ 12 VDC |
|
|
Inputs | Four |
|
|
Outputs | Four analog DC outputs |
|
|
D/A, A/D conversion | A/D and D/A converters for analog sampling and control. 8 or |
| the ADMODE SEND_COMMAND (see theProgramming Information section on |
| page 29 for details) |
|
|
Available input voltages | 0 V to +12 V |
|
|
Available output voltages: |
|
The output voltage may be | |
| 12 and +12 VDC. |
| • Maximum output current = 60 mA per output. |
| • |
External reference |
|
A user supplied external reference voltage can be used to set the maximum voltage | |
| range for the D/A outputs. The full analog output range is scaled to fit the maximum |
| range set by the external reference. |
| Output voltage may be set to any level between |
| reference voltage input and |
External reference input: |
|
• Maximum external reference input voltage = +12 VDC. | |
(EREF - one for each output) | • |
Internal reference output: |
|
• +5 V reference output, maximum current = 60 mA. | |
(IREF) | • This output is intended to drive a |
|
|
NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide | 25 |
|
|