AMX nxc manual Level Value

Page 38

NXC-VAI4 Analog Voltage Control Card

NXC-VAI4 Send_Commands (Cont.)

Command

Description

 

 

PN

Sets the value of either the minimum output voltage allowed for an output, or the minimum position

 

voltage expected for an input. Voltage settings are rounded to the nearest D/A or A/D code. Voltage

 

settings for Outputs are absolute levels and are unaffected by any software scaling functions. Negative

 

voltages are not valid for Input 3.

 

Syntax:

 

SEND_COMMAND <DEV>,'P<I/O>N<LEVEL VALUE>'

 

Variables:

 

I/O: Any input or output ('1','2','3','4','5','6','7','8')

 

LEVEL VALUE: -12.000V to +12.000V

 

Examples:

 

SEND_COMMAND <DEV>,'P1N5.023V'

 

Sets the minimum output level for Output 1 to 5.023V.

 

SEND_COMMAND <DEV>,'P1N-5.023V'

 

Sets the minimum output level for Output 1 to -5.023V.

 

SEND_COMMAND <DEV>,'P7N5.023V'

 

Sets the minimum of the expected input range for Input 7 to 5.023V.

 

 

PR

Sets the CURRENT OUTPUT <x> RAMP UP TIME and/or CURRENT OUTPUT <x> RAMP DOWN

 

TIME of the specified Output where TIME is the time to ramp the full range. It can be set to ramp both

 

down to up and up to down or just down to up or just up to down.

 

Syntax:

 

SEND_COMMAND <DEV>,'P<OUTPUT>R<TIME>[UD]'

 

Variables:

 

OUTPUT: Any Output '1', '2', '3', or '4'

 

TIME: 0 - 255 in 0.1 second increments

 

U/D: Ramp Up (U) or Down (D)

 

Examples:

 

SEND_COMMAND <DEV>,'P1R25'

 

Sets CURRENT OUTPUT 1 RAMP UP TIME" and "CURRENT OUTPUT 1 RAMP DOWN TIME" to

 

2.5 seconds each for full range travel.

 

SEND_COMMAND <DEV>,'P2R75U'

 

Sets CURRENT OUTPUT 2 RAMP UP TIME to 7.5 seconds for full range travel, CURRENT OUTPUT

 

2 RAMP DOWN TIME remains unchanged.

 

SEND_COMMAND <DEV>,'P2R50D'

 

Sets "CURRENT OUTPUT 2 RAMP DOWN TIME" to 5 seconds for full range travel; "CURRENT

 

OUTPUT 2 RAMP UP TIME" remains unchanged.

 

 

PU

Sets the level to which this Output is set immediately after power-up and before any Output is

 

commanded.

 

Syntax:

 

SEND_COMMAND <DEV>,'P<OUTPUT>U<LEVEL VALUE>'

 

Variables:

 

OUTPUT: Any Output ('1', '2', '3', or '4')

 

LEVEL VALUE: 0-255

 

Example:

 

SEND_COMMAND <DEV>,'P1U127'

 

Sets the power up output level for Output 1 to 127.

 

 

32

NetLinx Cardframe, Control Cards, and NetModules - Operation Reference Guide

Image 38
Contents NetLinx Cardframe Control Cards NetModules Operation/Reference GuideAMX Limited Warranty and Disclaimer Table of Contents NXC-I/O10 Input/Output Control Card NXC-VOL4 Volume Control Card Page NXF CardFrame and NetModules NXF Cardframe SpecificationsNXF Cardframe Specifications OverviewPosition Rear Panel Components+12 VDC PWR Number NXS-NMS NetModules SpecificationsNXS-NMS NetModules PortMounting modules into an equipment rack NXC-COM2 Dual COM Port Control Card SpecificationsNXC-COM2 Specifications DeviceidNXC-COM2 Programming Information Pinouts and Wiring ConfigurationNXC-COM2 Channel Assignment Ctspsh ChardChardm GET BaudRxoff HsonRxclr RxonXoff NXC-COM2 SendString Escape SequencesTxclr XON27,19,time Command Description 27,18,027,18,1 27,20,0NXC-I/O10 Specifications NXC-I/O10 Input/Output Control CardNXC-I/O10 Pinouts, Signals, and I/O Mode Functions Pinouts, Signals, and I/O Mode FunctionsSetting the Switch/Voltage Mode Jumpers NXC-I/O10 Channel AssignmentsOpen mode setting Setting the Voltage Clamp Jumper +12V or Open+12 V mode setting default Page NXC-IRS4 Specifications NXC-IRS4 4-Port IR/S Control CardProgramming Information Pinouts, Signals, and FunctionsNXC-IRS4 Channel Assignments Ctof CtonPOD GET ModeIroff POFSET Input Link PtofPton SET IO LinkXCH SET ModeMode 1 Example x x x enter XchmCommand Description Xchm Mode 3 Example 100100… xPage Pinouts and Functions NXC-REL10 SpecificationsNXC-REL10 Relay Control Card NXC-REL10 Channel AssignmentsNXC-REL10 Connections/Wiring No Normally openIref NXC-VAI4 SpecificationsNXC-VAI4 Analog Voltage Control Card NXC-VAI4 Channel Assignments NXC-VAI4 Pinouts, Signals, and FunctionsChannel Assignments Channel State FunctionStops voltage ramping on Output 4 at current value Level Description NXC-VAI4 Output Level AssignmentsNXC-VAI4 Output Level Assignments NXC-VAI4 Input Level Assignments NXC-VAI4 SendCommands NXC-VAI4 Input Level Assignments Levoff LevonCurve RateLevel Value Functions. Negative voltages are not valid for Inputs Page NXC-VOL4 Volume Control Card NXC-VOL4 SpecificationsAudio Channel Gain Ratio Jumper Settings NXC-VOL4 Connections/WiringNXC-VOL4 Pinouts, Signals, and Functions NXC-VOL4 Channel Assignments per port NXC-VOL4 Channel AssignmentsNXC-VOL4 Levels NXC-VOL4 LevelsNXC-VOL4 SendCommands SendlevelPage It’s Your World Take Control